Cargando…

Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction

BACKGROUND: Chronic otitis media (COM) can be treated with tympanoplasty with or without mastoidectomy. In patients who have undergone middle ear surgery, three-dimensional spiral computed tomography (CT) scan plays an important role in optimizing surgical planning. OBJECTIVES: This study was perfor...

Descripción completa

Detalles Bibliográficos
Autores principales: Naghibi, Saeed, Seifirad, Sirous, Adami Dehkordi, Mahboobeh, Einolghozati, Sasan, Ghaffarian Eidgahi Moghadam, Nafiseh, Akhavan Rezayat, Amir, Seifirad, Soroush
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kowsar 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4841863/
https://www.ncbi.nlm.nih.gov/pubmed/27127583
http://dx.doi.org/10.5812/iranjradiol.9018
_version_ 1782428438304391168
author Naghibi, Saeed
Seifirad, Sirous
Adami Dehkordi, Mahboobeh
Einolghozati, Sasan
Ghaffarian Eidgahi Moghadam, Nafiseh
Akhavan Rezayat, Amir
Seifirad, Soroush
author_facet Naghibi, Saeed
Seifirad, Sirous
Adami Dehkordi, Mahboobeh
Einolghozati, Sasan
Ghaffarian Eidgahi Moghadam, Nafiseh
Akhavan Rezayat, Amir
Seifirad, Soroush
author_sort Naghibi, Saeed
collection PubMed
description BACKGROUND: Chronic otitis media (COM) can be treated with tympanoplasty with or without mastoidectomy. In patients who have undergone middle ear surgery, three-dimensional spiral computed tomography (CT) scan plays an important role in optimizing surgical planning. OBJECTIVES: This study was performed to compare the findings of three-dimensional reconstructed spiral and conventional CT scan of ossicular chain study in patients with COM. PATIENTS AND METHODS: Fifty patients enrolled in the study underwent plane and three dimensional CT scan (PHILIPS-MX 8000). Ossicles changes, mastoid cavity, tympanic cavity, and presence of cholesteatoma were evaluated. Results of the two methods were then compared and interpreted by a radiologist, recorded in questionnaires, and analyzed. Logistic regression test and Kappa coefficient of agreement were used for statistical analyses. RESULTS: Sixty two ears with COM were found in physical examination. A significant difference was observed between the findings of the two methods in ossicle erosion (11.3% in conventional CT vs. 37.1% in spiral CT, P = 0.0001), decrease of mastoid air cells (82.3% in conventional CT vs. 93.5% in spiral CT, P = 0.001), and tympanic cavity opacity (12.9% in conventional CT vs. 40.3% in spiral CT, P=0.0001). No significant difference was observed between the findings of the two methods in ossicle destruction (6.5% conventional CT vs. 56.4% in spiral CT, P = 0.125), and presence of cholesteatoma (3.2% in conventional CT vs. 42% in spiral CT, P = 0.172). In this study, spiral CT scan demonstrated ossicle dislocation in 9.6%, decrease of mastoid air cells in 4.8%, and decrease of volume in the tympanic cavity in 1.6%; whereas, none of these findings were reported in the patients' conventional CT scans. CONCLUSION: Spiral-CT scan is superior to conventional CT in the diagnosis of lesions in COM before operation. It can be used for detailed evaluation of ossicular chain in such patients.
format Online
Article
Text
id pubmed-4841863
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Kowsar
record_format MEDLINE/PubMed
spelling pubmed-48418632016-04-28 Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction Naghibi, Saeed Seifirad, Sirous Adami Dehkordi, Mahboobeh Einolghozati, Sasan Ghaffarian Eidgahi Moghadam, Nafiseh Akhavan Rezayat, Amir Seifirad, Soroush Iran J Radiol Head & Neck Imaging BACKGROUND: Chronic otitis media (COM) can be treated with tympanoplasty with or without mastoidectomy. In patients who have undergone middle ear surgery, three-dimensional spiral computed tomography (CT) scan plays an important role in optimizing surgical planning. OBJECTIVES: This study was performed to compare the findings of three-dimensional reconstructed spiral and conventional CT scan of ossicular chain study in patients with COM. PATIENTS AND METHODS: Fifty patients enrolled in the study underwent plane and three dimensional CT scan (PHILIPS-MX 8000). Ossicles changes, mastoid cavity, tympanic cavity, and presence of cholesteatoma were evaluated. Results of the two methods were then compared and interpreted by a radiologist, recorded in questionnaires, and analyzed. Logistic regression test and Kappa coefficient of agreement were used for statistical analyses. RESULTS: Sixty two ears with COM were found in physical examination. A significant difference was observed between the findings of the two methods in ossicle erosion (11.3% in conventional CT vs. 37.1% in spiral CT, P = 0.0001), decrease of mastoid air cells (82.3% in conventional CT vs. 93.5% in spiral CT, P = 0.001), and tympanic cavity opacity (12.9% in conventional CT vs. 40.3% in spiral CT, P=0.0001). No significant difference was observed between the findings of the two methods in ossicle destruction (6.5% conventional CT vs. 56.4% in spiral CT, P = 0.125), and presence of cholesteatoma (3.2% in conventional CT vs. 42% in spiral CT, P = 0.172). In this study, spiral CT scan demonstrated ossicle dislocation in 9.6%, decrease of mastoid air cells in 4.8%, and decrease of volume in the tympanic cavity in 1.6%; whereas, none of these findings were reported in the patients' conventional CT scans. CONCLUSION: Spiral-CT scan is superior to conventional CT in the diagnosis of lesions in COM before operation. It can be used for detailed evaluation of ossicular chain in such patients. Kowsar 2016-01-26 /pmc/articles/PMC4841863/ /pubmed/27127583 http://dx.doi.org/10.5812/iranjradiol.9018 Text en Copyright © 2016, Tehran University of Medical Sciences and Iranian Society of Radiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited.
spellingShingle Head & Neck Imaging
Naghibi, Saeed
Seifirad, Sirous
Adami Dehkordi, Mahboobeh
Einolghozati, Sasan
Ghaffarian Eidgahi Moghadam, Nafiseh
Akhavan Rezayat, Amir
Seifirad, Soroush
Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction
title Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction
title_full Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction
title_fullStr Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction
title_full_unstemmed Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction
title_short Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction
title_sort comparison of conventional versus spiral computed tomography with three dimensional reconstruction in chronic otitis media with ossicular chain destruction
topic Head & Neck Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4841863/
https://www.ncbi.nlm.nih.gov/pubmed/27127583
http://dx.doi.org/10.5812/iranjradiol.9018
work_keys_str_mv AT naghibisaeed comparisonofconventionalversusspiralcomputedtomographywiththreedimensionalreconstructioninchronicotitismediawithossicularchaindestruction
AT seifiradsirous comparisonofconventionalversusspiralcomputedtomographywiththreedimensionalreconstructioninchronicotitismediawithossicularchaindestruction
AT adamidehkordimahboobeh comparisonofconventionalversusspiralcomputedtomographywiththreedimensionalreconstructioninchronicotitismediawithossicularchaindestruction
AT einolghozatisasan comparisonofconventionalversusspiralcomputedtomographywiththreedimensionalreconstructioninchronicotitismediawithossicularchaindestruction
AT ghaffarianeidgahimoghadamnafiseh comparisonofconventionalversusspiralcomputedtomographywiththreedimensionalreconstructioninchronicotitismediawithossicularchaindestruction
AT akhavanrezayatamir comparisonofconventionalversusspiralcomputedtomographywiththreedimensionalreconstructioninchronicotitismediawithossicularchaindestruction
AT seifiradsoroush comparisonofconventionalversusspiralcomputedtomographywiththreedimensionalreconstructioninchronicotitismediawithossicularchaindestruction