Cargando…
Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction
BACKGROUND: Chronic otitis media (COM) can be treated with tympanoplasty with or without mastoidectomy. In patients who have undergone middle ear surgery, three-dimensional spiral computed tomography (CT) scan plays an important role in optimizing surgical planning. OBJECTIVES: This study was perfor...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kowsar
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4841863/ https://www.ncbi.nlm.nih.gov/pubmed/27127583 http://dx.doi.org/10.5812/iranjradiol.9018 |
_version_ | 1782428438304391168 |
---|---|
author | Naghibi, Saeed Seifirad, Sirous Adami Dehkordi, Mahboobeh Einolghozati, Sasan Ghaffarian Eidgahi Moghadam, Nafiseh Akhavan Rezayat, Amir Seifirad, Soroush |
author_facet | Naghibi, Saeed Seifirad, Sirous Adami Dehkordi, Mahboobeh Einolghozati, Sasan Ghaffarian Eidgahi Moghadam, Nafiseh Akhavan Rezayat, Amir Seifirad, Soroush |
author_sort | Naghibi, Saeed |
collection | PubMed |
description | BACKGROUND: Chronic otitis media (COM) can be treated with tympanoplasty with or without mastoidectomy. In patients who have undergone middle ear surgery, three-dimensional spiral computed tomography (CT) scan plays an important role in optimizing surgical planning. OBJECTIVES: This study was performed to compare the findings of three-dimensional reconstructed spiral and conventional CT scan of ossicular chain study in patients with COM. PATIENTS AND METHODS: Fifty patients enrolled in the study underwent plane and three dimensional CT scan (PHILIPS-MX 8000). Ossicles changes, mastoid cavity, tympanic cavity, and presence of cholesteatoma were evaluated. Results of the two methods were then compared and interpreted by a radiologist, recorded in questionnaires, and analyzed. Logistic regression test and Kappa coefficient of agreement were used for statistical analyses. RESULTS: Sixty two ears with COM were found in physical examination. A significant difference was observed between the findings of the two methods in ossicle erosion (11.3% in conventional CT vs. 37.1% in spiral CT, P = 0.0001), decrease of mastoid air cells (82.3% in conventional CT vs. 93.5% in spiral CT, P = 0.001), and tympanic cavity opacity (12.9% in conventional CT vs. 40.3% in spiral CT, P=0.0001). No significant difference was observed between the findings of the two methods in ossicle destruction (6.5% conventional CT vs. 56.4% in spiral CT, P = 0.125), and presence of cholesteatoma (3.2% in conventional CT vs. 42% in spiral CT, P = 0.172). In this study, spiral CT scan demonstrated ossicle dislocation in 9.6%, decrease of mastoid air cells in 4.8%, and decrease of volume in the tympanic cavity in 1.6%; whereas, none of these findings were reported in the patients' conventional CT scans. CONCLUSION: Spiral-CT scan is superior to conventional CT in the diagnosis of lesions in COM before operation. It can be used for detailed evaluation of ossicular chain in such patients. |
format | Online Article Text |
id | pubmed-4841863 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Kowsar |
record_format | MEDLINE/PubMed |
spelling | pubmed-48418632016-04-28 Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction Naghibi, Saeed Seifirad, Sirous Adami Dehkordi, Mahboobeh Einolghozati, Sasan Ghaffarian Eidgahi Moghadam, Nafiseh Akhavan Rezayat, Amir Seifirad, Soroush Iran J Radiol Head & Neck Imaging BACKGROUND: Chronic otitis media (COM) can be treated with tympanoplasty with or without mastoidectomy. In patients who have undergone middle ear surgery, three-dimensional spiral computed tomography (CT) scan plays an important role in optimizing surgical planning. OBJECTIVES: This study was performed to compare the findings of three-dimensional reconstructed spiral and conventional CT scan of ossicular chain study in patients with COM. PATIENTS AND METHODS: Fifty patients enrolled in the study underwent plane and three dimensional CT scan (PHILIPS-MX 8000). Ossicles changes, mastoid cavity, tympanic cavity, and presence of cholesteatoma were evaluated. Results of the two methods were then compared and interpreted by a radiologist, recorded in questionnaires, and analyzed. Logistic regression test and Kappa coefficient of agreement were used for statistical analyses. RESULTS: Sixty two ears with COM were found in physical examination. A significant difference was observed between the findings of the two methods in ossicle erosion (11.3% in conventional CT vs. 37.1% in spiral CT, P = 0.0001), decrease of mastoid air cells (82.3% in conventional CT vs. 93.5% in spiral CT, P = 0.001), and tympanic cavity opacity (12.9% in conventional CT vs. 40.3% in spiral CT, P=0.0001). No significant difference was observed between the findings of the two methods in ossicle destruction (6.5% conventional CT vs. 56.4% in spiral CT, P = 0.125), and presence of cholesteatoma (3.2% in conventional CT vs. 42% in spiral CT, P = 0.172). In this study, spiral CT scan demonstrated ossicle dislocation in 9.6%, decrease of mastoid air cells in 4.8%, and decrease of volume in the tympanic cavity in 1.6%; whereas, none of these findings were reported in the patients' conventional CT scans. CONCLUSION: Spiral-CT scan is superior to conventional CT in the diagnosis of lesions in COM before operation. It can be used for detailed evaluation of ossicular chain in such patients. Kowsar 2016-01-26 /pmc/articles/PMC4841863/ /pubmed/27127583 http://dx.doi.org/10.5812/iranjradiol.9018 Text en Copyright © 2016, Tehran University of Medical Sciences and Iranian Society of Radiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited. |
spellingShingle | Head & Neck Imaging Naghibi, Saeed Seifirad, Sirous Adami Dehkordi, Mahboobeh Einolghozati, Sasan Ghaffarian Eidgahi Moghadam, Nafiseh Akhavan Rezayat, Amir Seifirad, Soroush Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction |
title | Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction |
title_full | Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction |
title_fullStr | Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction |
title_full_unstemmed | Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction |
title_short | Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction |
title_sort | comparison of conventional versus spiral computed tomography with three dimensional reconstruction in chronic otitis media with ossicular chain destruction |
topic | Head & Neck Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4841863/ https://www.ncbi.nlm.nih.gov/pubmed/27127583 http://dx.doi.org/10.5812/iranjradiol.9018 |
work_keys_str_mv | AT naghibisaeed comparisonofconventionalversusspiralcomputedtomographywiththreedimensionalreconstructioninchronicotitismediawithossicularchaindestruction AT seifiradsirous comparisonofconventionalversusspiralcomputedtomographywiththreedimensionalreconstructioninchronicotitismediawithossicularchaindestruction AT adamidehkordimahboobeh comparisonofconventionalversusspiralcomputedtomographywiththreedimensionalreconstructioninchronicotitismediawithossicularchaindestruction AT einolghozatisasan comparisonofconventionalversusspiralcomputedtomographywiththreedimensionalreconstructioninchronicotitismediawithossicularchaindestruction AT ghaffarianeidgahimoghadamnafiseh comparisonofconventionalversusspiralcomputedtomographywiththreedimensionalreconstructioninchronicotitismediawithossicularchaindestruction AT akhavanrezayatamir comparisonofconventionalversusspiralcomputedtomographywiththreedimensionalreconstructioninchronicotitismediawithossicularchaindestruction AT seifiradsoroush comparisonofconventionalversusspiralcomputedtomographywiththreedimensionalreconstructioninchronicotitismediawithossicularchaindestruction |