Cargando…

Cuspal Displacement Induced by Bulk Fill Resin Composite Polymerization: Biomechanical Evaluation Using Fiber Bragg Grating Sensors

Polymerization shrinkage is a major concern to the clinical success of direct composite resin restorations. The aim of this study was to compare the effect of polymerization shrinkage strain of two resin composites on cuspal movement based on the use of fiber Bragg grating (FBG) sensors. Twenty stan...

Descripción completa

Detalles Bibliográficos
Autores principales: Vinagre, Alexandra, Ramos, João, Alves, Sofia, Messias, Ana, Alberto, Nélia, Nogueira, Rogério
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4844892/
https://www.ncbi.nlm.nih.gov/pubmed/27190517
http://dx.doi.org/10.1155/2016/7134283
_version_ 1782428836080648192
author Vinagre, Alexandra
Ramos, João
Alves, Sofia
Messias, Ana
Alberto, Nélia
Nogueira, Rogério
author_facet Vinagre, Alexandra
Ramos, João
Alves, Sofia
Messias, Ana
Alberto, Nélia
Nogueira, Rogério
author_sort Vinagre, Alexandra
collection PubMed
description Polymerization shrinkage is a major concern to the clinical success of direct composite resin restorations. The aim of this study was to compare the effect of polymerization shrinkage strain of two resin composites on cuspal movement based on the use of fiber Bragg grating (FBG) sensors. Twenty standardized Class II cavities prepared in upper third molars were allocated into two groups (n = 10). Restorations involved the bulk fill placement of conventional microhybrid resin composite (Esthet•X® HD, Dentsply DeTrey) (Group 1) or flowable “low-shrinkage” resin composite (SDR™, Dentsply DeTrey) (Group 2). Two FBG sensors were used per restoration for real-time measurement of cuspal linear deformation and temperature variation. Group comparisons were determined using ANCOVA (α = 0.05) considering temperature as the covariate. A statistically significant correlation between cuspal deflection, time, and material was observed (p < 0.01). Cuspal deflection reached 8.8 μm (0.23%) and 7.8 μm (0.20%) in Groups 1 and 2, respectively. When used with bulk fill technique, flowable resin composite SDR™ induced significantly less cuspal deflection than the conventional resin composite Esthet•X® HD (p = 0.015) and presented a smoother curve slope during the polymerization. FBG sensors appear to be a valid tool for accurate real-time monitoring of cuspal deformation.
format Online
Article
Text
id pubmed-4844892
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-48448922016-05-17 Cuspal Displacement Induced by Bulk Fill Resin Composite Polymerization: Biomechanical Evaluation Using Fiber Bragg Grating Sensors Vinagre, Alexandra Ramos, João Alves, Sofia Messias, Ana Alberto, Nélia Nogueira, Rogério Int J Biomater Research Article Polymerization shrinkage is a major concern to the clinical success of direct composite resin restorations. The aim of this study was to compare the effect of polymerization shrinkage strain of two resin composites on cuspal movement based on the use of fiber Bragg grating (FBG) sensors. Twenty standardized Class II cavities prepared in upper third molars were allocated into two groups (n = 10). Restorations involved the bulk fill placement of conventional microhybrid resin composite (Esthet•X® HD, Dentsply DeTrey) (Group 1) or flowable “low-shrinkage” resin composite (SDR™, Dentsply DeTrey) (Group 2). Two FBG sensors were used per restoration for real-time measurement of cuspal linear deformation and temperature variation. Group comparisons were determined using ANCOVA (α = 0.05) considering temperature as the covariate. A statistically significant correlation between cuspal deflection, time, and material was observed (p < 0.01). Cuspal deflection reached 8.8 μm (0.23%) and 7.8 μm (0.20%) in Groups 1 and 2, respectively. When used with bulk fill technique, flowable resin composite SDR™ induced significantly less cuspal deflection than the conventional resin composite Esthet•X® HD (p = 0.015) and presented a smoother curve slope during the polymerization. FBG sensors appear to be a valid tool for accurate real-time monitoring of cuspal deformation. Hindawi Publishing Corporation 2016 2016-04-12 /pmc/articles/PMC4844892/ /pubmed/27190517 http://dx.doi.org/10.1155/2016/7134283 Text en Copyright © 2016 Alexandra Vinagre et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Vinagre, Alexandra
Ramos, João
Alves, Sofia
Messias, Ana
Alberto, Nélia
Nogueira, Rogério
Cuspal Displacement Induced by Bulk Fill Resin Composite Polymerization: Biomechanical Evaluation Using Fiber Bragg Grating Sensors
title Cuspal Displacement Induced by Bulk Fill Resin Composite Polymerization: Biomechanical Evaluation Using Fiber Bragg Grating Sensors
title_full Cuspal Displacement Induced by Bulk Fill Resin Composite Polymerization: Biomechanical Evaluation Using Fiber Bragg Grating Sensors
title_fullStr Cuspal Displacement Induced by Bulk Fill Resin Composite Polymerization: Biomechanical Evaluation Using Fiber Bragg Grating Sensors
title_full_unstemmed Cuspal Displacement Induced by Bulk Fill Resin Composite Polymerization: Biomechanical Evaluation Using Fiber Bragg Grating Sensors
title_short Cuspal Displacement Induced by Bulk Fill Resin Composite Polymerization: Biomechanical Evaluation Using Fiber Bragg Grating Sensors
title_sort cuspal displacement induced by bulk fill resin composite polymerization: biomechanical evaluation using fiber bragg grating sensors
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4844892/
https://www.ncbi.nlm.nih.gov/pubmed/27190517
http://dx.doi.org/10.1155/2016/7134283
work_keys_str_mv AT vinagrealexandra cuspaldisplacementinducedbybulkfillresincompositepolymerizationbiomechanicalevaluationusingfiberbragggratingsensors
AT ramosjoao cuspaldisplacementinducedbybulkfillresincompositepolymerizationbiomechanicalevaluationusingfiberbragggratingsensors
AT alvessofia cuspaldisplacementinducedbybulkfillresincompositepolymerizationbiomechanicalevaluationusingfiberbragggratingsensors
AT messiasana cuspaldisplacementinducedbybulkfillresincompositepolymerizationbiomechanicalevaluationusingfiberbragggratingsensors
AT albertonelia cuspaldisplacementinducedbybulkfillresincompositepolymerizationbiomechanicalevaluationusingfiberbragggratingsensors
AT nogueirarogerio cuspaldisplacementinducedbybulkfillresincompositepolymerizationbiomechanicalevaluationusingfiberbragggratingsensors