Cargando…

pHEMA Encapsulated PEDOT-PSS-CNT Microsphere Microelectrodes for Recording Single Unit Activity in the Brain

The long-term reliability of neural interfaces and stability of high-quality recordings are still unsolved issues in neuroscience research. High surface area PEDOT-PSS-CNT composites are able to greatly improve the performance of recording and stimulation for traditional intracortical metal microele...

Descripción completa

Detalles Bibliográficos
Autores principales: Castagnola, Elisa, Maggiolini, Emma, Ceseracciu, Luca, Ciarpella, Francesca, Zucchini, Elena, De Faveri, Sara, Fadiga, Luciano, Ricci, Davide
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4834343/
https://www.ncbi.nlm.nih.gov/pubmed/27147944
http://dx.doi.org/10.3389/fnins.2016.00151
_version_ 1782427468349571072
author Castagnola, Elisa
Maggiolini, Emma
Ceseracciu, Luca
Ciarpella, Francesca
Zucchini, Elena
De Faveri, Sara
Fadiga, Luciano
Ricci, Davide
author_facet Castagnola, Elisa
Maggiolini, Emma
Ceseracciu, Luca
Ciarpella, Francesca
Zucchini, Elena
De Faveri, Sara
Fadiga, Luciano
Ricci, Davide
author_sort Castagnola, Elisa
collection PubMed
description The long-term reliability of neural interfaces and stability of high-quality recordings are still unsolved issues in neuroscience research. High surface area PEDOT-PSS-CNT composites are able to greatly improve the performance of recording and stimulation for traditional intracortical metal microelectrodes by decreasing their impedance and increasing their charge transfer capability. This enhancement significantly reduces the size of the implantable device though preserving excellent electrical performances. On the other hand, the presence of nanomaterials often rises concerns regarding possible health hazards, especially when considering a clinical application of the devices. For this reason, we decided to explore the problem from a new perspective by designing and testing an innovative device based on nanostructured microspheres grown on a thin tether, integrating PEDOT-PSS-CNT nanocomposites with a soft synthetic permanent biocompatible hydrogel. The pHEMA hydrogel preserves the electrochemical performance and high quality recording ability of PEDOT-PSS-CNT coated devices, reduces the mechanical mismatch between soft brain tissue and stiff devices and also avoids direct contact between the neural tissue and the nanocomposite, by acting as a biocompatible protective barrier against potential nanomaterial detachment. Moreover, the spherical shape of the electrode together with the surface area increase provided by the nanocomposite deposited on it, maximize the electrical contact and may improve recording stability over time. These results have a good potential to contribute to fulfill the grand challenge of obtaining stable neural interfaces for long-term applications.
format Online
Article
Text
id pubmed-4834343
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-48343432016-05-04 pHEMA Encapsulated PEDOT-PSS-CNT Microsphere Microelectrodes for Recording Single Unit Activity in the Brain Castagnola, Elisa Maggiolini, Emma Ceseracciu, Luca Ciarpella, Francesca Zucchini, Elena De Faveri, Sara Fadiga, Luciano Ricci, Davide Front Neurosci Neuroscience The long-term reliability of neural interfaces and stability of high-quality recordings are still unsolved issues in neuroscience research. High surface area PEDOT-PSS-CNT composites are able to greatly improve the performance of recording and stimulation for traditional intracortical metal microelectrodes by decreasing their impedance and increasing their charge transfer capability. This enhancement significantly reduces the size of the implantable device though preserving excellent electrical performances. On the other hand, the presence of nanomaterials often rises concerns regarding possible health hazards, especially when considering a clinical application of the devices. For this reason, we decided to explore the problem from a new perspective by designing and testing an innovative device based on nanostructured microspheres grown on a thin tether, integrating PEDOT-PSS-CNT nanocomposites with a soft synthetic permanent biocompatible hydrogel. The pHEMA hydrogel preserves the electrochemical performance and high quality recording ability of PEDOT-PSS-CNT coated devices, reduces the mechanical mismatch between soft brain tissue and stiff devices and also avoids direct contact between the neural tissue and the nanocomposite, by acting as a biocompatible protective barrier against potential nanomaterial detachment. Moreover, the spherical shape of the electrode together with the surface area increase provided by the nanocomposite deposited on it, maximize the electrical contact and may improve recording stability over time. These results have a good potential to contribute to fulfill the grand challenge of obtaining stable neural interfaces for long-term applications. Frontiers Media S.A. 2016-04-18 /pmc/articles/PMC4834343/ /pubmed/27147944 http://dx.doi.org/10.3389/fnins.2016.00151 Text en Copyright © 2016 Castagnola, Maggiolini, Ceseracciu, Ciarpella, Zucchini, De Faveri, Fadiga and Ricci. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Castagnola, Elisa
Maggiolini, Emma
Ceseracciu, Luca
Ciarpella, Francesca
Zucchini, Elena
De Faveri, Sara
Fadiga, Luciano
Ricci, Davide
pHEMA Encapsulated PEDOT-PSS-CNT Microsphere Microelectrodes for Recording Single Unit Activity in the Brain
title pHEMA Encapsulated PEDOT-PSS-CNT Microsphere Microelectrodes for Recording Single Unit Activity in the Brain
title_full pHEMA Encapsulated PEDOT-PSS-CNT Microsphere Microelectrodes for Recording Single Unit Activity in the Brain
title_fullStr pHEMA Encapsulated PEDOT-PSS-CNT Microsphere Microelectrodes for Recording Single Unit Activity in the Brain
title_full_unstemmed pHEMA Encapsulated PEDOT-PSS-CNT Microsphere Microelectrodes for Recording Single Unit Activity in the Brain
title_short pHEMA Encapsulated PEDOT-PSS-CNT Microsphere Microelectrodes for Recording Single Unit Activity in the Brain
title_sort phema encapsulated pedot-pss-cnt microsphere microelectrodes for recording single unit activity in the brain
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4834343/
https://www.ncbi.nlm.nih.gov/pubmed/27147944
http://dx.doi.org/10.3389/fnins.2016.00151
work_keys_str_mv AT castagnolaelisa phemaencapsulatedpedotpsscntmicrospheremicroelectrodesforrecordingsingleunitactivityinthebrain
AT maggioliniemma phemaencapsulatedpedotpsscntmicrospheremicroelectrodesforrecordingsingleunitactivityinthebrain
AT ceseracciuluca phemaencapsulatedpedotpsscntmicrospheremicroelectrodesforrecordingsingleunitactivityinthebrain
AT ciarpellafrancesca phemaencapsulatedpedotpsscntmicrospheremicroelectrodesforrecordingsingleunitactivityinthebrain
AT zucchinielena phemaencapsulatedpedotpsscntmicrospheremicroelectrodesforrecordingsingleunitactivityinthebrain
AT defaverisara phemaencapsulatedpedotpsscntmicrospheremicroelectrodesforrecordingsingleunitactivityinthebrain
AT fadigaluciano phemaencapsulatedpedotpsscntmicrospheremicroelectrodesforrecordingsingleunitactivityinthebrain
AT riccidavide phemaencapsulatedpedotpsscntmicrospheremicroelectrodesforrecordingsingleunitactivityinthebrain