Cargando…
Reproducibility of Kidney Perfusion Measurements With Arterial Spin Labeling at 1.5 Tesla MRI Combined With Semiautomatic Segmentation for Differential Cortical and Medullary Assessment
Magnetic resonance imaging with arterial spin labeling (ASL) is a noninvasive approach to measure organ perfusion. The purpose of this study was to evaluate the reproducibility of ASL kidney perfusion measurements with semiautomatic segmentation, which allows separate quantification of cortical and...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4839924/ https://www.ncbi.nlm.nih.gov/pubmed/26986143 http://dx.doi.org/10.1097/MD.0000000000003083 |
_version_ | 1782428218206191616 |
---|---|
author | Hammon, Matthias Janka, Rolf Siegl, Christian Seuss, Hannes Grosso, Roberto Martirosian, Petros Schmieder, Roland E. Uder, Michael Kistner, Iris |
author_facet | Hammon, Matthias Janka, Rolf Siegl, Christian Seuss, Hannes Grosso, Roberto Martirosian, Petros Schmieder, Roland E. Uder, Michael Kistner, Iris |
author_sort | Hammon, Matthias |
collection | PubMed |
description | Magnetic resonance imaging with arterial spin labeling (ASL) is a noninvasive approach to measure organ perfusion. The purpose of this study was to evaluate the reproducibility of ASL kidney perfusion measurements with semiautomatic segmentation, which allows separate quantification of cortical and medullary perfusion. The right kidneys of 14 healthy volunteers were examined 6 times on 2 occasions (3 times at each occasion). There was a 10-minute pause between each examination and a 14-day interval between the 2 occasions. Cortical, medullary, and whole kidney parenchymal perfusion was determined with customized semiautomatic segmentation software. Coefficient of variances (CVs) and intraclass correlations (ICCs) were calculated. Mean whole, cortical, and medullary kidney perfusion was 307.26 ± 25.65, 337.10 ± 34.83, and 279.61 ± 26.73 mL/min/100 g, respectively. On session 1, mean perfusion for the whole kidney, cortex, and medulla was 307.08 ± 26.91, 336.79 ± 36.54, and 279.60 ± 27.81 mL/min/100 g, respectively, and on session 2, 307.45 ± 24.65, 337.41 ± 33.48, and 279.61 ± 25.94 mL/min/100 g, respectively (P > 0.05; R(2) = 0.60/0.59/0.54). For whole, cortical, and medullary kidney perfusion, the total ICC/CV were 0.97/3.43 ± 0.86%, 0.97/4.19 ± 1.33%, and 0.96/4.12 ± 1.36%, respectively. Measurements did not differ significantly and showed a very good correlation (P > 0.05; R(2) = 0.75/0.76/0.65). ASL kidney measurements combined with operator-independent semiautomatic segmentation revealed high correlation and low variance of cortical, medullary, and whole kidney perfusion. |
format | Online Article Text |
id | pubmed-4839924 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-48399242016-06-02 Reproducibility of Kidney Perfusion Measurements With Arterial Spin Labeling at 1.5 Tesla MRI Combined With Semiautomatic Segmentation for Differential Cortical and Medullary Assessment Hammon, Matthias Janka, Rolf Siegl, Christian Seuss, Hannes Grosso, Roberto Martirosian, Petros Schmieder, Roland E. Uder, Michael Kistner, Iris Medicine (Baltimore) 6800 Magnetic resonance imaging with arterial spin labeling (ASL) is a noninvasive approach to measure organ perfusion. The purpose of this study was to evaluate the reproducibility of ASL kidney perfusion measurements with semiautomatic segmentation, which allows separate quantification of cortical and medullary perfusion. The right kidneys of 14 healthy volunteers were examined 6 times on 2 occasions (3 times at each occasion). There was a 10-minute pause between each examination and a 14-day interval between the 2 occasions. Cortical, medullary, and whole kidney parenchymal perfusion was determined with customized semiautomatic segmentation software. Coefficient of variances (CVs) and intraclass correlations (ICCs) were calculated. Mean whole, cortical, and medullary kidney perfusion was 307.26 ± 25.65, 337.10 ± 34.83, and 279.61 ± 26.73 mL/min/100 g, respectively. On session 1, mean perfusion for the whole kidney, cortex, and medulla was 307.08 ± 26.91, 336.79 ± 36.54, and 279.60 ± 27.81 mL/min/100 g, respectively, and on session 2, 307.45 ± 24.65, 337.41 ± 33.48, and 279.61 ± 25.94 mL/min/100 g, respectively (P > 0.05; R(2) = 0.60/0.59/0.54). For whole, cortical, and medullary kidney perfusion, the total ICC/CV were 0.97/3.43 ± 0.86%, 0.97/4.19 ± 1.33%, and 0.96/4.12 ± 1.36%, respectively. Measurements did not differ significantly and showed a very good correlation (P > 0.05; R(2) = 0.75/0.76/0.65). ASL kidney measurements combined with operator-independent semiautomatic segmentation revealed high correlation and low variance of cortical, medullary, and whole kidney perfusion. Wolters Kluwer Health 2016-03-18 /pmc/articles/PMC4839924/ /pubmed/26986143 http://dx.doi.org/10.1097/MD.0000000000003083 Text en Copyright © 2016 Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 |
spellingShingle | 6800 Hammon, Matthias Janka, Rolf Siegl, Christian Seuss, Hannes Grosso, Roberto Martirosian, Petros Schmieder, Roland E. Uder, Michael Kistner, Iris Reproducibility of Kidney Perfusion Measurements With Arterial Spin Labeling at 1.5 Tesla MRI Combined With Semiautomatic Segmentation for Differential Cortical and Medullary Assessment |
title | Reproducibility of Kidney Perfusion Measurements With Arterial Spin Labeling at 1.5 Tesla MRI Combined With Semiautomatic Segmentation for Differential Cortical and Medullary Assessment |
title_full | Reproducibility of Kidney Perfusion Measurements With Arterial Spin Labeling at 1.5 Tesla MRI Combined With Semiautomatic Segmentation for Differential Cortical and Medullary Assessment |
title_fullStr | Reproducibility of Kidney Perfusion Measurements With Arterial Spin Labeling at 1.5 Tesla MRI Combined With Semiautomatic Segmentation for Differential Cortical and Medullary Assessment |
title_full_unstemmed | Reproducibility of Kidney Perfusion Measurements With Arterial Spin Labeling at 1.5 Tesla MRI Combined With Semiautomatic Segmentation for Differential Cortical and Medullary Assessment |
title_short | Reproducibility of Kidney Perfusion Measurements With Arterial Spin Labeling at 1.5 Tesla MRI Combined With Semiautomatic Segmentation for Differential Cortical and Medullary Assessment |
title_sort | reproducibility of kidney perfusion measurements with arterial spin labeling at 1.5 tesla mri combined with semiautomatic segmentation for differential cortical and medullary assessment |
topic | 6800 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4839924/ https://www.ncbi.nlm.nih.gov/pubmed/26986143 http://dx.doi.org/10.1097/MD.0000000000003083 |
work_keys_str_mv | AT hammonmatthias reproducibilityofkidneyperfusionmeasurementswitharterialspinlabelingat15teslamricombinedwithsemiautomaticsegmentationfordifferentialcorticalandmedullaryassessment AT jankarolf reproducibilityofkidneyperfusionmeasurementswitharterialspinlabelingat15teslamricombinedwithsemiautomaticsegmentationfordifferentialcorticalandmedullaryassessment AT sieglchristian reproducibilityofkidneyperfusionmeasurementswitharterialspinlabelingat15teslamricombinedwithsemiautomaticsegmentationfordifferentialcorticalandmedullaryassessment AT seusshannes reproducibilityofkidneyperfusionmeasurementswitharterialspinlabelingat15teslamricombinedwithsemiautomaticsegmentationfordifferentialcorticalandmedullaryassessment AT grossoroberto reproducibilityofkidneyperfusionmeasurementswitharterialspinlabelingat15teslamricombinedwithsemiautomaticsegmentationfordifferentialcorticalandmedullaryassessment AT martirosianpetros reproducibilityofkidneyperfusionmeasurementswitharterialspinlabelingat15teslamricombinedwithsemiautomaticsegmentationfordifferentialcorticalandmedullaryassessment AT schmiederrolande reproducibilityofkidneyperfusionmeasurementswitharterialspinlabelingat15teslamricombinedwithsemiautomaticsegmentationfordifferentialcorticalandmedullaryassessment AT udermichael reproducibilityofkidneyperfusionmeasurementswitharterialspinlabelingat15teslamricombinedwithsemiautomaticsegmentationfordifferentialcorticalandmedullaryassessment AT kistneriris reproducibilityofkidneyperfusionmeasurementswitharterialspinlabelingat15teslamricombinedwithsemiautomaticsegmentationfordifferentialcorticalandmedullaryassessment |