Cargando…
Development of a Standard Protocol for the Harmonic Analysis of Radial Pulse Wave and Assessing Its Reliability in Healthy Humans
This study was aimed to establish a standard protocol and to quantitatively assess the reliability of harmonic analysis of the radial pulse wave measured by a harmonic wave analyzer (TD01C system). Both intraobserver and interobserver assessments were conducted to investigate whether the values of h...
Formato: | Online Artículo Texto |
---|---|
Lenguaje: | English |
Publicado: |
IEEE
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4848080/ https://www.ncbi.nlm.nih.gov/pubmed/27170904 http://dx.doi.org/10.1109/JTEHM.2015.2490661 |
_version_ | 1782429296573284352 |
---|---|
collection | PubMed |
description | This study was aimed to establish a standard protocol and to quantitatively assess the reliability of harmonic analysis of the radial pulse wave measured by a harmonic wave analyzer (TD01C system). Both intraobserver and interobserver assessments were conducted to investigate whether the values of harmonics are stable in successive measurements. An intraclass correlation coefficient (ICC) and a Bland–Altman plot were used for this purpose. For the reliability assessments of the intraobserver and the interobserver, 22 subjects (mean age 45 ± 14 years; 14 males and 8 females) were enrolled. The first eleven harmonics of the radial pulse wave presented excellent repeatability ([Formula: see text] and [Formula: see text]) for the intraobserver assessment and high reproducibility (ICCs range from 0.83 to 0.96 and [Formula: see text]) for the interobserver assessment. The Bland–Altman plot indicated that more than 90% of harmonic values fell within two standard deviations of the mean difference. Thus, we concluded that the harmonic analysis of the radial pulse wave using the TD01C system is a feasible and reliable method to assess a hemodynamic characteristic in clinical trial. |
format | Online Article Text |
id | pubmed-4848080 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | IEEE |
record_format | MEDLINE/PubMed |
spelling | pubmed-48480802016-05-11 Development of a Standard Protocol for the Harmonic Analysis of Radial Pulse Wave and Assessing Its Reliability in Healthy Humans IEEE J Transl Eng Health Med Article This study was aimed to establish a standard protocol and to quantitatively assess the reliability of harmonic analysis of the radial pulse wave measured by a harmonic wave analyzer (TD01C system). Both intraobserver and interobserver assessments were conducted to investigate whether the values of harmonics are stable in successive measurements. An intraclass correlation coefficient (ICC) and a Bland–Altman plot were used for this purpose. For the reliability assessments of the intraobserver and the interobserver, 22 subjects (mean age 45 ± 14 years; 14 males and 8 females) were enrolled. The first eleven harmonics of the radial pulse wave presented excellent repeatability ([Formula: see text] and [Formula: see text]) for the intraobserver assessment and high reproducibility (ICCs range from 0.83 to 0.96 and [Formula: see text]) for the interobserver assessment. The Bland–Altman plot indicated that more than 90% of harmonic values fell within two standard deviations of the mean difference. Thus, we concluded that the harmonic analysis of the radial pulse wave using the TD01C system is a feasible and reliable method to assess a hemodynamic characteristic in clinical trial. IEEE 2015-10-14 /pmc/articles/PMC4848080/ /pubmed/27170904 http://dx.doi.org/10.1109/JTEHM.2015.2490661 Text en 2168-2372 © 2015 IEEE. Translations and content mining are permitted for academic research only. Personal use is also permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information. |
spellingShingle | Article Development of a Standard Protocol for the Harmonic Analysis of Radial Pulse Wave and Assessing Its Reliability in Healthy Humans |
title | Development of a Standard Protocol for the Harmonic Analysis of Radial Pulse Wave and Assessing Its Reliability in Healthy Humans |
title_full | Development of a Standard Protocol for the Harmonic Analysis of Radial Pulse Wave and Assessing Its Reliability in Healthy Humans |
title_fullStr | Development of a Standard Protocol for the Harmonic Analysis of Radial Pulse Wave and Assessing Its Reliability in Healthy Humans |
title_full_unstemmed | Development of a Standard Protocol for the Harmonic Analysis of Radial Pulse Wave and Assessing Its Reliability in Healthy Humans |
title_short | Development of a Standard Protocol for the Harmonic Analysis of Radial Pulse Wave and Assessing Its Reliability in Healthy Humans |
title_sort | development of a standard protocol for the harmonic analysis of radial pulse wave and assessing its reliability in healthy humans |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4848080/ https://www.ncbi.nlm.nih.gov/pubmed/27170904 http://dx.doi.org/10.1109/JTEHM.2015.2490661 |
work_keys_str_mv | AT developmentofastandardprotocolfortheharmonicanalysisofradialpulsewaveandassessingitsreliabilityinhealthyhumans AT developmentofastandardprotocolfortheharmonicanalysisofradialpulsewaveandassessingitsreliabilityinhealthyhumans AT developmentofastandardprotocolfortheharmonicanalysisofradialpulsewaveandassessingitsreliabilityinhealthyhumans |