Cargando…

Stimulation artifact correction method for estimation of early cortico-cortical evoked potentials

BACKGROUND: Effective connectivity can be explored using direct electrical stimulations in patients suffering from drug-resistant focal epilepsies and investigated with intracranial electrodes. Responses to brief electrical pulses mimic the physiological propagation of signals and manifest as cortic...

Descripción completa

Detalles Bibliográficos
Autores principales: Trebaul, Lena, Rudrauf, David, Job, Anne-Sophie, Mălîia, Mihai Dragos, Popa, Irina, Barborica, Andrei, Minotti, Lorella, Mîndruţă, Ioana, Kahane, Philippe, David, Olivier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier/North-Holland Biomedical Press 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4840016/
https://www.ncbi.nlm.nih.gov/pubmed/26952846
http://dx.doi.org/10.1016/j.jneumeth.2016.03.002
_version_ 1782428227964239872
author Trebaul, Lena
Rudrauf, David
Job, Anne-Sophie
Mălîia, Mihai Dragos
Popa, Irina
Barborica, Andrei
Minotti, Lorella
Mîndruţă, Ioana
Kahane, Philippe
David, Olivier
author_facet Trebaul, Lena
Rudrauf, David
Job, Anne-Sophie
Mălîia, Mihai Dragos
Popa, Irina
Barborica, Andrei
Minotti, Lorella
Mîndruţă, Ioana
Kahane, Philippe
David, Olivier
author_sort Trebaul, Lena
collection PubMed
description BACKGROUND: Effective connectivity can be explored using direct electrical stimulations in patients suffering from drug-resistant focal epilepsies and investigated with intracranial electrodes. Responses to brief electrical pulses mimic the physiological propagation of signals and manifest as cortico-cortical evoked potentials (CCEP). The first CCEP component is believed to reflect direct connectivity with the stimulated region but the stimulation artifact, a sharp deflection occurring during a few milliseconds, frequently contaminates it. NEW METHOD: In order to recover the characteristics of early CCEP responses, we developed an artifact correction method based on electrical modeling of the electrode–tissue interface. The biophysically motivated artifact templates are then regressed out of the recorded data as in any classical template-matching removal artifact methods. RESULTS: Our approach is able to make the distinction between the physiological responses time-locked to the stimulation pulses and the non-physiological component. We tested the correction on simulated CCEP data in order to quantify its efficiency for different stimulation and recording parameters. We demonstrated the efficiency of the new correction method on simulations of single trial recordings for early responses contaminated with the stimulation artifact. The results highlight the importance of sampling frequency for an accurate analysis of CCEP. We then applied the approach to experimental data. COMPARISON WITH EXISTING METHOD: The model-based template removal was compared to a correction based on the subtraction of the averaged artifact. CONCLUSIONS: This new correction method of stimulation artifact will enable investigators to better analyze early CCEP components and infer direct effective connectivity in future CCEP studies.
format Online
Article
Text
id pubmed-4840016
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier/North-Holland Biomedical Press
record_format MEDLINE/PubMed
spelling pubmed-48400162016-05-02 Stimulation artifact correction method for estimation of early cortico-cortical evoked potentials Trebaul, Lena Rudrauf, David Job, Anne-Sophie Mălîia, Mihai Dragos Popa, Irina Barborica, Andrei Minotti, Lorella Mîndruţă, Ioana Kahane, Philippe David, Olivier J Neurosci Methods Article BACKGROUND: Effective connectivity can be explored using direct electrical stimulations in patients suffering from drug-resistant focal epilepsies and investigated with intracranial electrodes. Responses to brief electrical pulses mimic the physiological propagation of signals and manifest as cortico-cortical evoked potentials (CCEP). The first CCEP component is believed to reflect direct connectivity with the stimulated region but the stimulation artifact, a sharp deflection occurring during a few milliseconds, frequently contaminates it. NEW METHOD: In order to recover the characteristics of early CCEP responses, we developed an artifact correction method based on electrical modeling of the electrode–tissue interface. The biophysically motivated artifact templates are then regressed out of the recorded data as in any classical template-matching removal artifact methods. RESULTS: Our approach is able to make the distinction between the physiological responses time-locked to the stimulation pulses and the non-physiological component. We tested the correction on simulated CCEP data in order to quantify its efficiency for different stimulation and recording parameters. We demonstrated the efficiency of the new correction method on simulations of single trial recordings for early responses contaminated with the stimulation artifact. The results highlight the importance of sampling frequency for an accurate analysis of CCEP. We then applied the approach to experimental data. COMPARISON WITH EXISTING METHOD: The model-based template removal was compared to a correction based on the subtraction of the averaged artifact. CONCLUSIONS: This new correction method of stimulation artifact will enable investigators to better analyze early CCEP components and infer direct effective connectivity in future CCEP studies. Elsevier/North-Holland Biomedical Press 2016-05-01 /pmc/articles/PMC4840016/ /pubmed/26952846 http://dx.doi.org/10.1016/j.jneumeth.2016.03.002 Text en © 2016 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Trebaul, Lena
Rudrauf, David
Job, Anne-Sophie
Mălîia, Mihai Dragos
Popa, Irina
Barborica, Andrei
Minotti, Lorella
Mîndruţă, Ioana
Kahane, Philippe
David, Olivier
Stimulation artifact correction method for estimation of early cortico-cortical evoked potentials
title Stimulation artifact correction method for estimation of early cortico-cortical evoked potentials
title_full Stimulation artifact correction method for estimation of early cortico-cortical evoked potentials
title_fullStr Stimulation artifact correction method for estimation of early cortico-cortical evoked potentials
title_full_unstemmed Stimulation artifact correction method for estimation of early cortico-cortical evoked potentials
title_short Stimulation artifact correction method for estimation of early cortico-cortical evoked potentials
title_sort stimulation artifact correction method for estimation of early cortico-cortical evoked potentials
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4840016/
https://www.ncbi.nlm.nih.gov/pubmed/26952846
http://dx.doi.org/10.1016/j.jneumeth.2016.03.002
work_keys_str_mv AT trebaullena stimulationartifactcorrectionmethodforestimationofearlycorticocorticalevokedpotentials
AT rudraufdavid stimulationartifactcorrectionmethodforestimationofearlycorticocorticalevokedpotentials
AT jobannesophie stimulationartifactcorrectionmethodforestimationofearlycorticocorticalevokedpotentials
AT maliiamihaidragos stimulationartifactcorrectionmethodforestimationofearlycorticocorticalevokedpotentials
AT popairina stimulationartifactcorrectionmethodforestimationofearlycorticocorticalevokedpotentials
AT barboricaandrei stimulationartifactcorrectionmethodforestimationofearlycorticocorticalevokedpotentials
AT minottilorella stimulationartifactcorrectionmethodforestimationofearlycorticocorticalevokedpotentials
AT mindrutaioana stimulationartifactcorrectionmethodforestimationofearlycorticocorticalevokedpotentials
AT kahanephilippe stimulationartifactcorrectionmethodforestimationofearlycorticocorticalevokedpotentials
AT davidolivier stimulationartifactcorrectionmethodforestimationofearlycorticocorticalevokedpotentials