Cargando…

Right Ventricular Anatomy Can Accommodate Multiple Micra Transcatheter Pacemakers

BACKGROUND: The introduction of transcatheter pacemaker technology has the potential to significantly reduce if not eliminate a number of complications associated with a traditional leaded pacing system. However, this technology raises new questions regarding how to manage the device at end of servi...

Descripción completa

Detalles Bibliográficos
Autores principales: OMDAHL, PAMELA, EGGEN, MICHAEL D., BONNER, MATTHEW D., IAIZZO, PAUL A., WIKA, KENT
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4834726/
https://www.ncbi.nlm.nih.gov/pubmed/26710918
http://dx.doi.org/10.1111/pace.12804
_version_ 1782427531460214784
author OMDAHL, PAMELA
EGGEN, MICHAEL D.
BONNER, MATTHEW D.
IAIZZO, PAUL A.
WIKA, KENT
author_facet OMDAHL, PAMELA
EGGEN, MICHAEL D.
BONNER, MATTHEW D.
IAIZZO, PAUL A.
WIKA, KENT
author_sort OMDAHL, PAMELA
collection PubMed
description BACKGROUND: The introduction of transcatheter pacemaker technology has the potential to significantly reduce if not eliminate a number of complications associated with a traditional leaded pacing system. However, this technology raises new questions regarding how to manage the device at end of service, the number of devices the right ventricle (RV) can accommodate, and what patient age is appropriate for this therapy. In this study, six human cadaver hearts and one reanimated human heart (not deemed viable for transplant) were each implanted with three Micra devices in traditional pacing locations via fluoroscopic imaging. METHODS: A total of six human cadaver hearts were obtained from the University of Minnesota Anatomy Bequest Program; the seventh heart was a heart not deemed viable for transplant obtained from LifeSource and then reanimated using Visible Heart® methodologies. Each heart was implanted with multiple Micras using imaging and proper delivery tools; in these, the right ventricular volumes were measured and recorded. The hearts were subsequently dissected to view the right ventricular anatomies and the positions and spacing between devices. RESULTS: Multiple Micra devices could be placed in each heart in traditional, clinically accepted pacing implant locations within the RV and in each case without physical device interactions. This was true even in a human heart considered to be relatively small. CONCLUSIONS: Although this technology is new, it was demonstrated here that within the human heart's RV, three Micra devices could be accommodated within traditional pacing locations: with the potential in some, for even more.
format Online
Article
Text
id pubmed-4834726
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-48347262016-05-05 Right Ventricular Anatomy Can Accommodate Multiple Micra Transcatheter Pacemakers OMDAHL, PAMELA EGGEN, MICHAEL D. BONNER, MATTHEW D. IAIZZO, PAUL A. WIKA, KENT Pacing Clin Electrophysiol Devices BACKGROUND: The introduction of transcatheter pacemaker technology has the potential to significantly reduce if not eliminate a number of complications associated with a traditional leaded pacing system. However, this technology raises new questions regarding how to manage the device at end of service, the number of devices the right ventricle (RV) can accommodate, and what patient age is appropriate for this therapy. In this study, six human cadaver hearts and one reanimated human heart (not deemed viable for transplant) were each implanted with three Micra devices in traditional pacing locations via fluoroscopic imaging. METHODS: A total of six human cadaver hearts were obtained from the University of Minnesota Anatomy Bequest Program; the seventh heart was a heart not deemed viable for transplant obtained from LifeSource and then reanimated using Visible Heart® methodologies. Each heart was implanted with multiple Micras using imaging and proper delivery tools; in these, the right ventricular volumes were measured and recorded. The hearts were subsequently dissected to view the right ventricular anatomies and the positions and spacing between devices. RESULTS: Multiple Micra devices could be placed in each heart in traditional, clinically accepted pacing implant locations within the RV and in each case without physical device interactions. This was true even in a human heart considered to be relatively small. CONCLUSIONS: Although this technology is new, it was demonstrated here that within the human heart's RV, three Micra devices could be accommodated within traditional pacing locations: with the potential in some, for even more. John Wiley and Sons Inc. 2016-02-01 2016-04 /pmc/articles/PMC4834726/ /pubmed/26710918 http://dx.doi.org/10.1111/pace.12804 Text en © 2015 Medtronic PLC. Pacing and Clinical Electrophysiology published by Wiley Periodicals, Inc. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Devices
OMDAHL, PAMELA
EGGEN, MICHAEL D.
BONNER, MATTHEW D.
IAIZZO, PAUL A.
WIKA, KENT
Right Ventricular Anatomy Can Accommodate Multiple Micra Transcatheter Pacemakers
title Right Ventricular Anatomy Can Accommodate Multiple Micra Transcatheter Pacemakers
title_full Right Ventricular Anatomy Can Accommodate Multiple Micra Transcatheter Pacemakers
title_fullStr Right Ventricular Anatomy Can Accommodate Multiple Micra Transcatheter Pacemakers
title_full_unstemmed Right Ventricular Anatomy Can Accommodate Multiple Micra Transcatheter Pacemakers
title_short Right Ventricular Anatomy Can Accommodate Multiple Micra Transcatheter Pacemakers
title_sort right ventricular anatomy can accommodate multiple micra transcatheter pacemakers
topic Devices
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4834726/
https://www.ncbi.nlm.nih.gov/pubmed/26710918
http://dx.doi.org/10.1111/pace.12804
work_keys_str_mv AT omdahlpamela rightventricularanatomycanaccommodatemultiplemicratranscatheterpacemakers
AT eggenmichaeld rightventricularanatomycanaccommodatemultiplemicratranscatheterpacemakers
AT bonnermatthewd rightventricularanatomycanaccommodatemultiplemicratranscatheterpacemakers
AT iaizzopaula rightventricularanatomycanaccommodatemultiplemicratranscatheterpacemakers
AT wikakent rightventricularanatomycanaccommodatemultiplemicratranscatheterpacemakers