A Primary Dead-Weight Tester for Pressures (0.05–1.0) MPa
Recent advances in technology on two fronts, 1) the fabrication of large-diameter pistons and cylinders with good geometry, and 2) the ability to measure the dimensions of these components with high accuracy, have allowed dead-weight testers at the National Institute of Standards and Technology (NIS...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
2003
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4844511/ https://www.ncbi.nlm.nih.gov/pubmed/27413600 http://dx.doi.org/10.6028/jres.108.013 |
_version_ | 1782428786861539328 |
---|---|
author | Jain, Kamlesh Bowers, Walt Schmidt, James W. |
author_facet | Jain, Kamlesh Bowers, Walt Schmidt, James W. |
author_sort | Jain, Kamlesh |
collection | PubMed |
description | Recent advances in technology on two fronts, 1) the fabrication of large-diameter pistons and cylinders with good geometry, and 2) the ability to measure the dimensions of these components with high accuracy, have allowed dead-weight testers at the National Institute of Standards and Technology (NIST) to generate pressures that approach total relative uncertainties previously obtained only by manometers. This paper describes a 35 mm diameter piston/cylinder assembly (known within NIST as PG-39) that serves as a pressure standard in which both the piston and the cylinder have been accurately dimensioned by Physikalisch Technische Bundesanstalt (PTB). Both artifacts (piston and cylinder) appeared to be round within ±30 nm and straight within ±100 nm over a substantial fraction of their heights. Based on the diameters at 20 °C provided by PTB (±15 nm) and on the good geometry of the artifact, the relative uncertainties for the effective area were estimated to be about 2.2 × 10(−6) (1σ). |
format | Online Article Text |
id | pubmed-4844511 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2003 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-48445112016-07-13 A Primary Dead-Weight Tester for Pressures (0.05–1.0) MPa Jain, Kamlesh Bowers, Walt Schmidt, James W. J Res Natl Inst Stand Technol Article Recent advances in technology on two fronts, 1) the fabrication of large-diameter pistons and cylinders with good geometry, and 2) the ability to measure the dimensions of these components with high accuracy, have allowed dead-weight testers at the National Institute of Standards and Technology (NIST) to generate pressures that approach total relative uncertainties previously obtained only by manometers. This paper describes a 35 mm diameter piston/cylinder assembly (known within NIST as PG-39) that serves as a pressure standard in which both the piston and the cylinder have been accurately dimensioned by Physikalisch Technische Bundesanstalt (PTB). Both artifacts (piston and cylinder) appeared to be round within ±30 nm and straight within ±100 nm over a substantial fraction of their heights. Based on the diameters at 20 °C provided by PTB (±15 nm) and on the good geometry of the artifact, the relative uncertainties for the effective area were estimated to be about 2.2 × 10(−6) (1σ). [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2003 2003-04-01 /pmc/articles/PMC4844511/ /pubmed/27413600 http://dx.doi.org/10.6028/jres.108.013 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Jain, Kamlesh Bowers, Walt Schmidt, James W. A Primary Dead-Weight Tester for Pressures (0.05–1.0) MPa |
title | A Primary Dead-Weight Tester for Pressures (0.05–1.0) MPa |
title_full | A Primary Dead-Weight Tester for Pressures (0.05–1.0) MPa |
title_fullStr | A Primary Dead-Weight Tester for Pressures (0.05–1.0) MPa |
title_full_unstemmed | A Primary Dead-Weight Tester for Pressures (0.05–1.0) MPa |
title_short | A Primary Dead-Weight Tester for Pressures (0.05–1.0) MPa |
title_sort | primary dead-weight tester for pressures (0.05–1.0) mpa |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4844511/ https://www.ncbi.nlm.nih.gov/pubmed/27413600 http://dx.doi.org/10.6028/jres.108.013 |
work_keys_str_mv | AT jainkamlesh aprimarydeadweighttesterforpressures00510mpa AT bowerswalt aprimarydeadweighttesterforpressures00510mpa AT schmidtjamesw aprimarydeadweighttesterforpressures00510mpa AT jainkamlesh primarydeadweighttesterforpressures00510mpa AT bowerswalt primarydeadweighttesterforpressures00510mpa AT schmidtjamesw primarydeadweighttesterforpressures00510mpa |