Cargando…
Cone-Beam Computed Tomography Assessment of Root Canal Transportation by Neoniti and Reciproc Single-File Systems
INTRODUCTION: The aim of this in vitro study was to compare the canal transportation of two single-file engine-driven systems, Neoniti and Reciproc, using cone-beam computed tomography (CBCT). METHODS AND MATERIALS: Forty-five non-calcified roots with mature apices and apical curvature of 15-30 degr...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Iranian Center for Endodontic Research
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4841342/ https://www.ncbi.nlm.nih.gov/pubmed/27141215 http://dx.doi.org/10.7508/iej.2016.02.004 |
_version_ | 1782428376910266368 |
---|---|
author | Moazzami, Fariborz Khojastepour, Leila Nabavizadeh, Mohammadreza Seied Habashi, Mina |
author_facet | Moazzami, Fariborz Khojastepour, Leila Nabavizadeh, Mohammadreza Seied Habashi, Mina |
author_sort | Moazzami, Fariborz |
collection | PubMed |
description | INTRODUCTION: The aim of this in vitro study was to compare the canal transportation of two single-file engine-driven systems, Neoniti and Reciproc, using cone-beam computed tomography (CBCT). METHODS AND MATERIALS: Forty-five non-calcified roots with mature apices and apical curvature of 15-30 degrees were selected from extracted human maxillary molars for this study. Samples were randomly divided into two groups (n=20) and a control group (n=5) and canal preparation with either system was performed according to manufacturers' instructions. Pre- and post-instrumentation CBCT images were captured and the amount of canal transportation within the files was calculated at levels of 3, 4, and 5 mm from the apex. The independent sample t-test was used to analyze the statistical significance between the two groups. The level of significance was defined at 0.05. RESULTS: Reciproc created more canal transportation compared to Neoniti in both mesiodistal and buccolingual directions. The difference between the two systems was statistically significant in all evaluated distances from the apex (P<0.001). During this study fracture of one file (25/0.08) in the Neoniti group occurred. CONCLUSION: Neoniti and Reciproc systems have significant difference in terms of creating canal transportation. Reciproc created more canal transportation in buccolingual and mesiodistal dimensions. |
format | Online Article Text |
id | pubmed-4841342 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Iranian Center for Endodontic Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-48413422016-05-02 Cone-Beam Computed Tomography Assessment of Root Canal Transportation by Neoniti and Reciproc Single-File Systems Moazzami, Fariborz Khojastepour, Leila Nabavizadeh, Mohammadreza Seied Habashi, Mina Iran Endod J Original Article INTRODUCTION: The aim of this in vitro study was to compare the canal transportation of two single-file engine-driven systems, Neoniti and Reciproc, using cone-beam computed tomography (CBCT). METHODS AND MATERIALS: Forty-five non-calcified roots with mature apices and apical curvature of 15-30 degrees were selected from extracted human maxillary molars for this study. Samples were randomly divided into two groups (n=20) and a control group (n=5) and canal preparation with either system was performed according to manufacturers' instructions. Pre- and post-instrumentation CBCT images were captured and the amount of canal transportation within the files was calculated at levels of 3, 4, and 5 mm from the apex. The independent sample t-test was used to analyze the statistical significance between the two groups. The level of significance was defined at 0.05. RESULTS: Reciproc created more canal transportation compared to Neoniti in both mesiodistal and buccolingual directions. The difference between the two systems was statistically significant in all evaluated distances from the apex (P<0.001). During this study fracture of one file (25/0.08) in the Neoniti group occurred. CONCLUSION: Neoniti and Reciproc systems have significant difference in terms of creating canal transportation. Reciproc created more canal transportation in buccolingual and mesiodistal dimensions. Iranian Center for Endodontic Research 2016 2016-03-20 /pmc/articles/PMC4841342/ /pubmed/27141215 http://dx.doi.org/10.7508/iej.2016.02.004 Text en © 2016, Iranian Center for Endodontic Research This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Moazzami, Fariborz Khojastepour, Leila Nabavizadeh, Mohammadreza Seied Habashi, Mina Cone-Beam Computed Tomography Assessment of Root Canal Transportation by Neoniti and Reciproc Single-File Systems |
title | Cone-Beam Computed Tomography Assessment of Root Canal Transportation by Neoniti and Reciproc Single-File Systems |
title_full | Cone-Beam Computed Tomography Assessment of Root Canal Transportation by Neoniti and Reciproc Single-File Systems |
title_fullStr | Cone-Beam Computed Tomography Assessment of Root Canal Transportation by Neoniti and Reciproc Single-File Systems |
title_full_unstemmed | Cone-Beam Computed Tomography Assessment of Root Canal Transportation by Neoniti and Reciproc Single-File Systems |
title_short | Cone-Beam Computed Tomography Assessment of Root Canal Transportation by Neoniti and Reciproc Single-File Systems |
title_sort | cone-beam computed tomography assessment of root canal transportation by neoniti and reciproc single-file systems |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4841342/ https://www.ncbi.nlm.nih.gov/pubmed/27141215 http://dx.doi.org/10.7508/iej.2016.02.004 |
work_keys_str_mv | AT moazzamifariborz conebeamcomputedtomographyassessmentofrootcanaltransportationbyneonitiandreciprocsinglefilesystems AT khojastepourleila conebeamcomputedtomographyassessmentofrootcanaltransportationbyneonitiandreciprocsinglefilesystems AT nabavizadehmohammadreza conebeamcomputedtomographyassessmentofrootcanaltransportationbyneonitiandreciprocsinglefilesystems AT seiedhabashimina conebeamcomputedtomographyassessmentofrootcanaltransportationbyneonitiandreciprocsinglefilesystems |