Cargando…

Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification

BACKGROUND: Integrated PET/MRI with hyperpolarized (13)C magnetic resonance spectroscopic imaging ((13)C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented...

Descripción completa

Detalles Bibliográficos
Autores principales: Hansen, Adam E., Andersen, Flemming L., Henriksen, Sarah T., Vignaud, Alexandre, Ardenkjaer-Larsen, Jan H., Højgaard, Liselotte, Kjaer, Andreas, Klausen, Thomas L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4840180/
https://www.ncbi.nlm.nih.gov/pubmed/27102632
http://dx.doi.org/10.1186/s40658-016-0143-6
_version_ 1782428238227701760
author Hansen, Adam E.
Andersen, Flemming L.
Henriksen, Sarah T.
Vignaud, Alexandre
Ardenkjaer-Larsen, Jan H.
Højgaard, Liselotte
Kjaer, Andreas
Klausen, Thomas L.
author_facet Hansen, Adam E.
Andersen, Flemming L.
Henriksen, Sarah T.
Vignaud, Alexandre
Ardenkjaer-Larsen, Jan H.
Højgaard, Liselotte
Kjaer, Andreas
Klausen, Thomas L.
author_sort Hansen, Adam E.
collection PubMed
description BACKGROUND: Integrated PET/MRI with hyperpolarized (13)C magnetic resonance spectroscopic imaging ((13)C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented for a clinical whole-body system using simultaneous (1)H-MRI and PET but never for (13)C-MRSI and PET. Here, the feasibility of simultaneous PET and (13)C-MRSI as well as hyperpolarized (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is evaluated using phantom experiments. METHODS: Combined PET and (13)C-MRSI phantoms including a NEMA [(18)F]-FDG phantom, (13)C-acetate and (13)C-urea sources, and hyperpolarized (13)C-pyruvate were imaged repeatedly with PET and/or (13)C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET trues; and (13)C-MRSI signal-to-noise ratio (SNR) for urea and acetate phantoms. Differences between measurement conditions were evaluated using t tests. RESULTS: PET and (13)C-MRSI data acquisition could be performed simultaneously without any discernible artifacts. The average difference in PET activity between acquisitions with and without simultaneous (13)C-MRSI was 0.83 (largest sphere) and −0.76 % (background). The average difference in net trues was −0.01 %. The average difference in (13)C-MRSI SNR between acquisitions with and without simultaneous PET ranged from −2.28 to 1.21 % for all phantoms and measurement conditions. No differences were significant. The system was capable of (13)C-MRSI of hyperpolarized (13)C-pyruvate. CONCLUSIONS: Simultaneous PET and (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is feasible. Phantom experiments showed that possible interference effects introduced by acquiring data from the two modalities simultaneously are small and non-significant. Further experiments can now investigate the benefits of simultaneous PET and hyperpolarized (13)C-MRI in vivo studies.
format Online
Article
Text
id pubmed-4840180
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-48401802016-05-16 Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification Hansen, Adam E. Andersen, Flemming L. Henriksen, Sarah T. Vignaud, Alexandre Ardenkjaer-Larsen, Jan H. Højgaard, Liselotte Kjaer, Andreas Klausen, Thomas L. EJNMMI Phys Original Research BACKGROUND: Integrated PET/MRI with hyperpolarized (13)C magnetic resonance spectroscopic imaging ((13)C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented for a clinical whole-body system using simultaneous (1)H-MRI and PET but never for (13)C-MRSI and PET. Here, the feasibility of simultaneous PET and (13)C-MRSI as well as hyperpolarized (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is evaluated using phantom experiments. METHODS: Combined PET and (13)C-MRSI phantoms including a NEMA [(18)F]-FDG phantom, (13)C-acetate and (13)C-urea sources, and hyperpolarized (13)C-pyruvate were imaged repeatedly with PET and/or (13)C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET trues; and (13)C-MRSI signal-to-noise ratio (SNR) for urea and acetate phantoms. Differences between measurement conditions were evaluated using t tests. RESULTS: PET and (13)C-MRSI data acquisition could be performed simultaneously without any discernible artifacts. The average difference in PET activity between acquisitions with and without simultaneous (13)C-MRSI was 0.83 (largest sphere) and −0.76 % (background). The average difference in net trues was −0.01 %. The average difference in (13)C-MRSI SNR between acquisitions with and without simultaneous PET ranged from −2.28 to 1.21 % for all phantoms and measurement conditions. No differences were significant. The system was capable of (13)C-MRSI of hyperpolarized (13)C-pyruvate. CONCLUSIONS: Simultaneous PET and (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is feasible. Phantom experiments showed that possible interference effects introduced by acquiring data from the two modalities simultaneously are small and non-significant. Further experiments can now investigate the benefits of simultaneous PET and hyperpolarized (13)C-MRI in vivo studies. Springer International Publishing 2016-04-22 /pmc/articles/PMC4840180/ /pubmed/27102632 http://dx.doi.org/10.1186/s40658-016-0143-6 Text en © Hansen et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Hansen, Adam E.
Andersen, Flemming L.
Henriksen, Sarah T.
Vignaud, Alexandre
Ardenkjaer-Larsen, Jan H.
Højgaard, Liselotte
Kjaer, Andreas
Klausen, Thomas L.
Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification
title Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification
title_full Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification
title_fullStr Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification
title_full_unstemmed Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification
title_short Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification
title_sort simultaneous pet/mri with (13)c magnetic resonance spectroscopic imaging (hyperpet): phantom-based evaluation of pet quantification
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4840180/
https://www.ncbi.nlm.nih.gov/pubmed/27102632
http://dx.doi.org/10.1186/s40658-016-0143-6
work_keys_str_mv AT hansenadame simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification
AT andersenflemmingl simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification
AT henriksensaraht simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification
AT vignaudalexandre simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification
AT ardenkjaerlarsenjanh simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification
AT højgaardliselotte simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification
AT kjaerandreas simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification
AT klausenthomasl simultaneouspetmriwith13cmagneticresonancespectroscopicimaginghyperpetphantombasedevaluationofpetquantification