Cargando…

Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures

Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. OBJECTIVES: To verify the stress generated on the peri-implant area...

Descripción completa

Detalles Bibliográficos
Autores principales: SUEDAM, Valdey, MORETTI, Rafael Tobias, SOUSA, Edson Antonio Capello, RUBO, José Henrique
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculdade De Odontologia De Bauru - USP 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4836917/
https://www.ncbi.nlm.nih.gov/pubmed/27119758
http://dx.doi.org/10.1590/1678-775720150297
_version_ 1782427784881111040
author SUEDAM, Valdey
MORETTI, Rafael Tobias
SOUSA, Edson Antonio Capello
RUBO, José Henrique
author_facet SUEDAM, Valdey
MORETTI, Rafael Tobias
SOUSA, Edson Antonio Capello
RUBO, José Henrique
author_sort SUEDAM, Valdey
collection PubMed
description Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. OBJECTIVES: To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. MATERIAL AND METHODS: A U-shaped polyurethane model simulating the mandibular bone containing two implants (Ø 3.75 mm) was used. Six groups were formed according to the alloy’s framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the mesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. RESULTS: Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p<0.05) between the groups. Pearson correlation test (p<0.05) was applied showing positive correlations between the increase of the cantilever arm and the deformation of the peri-implant area. CONCLUSIONS: This report demonstrated the CoCr alloy shows larger compression values compared to the PdAg alloy for the same distances of cantilever. The point of load application influences the deformation on the peri-implant area, increasing in accordance with the increase of the lever arm.
format Online
Article
Text
id pubmed-4836917
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Faculdade De Odontologia De Bauru - USP
record_format MEDLINE/PubMed
spelling pubmed-48369172016-04-26 Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures SUEDAM, Valdey MORETTI, Rafael Tobias SOUSA, Edson Antonio Capello RUBO, José Henrique J Appl Oral Sci Original Articles Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. OBJECTIVES: To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. MATERIAL AND METHODS: A U-shaped polyurethane model simulating the mandibular bone containing two implants (Ø 3.75 mm) was used. Six groups were formed according to the alloy’s framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the mesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. RESULTS: Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p<0.05) between the groups. Pearson correlation test (p<0.05) was applied showing positive correlations between the increase of the cantilever arm and the deformation of the peri-implant area. CONCLUSIONS: This report demonstrated the CoCr alloy shows larger compression values compared to the PdAg alloy for the same distances of cantilever. The point of load application influences the deformation on the peri-implant area, increasing in accordance with the increase of the lever arm. Faculdade De Odontologia De Bauru - USP 2016 /pmc/articles/PMC4836917/ /pubmed/27119758 http://dx.doi.org/10.1590/1678-775720150297 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
SUEDAM, Valdey
MORETTI, Rafael Tobias
SOUSA, Edson Antonio Capello
RUBO, José Henrique
Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title_full Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title_fullStr Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title_full_unstemmed Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title_short Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title_sort effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4836917/
https://www.ncbi.nlm.nih.gov/pubmed/27119758
http://dx.doi.org/10.1590/1678-775720150297
work_keys_str_mv AT suedamvaldey effectofcantileverlengthandalloyframeworkonthestressdistributioninperiimplantareaofcantileveredimplantsupportedfixedpartialdentures
AT morettirafaeltobias effectofcantileverlengthandalloyframeworkonthestressdistributioninperiimplantareaofcantileveredimplantsupportedfixedpartialdentures
AT sousaedsonantoniocapello effectofcantileverlengthandalloyframeworkonthestressdistributioninperiimplantareaofcantileveredimplantsupportedfixedpartialdentures
AT rubojosehenrique effectofcantileverlengthandalloyframeworkonthestressdistributioninperiimplantareaofcantileveredimplantsupportedfixedpartialdentures