Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. OBJECTIVES: To verify the stress generated on the peri-implant area...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Faculdade De Odontologia De Bauru - USP
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4836917/ https://www.ncbi.nlm.nih.gov/pubmed/27119758 http://dx.doi.org/10.1590/1678-775720150297 |
_version_ | 1782427784881111040 |
---|---|
author | SUEDAM, Valdey MORETTI, Rafael Tobias SOUSA, Edson Antonio Capello RUBO, José Henrique |
author_facet | SUEDAM, Valdey MORETTI, Rafael Tobias SOUSA, Edson Antonio Capello RUBO, José Henrique |
author_sort | SUEDAM, Valdey |
collection | PubMed |
description | Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. OBJECTIVES: To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. MATERIAL AND METHODS: A U-shaped polyurethane model simulating the mandibular bone containing two implants (Ø 3.75 mm) was used. Six groups were formed according to the alloy’s framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the mesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. RESULTS: Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p<0.05) between the groups. Pearson correlation test (p<0.05) was applied showing positive correlations between the increase of the cantilever arm and the deformation of the peri-implant area. CONCLUSIONS: This report demonstrated the CoCr alloy shows larger compression values compared to the PdAg alloy for the same distances of cantilever. The point of load application influences the deformation on the peri-implant area, increasing in accordance with the increase of the lever arm. |
format | Online Article Text |
id | pubmed-4836917 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Faculdade De Odontologia De Bauru - USP |
record_format | MEDLINE/PubMed |
spelling | pubmed-48369172016-04-26 Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures SUEDAM, Valdey MORETTI, Rafael Tobias SOUSA, Edson Antonio Capello RUBO, José Henrique J Appl Oral Sci Original Articles Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. OBJECTIVES: To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. MATERIAL AND METHODS: A U-shaped polyurethane model simulating the mandibular bone containing two implants (Ø 3.75 mm) was used. Six groups were formed according to the alloy’s framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the mesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. RESULTS: Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p<0.05) between the groups. Pearson correlation test (p<0.05) was applied showing positive correlations between the increase of the cantilever arm and the deformation of the peri-implant area. CONCLUSIONS: This report demonstrated the CoCr alloy shows larger compression values compared to the PdAg alloy for the same distances of cantilever. The point of load application influences the deformation on the peri-implant area, increasing in accordance with the increase of the lever arm. Faculdade De Odontologia De Bauru - USP 2016 /pmc/articles/PMC4836917/ /pubmed/27119758 http://dx.doi.org/10.1590/1678-775720150297 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles SUEDAM, Valdey MORETTI, Rafael Tobias SOUSA, Edson Antonio Capello RUBO, José Henrique Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures |
title | Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures |
title_full | Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures |
title_fullStr | Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures |
title_full_unstemmed | Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures |
title_short | Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures |
title_sort | effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4836917/ https://www.ncbi.nlm.nih.gov/pubmed/27119758 http://dx.doi.org/10.1590/1678-775720150297 |
work_keys_str_mv | AT suedamvaldey effectofcantileverlengthandalloyframeworkonthestressdistributioninperiimplantareaofcantileveredimplantsupportedfixedpartialdentures AT morettirafaeltobias effectofcantileverlengthandalloyframeworkonthestressdistributioninperiimplantareaofcantileveredimplantsupportedfixedpartialdentures AT sousaedsonantoniocapello effectofcantileverlengthandalloyframeworkonthestressdistributioninperiimplantareaofcantileveredimplantsupportedfixedpartialdentures AT rubojosehenrique effectofcantileverlengthandalloyframeworkonthestressdistributioninperiimplantareaofcantileveredimplantsupportedfixedpartialdentures |