Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification
BACKGROUND: Integrated PET/MRI with hyperpolarized (13)C magnetic resonance spectroscopic imaging ((13)C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4840180/ https://www.ncbi.nlm.nih.gov/pubmed/27102632 http://dx.doi.org/10.1186/s40658-016-0143-6 |
_version_ | 1782428238227701760 |
---|---|
author | Hansen, Adam E. Andersen, Flemming L. Henriksen, Sarah T. Vignaud, Alexandre Ardenkjaer-Larsen, Jan H. Højgaard, Liselotte Kjaer, Andreas Klausen, Thomas L. |
author_facet | Hansen, Adam E. Andersen, Flemming L. Henriksen, Sarah T. Vignaud, Alexandre Ardenkjaer-Larsen, Jan H. Højgaard, Liselotte Kjaer, Andreas Klausen, Thomas L. |
author_sort | Hansen, Adam E. |
collection | PubMed |
description | BACKGROUND: Integrated PET/MRI with hyperpolarized (13)C magnetic resonance spectroscopic imaging ((13)C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented for a clinical whole-body system using simultaneous (1)H-MRI and PET but never for (13)C-MRSI and PET. Here, the feasibility of simultaneous PET and (13)C-MRSI as well as hyperpolarized (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is evaluated using phantom experiments. METHODS: Combined PET and (13)C-MRSI phantoms including a NEMA [(18)F]-FDG phantom, (13)C-acetate and (13)C-urea sources, and hyperpolarized (13)C-pyruvate were imaged repeatedly with PET and/or (13)C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET trues; and (13)C-MRSI signal-to-noise ratio (SNR) for urea and acetate phantoms. Differences between measurement conditions were evaluated using t tests. RESULTS: PET and (13)C-MRSI data acquisition could be performed simultaneously without any discernible artifacts. The average difference in PET activity between acquisitions with and without simultaneous (13)C-MRSI was 0.83 (largest sphere) and −0.76 % (background). The average difference in net trues was −0.01 %. The average difference in (13)C-MRSI SNR between acquisitions with and without simultaneous PET ranged from −2.28 to 1.21 % for all phantoms and measurement conditions. No differences were significant. The system was capable of (13)C-MRSI of hyperpolarized (13)C-pyruvate. CONCLUSIONS: Simultaneous PET and (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is feasible. Phantom experiments showed that possible interference effects introduced by acquiring data from the two modalities simultaneously are small and non-significant. Further experiments can now investigate the benefits of simultaneous PET and hyperpolarized (13)C-MRI in vivo studies. |
format | Online Article Text |
id | pubmed-4840180 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-48401802016-05-16 Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification Hansen, Adam E. Andersen, Flemming L. Henriksen, Sarah T. Vignaud, Alexandre Ardenkjaer-Larsen, Jan H. Højgaard, Liselotte Kjaer, Andreas Klausen, Thomas L. EJNMMI Phys Original Research BACKGROUND: Integrated PET/MRI with hyperpolarized (13)C magnetic resonance spectroscopic imaging ((13)C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented for a clinical whole-body system using simultaneous (1)H-MRI and PET but never for (13)C-MRSI and PET. Here, the feasibility of simultaneous PET and (13)C-MRSI as well as hyperpolarized (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is evaluated using phantom experiments. METHODS: Combined PET and (13)C-MRSI phantoms including a NEMA [(18)F]-FDG phantom, (13)C-acetate and (13)C-urea sources, and hyperpolarized (13)C-pyruvate were imaged repeatedly with PET and/or (13)C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET trues; and (13)C-MRSI signal-to-noise ratio (SNR) for urea and acetate phantoms. Differences between measurement conditions were evaluated using t tests. RESULTS: PET and (13)C-MRSI data acquisition could be performed simultaneously without any discernible artifacts. The average difference in PET activity between acquisitions with and without simultaneous (13)C-MRSI was 0.83 (largest sphere) and −0.76 % (background). The average difference in net trues was −0.01 %. The average difference in (13)C-MRSI SNR between acquisitions with and without simultaneous PET ranged from −2.28 to 1.21 % for all phantoms and measurement conditions. No differences were significant. The system was capable of (13)C-MRSI of hyperpolarized (13)C-pyruvate. CONCLUSIONS: Simultaneous PET and (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is feasible. Phantom experiments showed that possible interference effects introduced by acquiring data from the two modalities simultaneously are small and non-significant. Further experiments can now investigate the benefits of simultaneous PET and hyperpolarized (13)C-MRI in vivo studies. Springer International Publishing 2016-04-22 /pmc/articles/PMC4840180/ /pubmed/27102632 http://dx.doi.org/10.1186/s40658-016-0143-6 Text en © Hansen et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Research Hansen, Adam E. Andersen, Flemming L. Henriksen, Sarah T. Vignaud, Alexandre Ardenkjaer-Larsen, Jan H. Højgaard, Liselotte Kjaer, Andreas Klausen, Thomas L. Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification |
title | Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification |
title_full | Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification |
title_fullStr | Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification |
title_full_unstemmed | Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification |
title_short | Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification |
title_sort | simultaneous pet/mri with (13)c magnetic resonance spectroscopic imaging (hyperpet): phantom-based evaluation of pet quantification |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4840180/ https://www.ncbi.nlm.nih.gov/pubmed/27102632 http://dx.doi.org/10.1186/s40658-016-0143-6 |
work_keys_str_mv | AT hansenadame simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification AT andersenflemmingl simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification AT henriksensaraht simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification AT vignaudalexandre simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification AT ardenkjaerlarsenjanh simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification AT højgaardliselotte simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification AT kjaerandreas simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification AT klausenthomasl simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification |