Cargando…
Force Outputs during Squats Performed Using a Rotational Inertia Device under Stable versus Unstable Conditions with Different Loads
The purpose of the study was to compare the force outputs achieved during a squat exercise using a rotational inertia device in stable versus unstable conditions with different loads and in concentric and eccentric phases. Thirteen male athletes (mean ± SD: age 23.7 ± 3.0 years, height 1.80 ± 0.08 m...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4844129/ https://www.ncbi.nlm.nih.gov/pubmed/27111766 http://dx.doi.org/10.1371/journal.pone.0154346 |
_version_ | 1782428721477582848 |
---|---|
author | Vázquez-Guerrero, Jairo Moras, Gerard Baeza, Jennifer Rodríguez-Jiménez, Sergio |
author_facet | Vázquez-Guerrero, Jairo Moras, Gerard Baeza, Jennifer Rodríguez-Jiménez, Sergio |
author_sort | Vázquez-Guerrero, Jairo |
collection | PubMed |
description | The purpose of the study was to compare the force outputs achieved during a squat exercise using a rotational inertia device in stable versus unstable conditions with different loads and in concentric and eccentric phases. Thirteen male athletes (mean ± SD: age 23.7 ± 3.0 years, height 1.80 ± 0.08 m, body mass 77.4 ± 7.9 kg) were assessed while squatting, performing one set of three repetitions with four different loads under stable and unstable conditions at maximum concentric effort. Overall, there were no significant differences between the stable and unstable conditions at each of the loads for any of the dependent variables. Mean force showed significant differences between some of the loads in stable and unstable conditions (P < 0.010) and peak force output differed between all loads for each condition (P < 0.045). Mean force outputs were greater in the concentric than in the eccentric phase under both conditions and with all loads (P < 0.001). There were no significant differences in peak force between concentric and eccentric phases at any load in either stable or unstable conditions. In conclusion, squatting with a rotational inertia device allowed the generation of similar force outputs under stable and unstable conditions at each of the four loads. The study also provides empirical evidence of the different force outputs achieved by adjusting load conditions on the rotational inertia device when performing squats, especially in the case of peak force. Concentric force outputs were significantly higher than eccentric outputs, except for peak force under both conditions. These findings support the use of the rotational inertia device to train the squatting exercise under unstable conditions for strength and conditioning trainers. The device could also be included in injury prevention programs for muscle lesions and ankle and knee joint injuries. |
format | Online Article Text |
id | pubmed-4844129 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-48441292016-05-05 Force Outputs during Squats Performed Using a Rotational Inertia Device under Stable versus Unstable Conditions with Different Loads Vázquez-Guerrero, Jairo Moras, Gerard Baeza, Jennifer Rodríguez-Jiménez, Sergio PLoS One Research Article The purpose of the study was to compare the force outputs achieved during a squat exercise using a rotational inertia device in stable versus unstable conditions with different loads and in concentric and eccentric phases. Thirteen male athletes (mean ± SD: age 23.7 ± 3.0 years, height 1.80 ± 0.08 m, body mass 77.4 ± 7.9 kg) were assessed while squatting, performing one set of three repetitions with four different loads under stable and unstable conditions at maximum concentric effort. Overall, there were no significant differences between the stable and unstable conditions at each of the loads for any of the dependent variables. Mean force showed significant differences between some of the loads in stable and unstable conditions (P < 0.010) and peak force output differed between all loads for each condition (P < 0.045). Mean force outputs were greater in the concentric than in the eccentric phase under both conditions and with all loads (P < 0.001). There were no significant differences in peak force between concentric and eccentric phases at any load in either stable or unstable conditions. In conclusion, squatting with a rotational inertia device allowed the generation of similar force outputs under stable and unstable conditions at each of the four loads. The study also provides empirical evidence of the different force outputs achieved by adjusting load conditions on the rotational inertia device when performing squats, especially in the case of peak force. Concentric force outputs were significantly higher than eccentric outputs, except for peak force under both conditions. These findings support the use of the rotational inertia device to train the squatting exercise under unstable conditions for strength and conditioning trainers. The device could also be included in injury prevention programs for muscle lesions and ankle and knee joint injuries. Public Library of Science 2016-04-25 /pmc/articles/PMC4844129/ /pubmed/27111766 http://dx.doi.org/10.1371/journal.pone.0154346 Text en © 2016 Vázquez-Guerrero et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Vázquez-Guerrero, Jairo Moras, Gerard Baeza, Jennifer Rodríguez-Jiménez, Sergio Force Outputs during Squats Performed Using a Rotational Inertia Device under Stable versus Unstable Conditions with Different Loads |
title | Force Outputs during Squats Performed Using a Rotational Inertia Device under Stable versus Unstable Conditions with Different Loads |
title_full | Force Outputs during Squats Performed Using a Rotational Inertia Device under Stable versus Unstable Conditions with Different Loads |
title_fullStr | Force Outputs during Squats Performed Using a Rotational Inertia Device under Stable versus Unstable Conditions with Different Loads |
title_full_unstemmed | Force Outputs during Squats Performed Using a Rotational Inertia Device under Stable versus Unstable Conditions with Different Loads |
title_short | Force Outputs during Squats Performed Using a Rotational Inertia Device under Stable versus Unstable Conditions with Different Loads |
title_sort | force outputs during squats performed using a rotational inertia device under stable versus unstable conditions with different loads |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4844129/ https://www.ncbi.nlm.nih.gov/pubmed/27111766 http://dx.doi.org/10.1371/journal.pone.0154346 |
work_keys_str_mv | AT vazquezguerrerojairo forceoutputsduringsquatsperformedusingarotationalinertiadeviceunderstableversusunstableconditionswithdifferentloads AT morasgerard forceoutputsduringsquatsperformedusingarotationalinertiadeviceunderstableversusunstableconditionswithdifferentloads AT baezajennifer forceoutputsduringsquatsperformedusingarotationalinertiadeviceunderstableversusunstableconditionswithdifferentloads AT rodriguezjimenezsergio forceoutputsduringsquatsperformedusingarotationalinertiadeviceunderstableversusunstableconditionswithdifferentloads |