Cargando…

End-tidal carbon dioxide variation after a 100- and a 500-ml fluid challenge to assess fluid responsiveness

BACKGROUND: EtCO(2) variation has been advocated replacing cardiac output measurements to evaluate fluid responsiveness (FR) during sepsis. The ability of EtCO(2) variation after a fluid challenge to detect FR in the context of general anaesthesia has not been investigated. Forty patients were prosp...

Descripción completa

Detalles Bibliográficos
Autores principales: Jacquet-Lagrèze, Matthias, Baudin, Florent, David, Jean Stéphane, Fellahi, Jean-Luc, Hu, Patrick B., Lilot, Marc, Piriou, Vincent
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Paris 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4840128/
https://www.ncbi.nlm.nih.gov/pubmed/27101829
http://dx.doi.org/10.1186/s13613-016-0141-9
_version_ 1782428234782081024
author Jacquet-Lagrèze, Matthias
Baudin, Florent
David, Jean Stéphane
Fellahi, Jean-Luc
Hu, Patrick B.
Lilot, Marc
Piriou, Vincent
author_facet Jacquet-Lagrèze, Matthias
Baudin, Florent
David, Jean Stéphane
Fellahi, Jean-Luc
Hu, Patrick B.
Lilot, Marc
Piriou, Vincent
author_sort Jacquet-Lagrèze, Matthias
collection PubMed
description BACKGROUND: EtCO(2) variation has been advocated replacing cardiac output measurements to evaluate fluid responsiveness (FR) during sepsis. The ability of EtCO(2) variation after a fluid challenge to detect FR in the context of general anaesthesia has not been investigated. Forty patients were prospectively studied. They underwent general anaesthesia for major surgeries. CO was measured by transoesophageal Doppler, and EtCO(2) was recorded as well as other haemodynamic parameters [heart rate (HR), mean arterial pressure (MAP), pulse pressure (PP)] at baseline, after 100-ml fluid load over 1 min, and at the end of the 500-ml fluid load. We measured the variation of EtCO(2) at 100 (ΔEtCO(2)100) and 500 ml (ΔEtCO(2)500), and ROC curves were generated. A threshold for ΔEtCO(2) to predict FR was determined with receiver operating curves (ROC) analysis. The primary end point was the ability of EtCO(2) variation after a 500-ml fluid load to diagnose FR. RESULTS: Fifteen patients (38 %) were fluid responders. ROC analysis showed that for a threshold of 5.8 % (ΔEtCO(2)500), sensitivity was 0.6 IC 95 % [0.33; 0.86] and specificity was 1.0 IC 95 % [1.0; 1.0]. An absolute increase of more than 2 mmHg of EtCO(2) is specific to diagnose fluid responsiveness (spe = 96 [88–100] %, sens = 60 [33–88] %, AUC = 0.80 [0.96–0.65]). HR, MAP, and PP variations and ΔEtCO(2)100 did not bring information to predict or diagnose FR. During fluid challenge, the correlation between CI variation and EtCO(2) variation was r = 0.566, p < 0.001. CONCLUSIONS: During surgery, when alveolar ventilation and CO(2) production are constant, ΔEtCO(2)500 is fairly reliable to assess FR. When the variation of EtCO(2) is >5.8 %, all patients were responders, but no conclusion could be done when this variation was <5.8 %. ΔEtCO(2)100 failed to predict FR. Trial registration CPP Lyon Sud Est III ref: 2013-027 B, Number ID RCB: 2013-A00729-36 delivered by the ANSM).
format Online
Article
Text
id pubmed-4840128
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Paris
record_format MEDLINE/PubMed
spelling pubmed-48401282016-05-16 End-tidal carbon dioxide variation after a 100- and a 500-ml fluid challenge to assess fluid responsiveness Jacquet-Lagrèze, Matthias Baudin, Florent David, Jean Stéphane Fellahi, Jean-Luc Hu, Patrick B. Lilot, Marc Piriou, Vincent Ann Intensive Care Research BACKGROUND: EtCO(2) variation has been advocated replacing cardiac output measurements to evaluate fluid responsiveness (FR) during sepsis. The ability of EtCO(2) variation after a fluid challenge to detect FR in the context of general anaesthesia has not been investigated. Forty patients were prospectively studied. They underwent general anaesthesia for major surgeries. CO was measured by transoesophageal Doppler, and EtCO(2) was recorded as well as other haemodynamic parameters [heart rate (HR), mean arterial pressure (MAP), pulse pressure (PP)] at baseline, after 100-ml fluid load over 1 min, and at the end of the 500-ml fluid load. We measured the variation of EtCO(2) at 100 (ΔEtCO(2)100) and 500 ml (ΔEtCO(2)500), and ROC curves were generated. A threshold for ΔEtCO(2) to predict FR was determined with receiver operating curves (ROC) analysis. The primary end point was the ability of EtCO(2) variation after a 500-ml fluid load to diagnose FR. RESULTS: Fifteen patients (38 %) were fluid responders. ROC analysis showed that for a threshold of 5.8 % (ΔEtCO(2)500), sensitivity was 0.6 IC 95 % [0.33; 0.86] and specificity was 1.0 IC 95 % [1.0; 1.0]. An absolute increase of more than 2 mmHg of EtCO(2) is specific to diagnose fluid responsiveness (spe = 96 [88–100] %, sens = 60 [33–88] %, AUC = 0.80 [0.96–0.65]). HR, MAP, and PP variations and ΔEtCO(2)100 did not bring information to predict or diagnose FR. During fluid challenge, the correlation between CI variation and EtCO(2) variation was r = 0.566, p < 0.001. CONCLUSIONS: During surgery, when alveolar ventilation and CO(2) production are constant, ΔEtCO(2)500 is fairly reliable to assess FR. When the variation of EtCO(2) is >5.8 %, all patients were responders, but no conclusion could be done when this variation was <5.8 %. ΔEtCO(2)100 failed to predict FR. Trial registration CPP Lyon Sud Est III ref: 2013-027 B, Number ID RCB: 2013-A00729-36 delivered by the ANSM). Springer Paris 2016-04-22 /pmc/articles/PMC4840128/ /pubmed/27101829 http://dx.doi.org/10.1186/s13613-016-0141-9 Text en © Jacquet-Lagrèze et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Jacquet-Lagrèze, Matthias
Baudin, Florent
David, Jean Stéphane
Fellahi, Jean-Luc
Hu, Patrick B.
Lilot, Marc
Piriou, Vincent
End-tidal carbon dioxide variation after a 100- and a 500-ml fluid challenge to assess fluid responsiveness
title End-tidal carbon dioxide variation after a 100- and a 500-ml fluid challenge to assess fluid responsiveness
title_full End-tidal carbon dioxide variation after a 100- and a 500-ml fluid challenge to assess fluid responsiveness
title_fullStr End-tidal carbon dioxide variation after a 100- and a 500-ml fluid challenge to assess fluid responsiveness
title_full_unstemmed End-tidal carbon dioxide variation after a 100- and a 500-ml fluid challenge to assess fluid responsiveness
title_short End-tidal carbon dioxide variation after a 100- and a 500-ml fluid challenge to assess fluid responsiveness
title_sort end-tidal carbon dioxide variation after a 100- and a 500-ml fluid challenge to assess fluid responsiveness
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4840128/
https://www.ncbi.nlm.nih.gov/pubmed/27101829
http://dx.doi.org/10.1186/s13613-016-0141-9
work_keys_str_mv AT jacquetlagrezematthias endtidalcarbondioxidevariationaftera100anda500mlfluidchallengetoassessfluidresponsiveness
AT baudinflorent endtidalcarbondioxidevariationaftera100anda500mlfluidchallengetoassessfluidresponsiveness
AT davidjeanstephane endtidalcarbondioxidevariationaftera100anda500mlfluidchallengetoassessfluidresponsiveness
AT fellahijeanluc endtidalcarbondioxidevariationaftera100anda500mlfluidchallengetoassessfluidresponsiveness
AT hupatrickb endtidalcarbondioxidevariationaftera100anda500mlfluidchallengetoassessfluidresponsiveness
AT lilotmarc endtidalcarbondioxidevariationaftera100anda500mlfluidchallengetoassessfluidresponsiveness
AT piriouvincent endtidalcarbondioxidevariationaftera100anda500mlfluidchallengetoassessfluidresponsiveness