Cargando…
Safety and efficacy of the predictive low glucose management system in the prevention of hypoglycaemia: protocol for randomised controlled home trial to evaluate the Suspend before low function
INTRODUCTION: Innovations with sensor-augmented pump therapy (SAPT) to reduce hypoglycaemia in patients with type 1 diabetes are an ongoing area of research. The predictive low glucose management (PLGM) system incorporates continuous glucose sensor data into an algorithm and suspends basal insulin b...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4838718/ https://www.ncbi.nlm.nih.gov/pubmed/27084290 http://dx.doi.org/10.1136/bmjopen-2016-011589 |
_version_ | 1782428017735237632 |
---|---|
author | Abraham, M B Nicholas, J A Ly, T T Roby, H C Paramalingam, N Fairchild, J King, B R Ambler, G R Cameron, F Davis, E A Jones, T W |
author_facet | Abraham, M B Nicholas, J A Ly, T T Roby, H C Paramalingam, N Fairchild, J King, B R Ambler, G R Cameron, F Davis, E A Jones, T W |
author_sort | Abraham, M B |
collection | PubMed |
description | INTRODUCTION: Innovations with sensor-augmented pump therapy (SAPT) to reduce hypoglycaemia in patients with type 1 diabetes are an ongoing area of research. The predictive low glucose management (PLGM) system incorporates continuous glucose sensor data into an algorithm and suspends basal insulin before the occurrence of hypoglycaemia. The system was evaluated in in-clinic studies, and has informed the parameters of a larger home trial to study its efficacy and safety in real life. METHODS AND ANALYSIS: The aim of this report is to describe the study design and outcome measures for the trial. This is a 6-month, multicentre, randomised controlled home trial to test the PLGM system in children and adolescents with type 1 diabetes. The system is available in the Medtronic MiniMed 640G pump as the ‘Suspend before low’ feature. Following a run-in period, participants are randomised to either the control arm with SAPT alone or the intervention arm with SAPT and Suspend before low. The primary aim of this study is to evaluate the time spent hypoglycaemic (sensor glucose <3.5 mmol/L) with and without the system. The secondary aims are to determine the number of hypoglycaemic events, the time spent hyperglycaemic, and to evaluate safety with ketosis and changes in glycated haemoglobin. The study also aims to assess the changes in counter-regulatory hormone responses to hypoglycaemia evaluated by a hyperinsulinaemic hypoglycaemic clamp in a subgroup of patients with impaired awareness. Validated questionnaires are used to measure the fear of hypoglycaemia and the impact on the quality of life to assess burden of the disease. ETHICS AND DISSEMINATION: Ethics committee permissions were gained from respective Institutional Review boards. The findings of the study will provide high quality evidence of the ability of the system in the prevention of hypoglycaemia in real life. TRIAL REGISTRATION NUMBER: ACTRN12614000510640, Pre-results. |
format | Online Article Text |
id | pubmed-4838718 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-48387182016-04-22 Safety and efficacy of the predictive low glucose management system in the prevention of hypoglycaemia: protocol for randomised controlled home trial to evaluate the Suspend before low function Abraham, M B Nicholas, J A Ly, T T Roby, H C Paramalingam, N Fairchild, J King, B R Ambler, G R Cameron, F Davis, E A Jones, T W BMJ Open Diabetes and Endocrinology INTRODUCTION: Innovations with sensor-augmented pump therapy (SAPT) to reduce hypoglycaemia in patients with type 1 diabetes are an ongoing area of research. The predictive low glucose management (PLGM) system incorporates continuous glucose sensor data into an algorithm and suspends basal insulin before the occurrence of hypoglycaemia. The system was evaluated in in-clinic studies, and has informed the parameters of a larger home trial to study its efficacy and safety in real life. METHODS AND ANALYSIS: The aim of this report is to describe the study design and outcome measures for the trial. This is a 6-month, multicentre, randomised controlled home trial to test the PLGM system in children and adolescents with type 1 diabetes. The system is available in the Medtronic MiniMed 640G pump as the ‘Suspend before low’ feature. Following a run-in period, participants are randomised to either the control arm with SAPT alone or the intervention arm with SAPT and Suspend before low. The primary aim of this study is to evaluate the time spent hypoglycaemic (sensor glucose <3.5 mmol/L) with and without the system. The secondary aims are to determine the number of hypoglycaemic events, the time spent hyperglycaemic, and to evaluate safety with ketosis and changes in glycated haemoglobin. The study also aims to assess the changes in counter-regulatory hormone responses to hypoglycaemia evaluated by a hyperinsulinaemic hypoglycaemic clamp in a subgroup of patients with impaired awareness. Validated questionnaires are used to measure the fear of hypoglycaemia and the impact on the quality of life to assess burden of the disease. ETHICS AND DISSEMINATION: Ethics committee permissions were gained from respective Institutional Review boards. The findings of the study will provide high quality evidence of the ability of the system in the prevention of hypoglycaemia in real life. TRIAL REGISTRATION NUMBER: ACTRN12614000510640, Pre-results. BMJ Publishing Group 2016-04-15 /pmc/articles/PMC4838718/ /pubmed/27084290 http://dx.doi.org/10.1136/bmjopen-2016-011589 Text en Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/ This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
spellingShingle | Diabetes and Endocrinology Abraham, M B Nicholas, J A Ly, T T Roby, H C Paramalingam, N Fairchild, J King, B R Ambler, G R Cameron, F Davis, E A Jones, T W Safety and efficacy of the predictive low glucose management system in the prevention of hypoglycaemia: protocol for randomised controlled home trial to evaluate the Suspend before low function |
title | Safety and efficacy of the predictive low glucose management system in the prevention of hypoglycaemia: protocol for randomised controlled home trial to evaluate the Suspend before low function |
title_full | Safety and efficacy of the predictive low glucose management system in the prevention of hypoglycaemia: protocol for randomised controlled home trial to evaluate the Suspend before low function |
title_fullStr | Safety and efficacy of the predictive low glucose management system in the prevention of hypoglycaemia: protocol for randomised controlled home trial to evaluate the Suspend before low function |
title_full_unstemmed | Safety and efficacy of the predictive low glucose management system in the prevention of hypoglycaemia: protocol for randomised controlled home trial to evaluate the Suspend before low function |
title_short | Safety and efficacy of the predictive low glucose management system in the prevention of hypoglycaemia: protocol for randomised controlled home trial to evaluate the Suspend before low function |
title_sort | safety and efficacy of the predictive low glucose management system in the prevention of hypoglycaemia: protocol for randomised controlled home trial to evaluate the suspend before low function |
topic | Diabetes and Endocrinology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4838718/ https://www.ncbi.nlm.nih.gov/pubmed/27084290 http://dx.doi.org/10.1136/bmjopen-2016-011589 |
work_keys_str_mv | AT abrahammb safetyandefficacyofthepredictivelowglucosemanagementsysteminthepreventionofhypoglycaemiaprotocolforrandomisedcontrolledhometrialtoevaluatethesuspendbeforelowfunction AT nicholasja safetyandefficacyofthepredictivelowglucosemanagementsysteminthepreventionofhypoglycaemiaprotocolforrandomisedcontrolledhometrialtoevaluatethesuspendbeforelowfunction AT lytt safetyandefficacyofthepredictivelowglucosemanagementsysteminthepreventionofhypoglycaemiaprotocolforrandomisedcontrolledhometrialtoevaluatethesuspendbeforelowfunction AT robyhc safetyandefficacyofthepredictivelowglucosemanagementsysteminthepreventionofhypoglycaemiaprotocolforrandomisedcontrolledhometrialtoevaluatethesuspendbeforelowfunction AT paramalingamn safetyandefficacyofthepredictivelowglucosemanagementsysteminthepreventionofhypoglycaemiaprotocolforrandomisedcontrolledhometrialtoevaluatethesuspendbeforelowfunction AT fairchildj safetyandefficacyofthepredictivelowglucosemanagementsysteminthepreventionofhypoglycaemiaprotocolforrandomisedcontrolledhometrialtoevaluatethesuspendbeforelowfunction AT kingbr safetyandefficacyofthepredictivelowglucosemanagementsysteminthepreventionofhypoglycaemiaprotocolforrandomisedcontrolledhometrialtoevaluatethesuspendbeforelowfunction AT amblergr safetyandefficacyofthepredictivelowglucosemanagementsysteminthepreventionofhypoglycaemiaprotocolforrandomisedcontrolledhometrialtoevaluatethesuspendbeforelowfunction AT cameronf safetyandefficacyofthepredictivelowglucosemanagementsysteminthepreventionofhypoglycaemiaprotocolforrandomisedcontrolledhometrialtoevaluatethesuspendbeforelowfunction AT davisea safetyandefficacyofthepredictivelowglucosemanagementsysteminthepreventionofhypoglycaemiaprotocolforrandomisedcontrolledhometrialtoevaluatethesuspendbeforelowfunction AT jonestw safetyandefficacyofthepredictivelowglucosemanagementsysteminthepreventionofhypoglycaemiaprotocolforrandomisedcontrolledhometrialtoevaluatethesuspendbeforelowfunction |