Cargando…

Masking Agents Evaluation for Lead Determination by Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry Technique: Effect of KI, L-Cysteine, and 1,10-Phenanthroline

Hydride generation (HG) of lead technique presents interferences from foreign ions of complex matrix samples. In order to minimize these interferences, the effect of masking agents such as KI, L-cysteine, and 1,10-phenanthroline was studied in the absence and in the presence of selected interfering...

Descripción completa

Detalles Bibliográficos
Autores principales: Beltrán, Blanca G., Leal, Luz O., Ferrer, Laura, Cerdà, Víctor
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4842378/
https://www.ncbi.nlm.nih.gov/pubmed/27148365
http://dx.doi.org/10.1155/2016/3095120
_version_ 1782428507225194496
author Beltrán, Blanca G.
Leal, Luz O.
Ferrer, Laura
Cerdà, Víctor
author_facet Beltrán, Blanca G.
Leal, Luz O.
Ferrer, Laura
Cerdà, Víctor
author_sort Beltrán, Blanca G.
collection PubMed
description Hydride generation (HG) of lead technique presents interferences from foreign ions of complex matrix samples. In order to minimize these interferences, the effect of masking agents such as KI, L-cysteine, and 1,10-phenanthroline was studied in the absence and in the presence of selected interfering species (As, Cr, Cu, and Fe). Different modes of addition of masking agents were accomplished, that is, to either sample or KBH(4) reducing solution. The lead determinations were performed using a flow injection analysis (FIA) system coupled to HG and atomic fluorescence spectrometry (AFS). The linearity of calibration curves (1–10 μg Pb L(−1)) was not affected by the addition of the masking agents. The use of KI in the reducing solution diminished interferences from concentrations of As and Cu, while 1,10-phenanthroline showed a positive effect on the interference by As. Moreover, Cr and Cu appeared to be the most serious interfering ions for plumbane (PbH(4)), because they drastically reduced the analytical signal of lead. Fe did not present any interference under the employed experimental conditions, even at high levels. The accuracy was established through the analysis of certified reference material (i.e., BCR-610, groundwater) using KI as masking agent. The detection limit reached by FIA-HG-AFS proposed methodology was 0.03 μg Pb L(−1).
format Online
Article
Text
id pubmed-4842378
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-48423782016-05-04 Masking Agents Evaluation for Lead Determination by Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry Technique: Effect of KI, L-Cysteine, and 1,10-Phenanthroline Beltrán, Blanca G. Leal, Luz O. Ferrer, Laura Cerdà, Víctor Int J Anal Chem Research Article Hydride generation (HG) of lead technique presents interferences from foreign ions of complex matrix samples. In order to minimize these interferences, the effect of masking agents such as KI, L-cysteine, and 1,10-phenanthroline was studied in the absence and in the presence of selected interfering species (As, Cr, Cu, and Fe). Different modes of addition of masking agents were accomplished, that is, to either sample or KBH(4) reducing solution. The lead determinations were performed using a flow injection analysis (FIA) system coupled to HG and atomic fluorescence spectrometry (AFS). The linearity of calibration curves (1–10 μg Pb L(−1)) was not affected by the addition of the masking agents. The use of KI in the reducing solution diminished interferences from concentrations of As and Cu, while 1,10-phenanthroline showed a positive effect on the interference by As. Moreover, Cr and Cu appeared to be the most serious interfering ions for plumbane (PbH(4)), because they drastically reduced the analytical signal of lead. Fe did not present any interference under the employed experimental conditions, even at high levels. The accuracy was established through the analysis of certified reference material (i.e., BCR-610, groundwater) using KI as masking agent. The detection limit reached by FIA-HG-AFS proposed methodology was 0.03 μg Pb L(−1). Hindawi Publishing Corporation 2016 2016-04-11 /pmc/articles/PMC4842378/ /pubmed/27148365 http://dx.doi.org/10.1155/2016/3095120 Text en Copyright © 2016 Blanca G. Beltrán et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Beltrán, Blanca G.
Leal, Luz O.
Ferrer, Laura
Cerdà, Víctor
Masking Agents Evaluation for Lead Determination by Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry Technique: Effect of KI, L-Cysteine, and 1,10-Phenanthroline
title Masking Agents Evaluation for Lead Determination by Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry Technique: Effect of KI, L-Cysteine, and 1,10-Phenanthroline
title_full Masking Agents Evaluation for Lead Determination by Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry Technique: Effect of KI, L-Cysteine, and 1,10-Phenanthroline
title_fullStr Masking Agents Evaluation for Lead Determination by Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry Technique: Effect of KI, L-Cysteine, and 1,10-Phenanthroline
title_full_unstemmed Masking Agents Evaluation for Lead Determination by Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry Technique: Effect of KI, L-Cysteine, and 1,10-Phenanthroline
title_short Masking Agents Evaluation for Lead Determination by Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry Technique: Effect of KI, L-Cysteine, and 1,10-Phenanthroline
title_sort masking agents evaluation for lead determination by flow injection-hydride generation-atomic fluorescence spectrometry technique: effect of ki, l-cysteine, and 1,10-phenanthroline
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4842378/
https://www.ncbi.nlm.nih.gov/pubmed/27148365
http://dx.doi.org/10.1155/2016/3095120
work_keys_str_mv AT beltranblancag maskingagentsevaluationforleaddeterminationbyflowinjectionhydridegenerationatomicfluorescencespectrometrytechniqueeffectofkilcysteineand110phenanthroline
AT lealluzo maskingagentsevaluationforleaddeterminationbyflowinjectionhydridegenerationatomicfluorescencespectrometrytechniqueeffectofkilcysteineand110phenanthroline
AT ferrerlaura maskingagentsevaluationforleaddeterminationbyflowinjectionhydridegenerationatomicfluorescencespectrometrytechniqueeffectofkilcysteineand110phenanthroline
AT cerdavictor maskingagentsevaluationforleaddeterminationbyflowinjectionhydridegenerationatomicfluorescencespectrometrytechniqueeffectofkilcysteineand110phenanthroline