Cargando…

Changes in the U.S. Primary Standards for the Air Kerma From Gamma-Ray Beams

Monte Carlo photon-electron transport calculations have been done to derive new wall corrections for the six NBS-NIST standard graphite-wall, air-ionization cavity chambers that serve as the U.S. national primary standard for air kerma (and exposure) for gamma rays from (60)Co, (137)Cs, and (192)Ir...

Descripción completa

Detalles Bibliográficos
Autores principales: Seltzer, Stephen M., Bergstrom, Paul M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2003
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4847583/
https://www.ncbi.nlm.nih.gov/pubmed/27413615
http://dx.doi.org/10.6028/jres.108.031
_version_ 1782429242311573504
author Seltzer, Stephen M.
Bergstrom, Paul M.
author_facet Seltzer, Stephen M.
Bergstrom, Paul M.
author_sort Seltzer, Stephen M.
collection PubMed
description Monte Carlo photon-electron transport calculations have been done to derive new wall corrections for the six NBS-NIST standard graphite-wall, air-ionization cavity chambers that serve as the U.S. national primary standard for air kerma (and exposure) for gamma rays from (60)Co, (137)Cs, and (192)Ir sources. The data developed for and from these calculations have also been used to refine a number of other factors affecting the standards. The largest changes are due to the new wall corrections, and the total changes are +0.87 % to +1.11 % (depending on the chamber) for (60)Co beams, +0.64 % to +1.07 % (depending on the chamber) for (137)Cs beams, and −0.06 % for the single chamber used in the measurement of the standardized (192)Ir source. The primary standards for air kerma will be adjusted in the near future to reflect the changes in factors described in this work.
format Online
Article
Text
id pubmed-4847583
institution National Center for Biotechnology Information
language English
publishDate 2003
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-48475832016-07-13 Changes in the U.S. Primary Standards for the Air Kerma From Gamma-Ray Beams Seltzer, Stephen M. Bergstrom, Paul M. J Res Natl Inst Stand Technol Article Monte Carlo photon-electron transport calculations have been done to derive new wall corrections for the six NBS-NIST standard graphite-wall, air-ionization cavity chambers that serve as the U.S. national primary standard for air kerma (and exposure) for gamma rays from (60)Co, (137)Cs, and (192)Ir sources. The data developed for and from these calculations have also been used to refine a number of other factors affecting the standards. The largest changes are due to the new wall corrections, and the total changes are +0.87 % to +1.11 % (depending on the chamber) for (60)Co beams, +0.64 % to +1.07 % (depending on the chamber) for (137)Cs beams, and −0.06 % for the single chamber used in the measurement of the standardized (192)Ir source. The primary standards for air kerma will be adjusted in the near future to reflect the changes in factors described in this work. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2003 2003-10-01 /pmc/articles/PMC4847583/ /pubmed/27413615 http://dx.doi.org/10.6028/jres.108.031 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Seltzer, Stephen M.
Bergstrom, Paul M.
Changes in the U.S. Primary Standards for the Air Kerma From Gamma-Ray Beams
title Changes in the U.S. Primary Standards for the Air Kerma From Gamma-Ray Beams
title_full Changes in the U.S. Primary Standards for the Air Kerma From Gamma-Ray Beams
title_fullStr Changes in the U.S. Primary Standards for the Air Kerma From Gamma-Ray Beams
title_full_unstemmed Changes in the U.S. Primary Standards for the Air Kerma From Gamma-Ray Beams
title_short Changes in the U.S. Primary Standards for the Air Kerma From Gamma-Ray Beams
title_sort changes in the u.s. primary standards for the air kerma from gamma-ray beams
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4847583/
https://www.ncbi.nlm.nih.gov/pubmed/27413615
http://dx.doi.org/10.6028/jres.108.031
work_keys_str_mv AT seltzerstephenm changesintheusprimarystandardsfortheairkermafromgammaraybeams
AT bergstrompaulm changesintheusprimarystandardsfortheairkermafromgammaraybeams