Long-Term Effects of Segmental Lumbar Spinal Fusion on Adjacent Healthy Discs: A Finite Element Study

STUDY DESIGN: Experimental study. PURPOSE: The aim of the study was to develop a finite element (FE) model to study the long-term effects of various types of lumbar spinal interventions on the discs adjacent to the fused segment. OVERVIEW OF LITERATURE: Earlier FE studies have been limited to one pa...

Descripción completa

Detalles Bibliográficos
Autores principales: Srinivas, Gunti Ranga, Deb, Anindya, Kumar, Malhar N., Kurnool, Goutham
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Spine Surgery 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4843054/
https://www.ncbi.nlm.nih.gov/pubmed/27114758
http://dx.doi.org/10.4184/asj.2016.10.2.205
Descripción
Sumario:STUDY DESIGN: Experimental study. PURPOSE: The aim of the study was to develop a finite element (FE) model to study the long-term effects of various types of lumbar spinal interventions on the discs adjacent to the fused segment. OVERVIEW OF LITERATURE: Earlier FE studies have been limited to one particular type of fusion and comparative quantification of the adjacent disc stresses for different types of surgical interventions has not been reported. METHODS: A computer aided engineering (CAE) based approach using implicit FE analysis assessed the stresses in the lumbar discs adjacent to the fused segment following anterior and posterior lumbar spine fusions at one, two and three levels (with and without instrumentation). RESULTS: It was found that instrumentation and length of fusion were the most significant factors in increasing adjacent level stresses in the lumbar discs. CONCLUSIONS: In the present study, a calibrated FE model that examined spinal interventions under similar loading and boundary conditions was used to provide quantitative data which would be useful for clinicians to understand the probable long-term effect of their choice of surgical intervention.