Cargando…
Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects
OBJECTIVES: This study aimed to compare the diagnostic accuracy of inverted and unprocessed digitized periapical radiographs for detection of peri-implant defects. MATERIALS AND METHODS: A total of 30 osteotomy sites were prepared in three groups of control, study group 1 with 0.425 mm defects and s...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tehran University of Medical Sciences
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4847162/ https://www.ncbi.nlm.nih.gov/pubmed/27123016 |
_version_ | 1782429157021450240 |
---|---|
author | Pourhashemi, Seyed Jalal Ghoncheh, Zahra Kiani, Mohammad Taghi Emami, Raheleh Kharazifard, Mohamad Javad |
author_facet | Pourhashemi, Seyed Jalal Ghoncheh, Zahra Kiani, Mohammad Taghi Emami, Raheleh Kharazifard, Mohamad Javad |
author_sort | Pourhashemi, Seyed Jalal |
collection | PubMed |
description | OBJECTIVES: This study aimed to compare the diagnostic accuracy of inverted and unprocessed digitized periapical radiographs for detection of peri-implant defects. MATERIALS AND METHODS: A total of 30 osteotomy sites were prepared in three groups of control, study group 1 with 0.425 mm defects and study group 2 with 0.725 mm defects using the SIC and Astra Tech drill systems with 4.25mm and 4.85mm diameters. Small and large defects were randomly created in the coronal 8mm of 20 implant sites; implants (3.4mm diameter, 14.5mm length) were then placed. Thirty periapical (PA) radiographs were obtained using Digora imaging system (Soredex Corporation, Helsinki, Finland), size 2 photostimulable storage phosphor (PSP) plate sensors (40.0mm×30.0mm) and Scanora software. Unprocessed images were inverted using Scanora software by applying image inversion and a total of 60 images were obtained and randomly evaluated by four oral and maxillofacial radiologists. Data were analyzed using the t-test. RESULTS: Significant differences were observed in absolute and complete sensitivity and specificity of the two imaging modalities for detection of small and large defects (P<0.05). Unprocessed digital images had a higher mean in terms of absolute sensitivity for detection of small defects, complete sensitivity for detection of large peri-implant defects and definite rule out of defects compared with inverted images. CONCLUSION: Unprocessed digital images have a higher diagnostic value for detection of small and large peri-implant defects and also for definite rule out of defects compared with inverted images. |
format | Online Article Text |
id | pubmed-4847162 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Tehran University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-48471622016-04-27 Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects Pourhashemi, Seyed Jalal Ghoncheh, Zahra Kiani, Mohammad Taghi Emami, Raheleh Kharazifard, Mohamad Javad J Dent (Tehran) Original Article OBJECTIVES: This study aimed to compare the diagnostic accuracy of inverted and unprocessed digitized periapical radiographs for detection of peri-implant defects. MATERIALS AND METHODS: A total of 30 osteotomy sites were prepared in three groups of control, study group 1 with 0.425 mm defects and study group 2 with 0.725 mm defects using the SIC and Astra Tech drill systems with 4.25mm and 4.85mm diameters. Small and large defects were randomly created in the coronal 8mm of 20 implant sites; implants (3.4mm diameter, 14.5mm length) were then placed. Thirty periapical (PA) radiographs were obtained using Digora imaging system (Soredex Corporation, Helsinki, Finland), size 2 photostimulable storage phosphor (PSP) plate sensors (40.0mm×30.0mm) and Scanora software. Unprocessed images were inverted using Scanora software by applying image inversion and a total of 60 images were obtained and randomly evaluated by four oral and maxillofacial radiologists. Data were analyzed using the t-test. RESULTS: Significant differences were observed in absolute and complete sensitivity and specificity of the two imaging modalities for detection of small and large defects (P<0.05). Unprocessed digital images had a higher mean in terms of absolute sensitivity for detection of small defects, complete sensitivity for detection of large peri-implant defects and definite rule out of defects compared with inverted images. CONCLUSION: Unprocessed digital images have a higher diagnostic value for detection of small and large peri-implant defects and also for definite rule out of defects compared with inverted images. Tehran University of Medical Sciences 2015-08 /pmc/articles/PMC4847162/ /pubmed/27123016 Text en Copyright© Dental Research Center, Tehran University of Medical Sciences This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly. |
spellingShingle | Original Article Pourhashemi, Seyed Jalal Ghoncheh, Zahra Kiani, Mohammad Taghi Emami, Raheleh Kharazifard, Mohamad Javad Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects |
title | Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects |
title_full | Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects |
title_fullStr | Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects |
title_full_unstemmed | Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects |
title_short | Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects |
title_sort | diagnostic accuracy of inverted and unprocessed digitized periapical radiographs for detection of peri-implant defects |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4847162/ https://www.ncbi.nlm.nih.gov/pubmed/27123016 |
work_keys_str_mv | AT pourhashemiseyedjalal diagnosticaccuracyofinvertedandunprocesseddigitizedperiapicalradiographsfordetectionofperiimplantdefects AT ghonchehzahra diagnosticaccuracyofinvertedandunprocesseddigitizedperiapicalradiographsfordetectionofperiimplantdefects AT kianimohammadtaghi diagnosticaccuracyofinvertedandunprocesseddigitizedperiapicalradiographsfordetectionofperiimplantdefects AT emamiraheleh diagnosticaccuracyofinvertedandunprocesseddigitizedperiapicalradiographsfordetectionofperiimplantdefects AT kharazifardmohamadjavad diagnosticaccuracyofinvertedandunprocesseddigitizedperiapicalradiographsfordetectionofperiimplantdefects |