The Reliability of Pharyngeal High Resolution Manometry with Impedance for Derivation of Measures of Swallowing Function in Healthy Volunteers

Purpose. We evaluated the intra- and interrater agreement and test-retest reliability of analyst derivation of swallow function variables based on repeated high resolution manometry with impedance measurements. Methods. Five subjects swallowed 10 × 10 mL saline on two occasions one week apart produc...

Descripción completa

Detalles Bibliográficos
Autores principales: Omari, Taher I., Savilampi, Johanna, Kokkinn, Karmen, Schar, Mistyka, Lamvik, Kristin, Doeltgen, Sebastian, Cock, Charles
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4848412/
https://www.ncbi.nlm.nih.gov/pubmed/27190520
http://dx.doi.org/10.1155/2016/2718482
_version_ 1782429337563168768
author Omari, Taher I.
Savilampi, Johanna
Kokkinn, Karmen
Schar, Mistyka
Lamvik, Kristin
Doeltgen, Sebastian
Cock, Charles
author_facet Omari, Taher I.
Savilampi, Johanna
Kokkinn, Karmen
Schar, Mistyka
Lamvik, Kristin
Doeltgen, Sebastian
Cock, Charles
author_sort Omari, Taher I.
collection PubMed
description Purpose. We evaluated the intra- and interrater agreement and test-retest reliability of analyst derivation of swallow function variables based on repeated high resolution manometry with impedance measurements. Methods. Five subjects swallowed 10 × 10 mL saline on two occasions one week apart producing a database of 100 swallows. Swallows were repeat-analysed by six observers using software. Swallow variables were indicative of contractility, intrabolus pressure, and flow timing. Results. The average intraclass correlation coefficients (ICC) for intra- and interrater comparisons of all variable means showed substantial to excellent agreement (intrarater ICC 0.85–1.00; mean interrater ICC 0.77–1.00). Test-retest results were less reliable. ICC for test-retest comparisons ranged from slight to excellent depending on the class of variable. Contractility variables differed most in terms of test-retest reliability. Amongst contractility variables, UES basal pressure showed excellent test-retest agreement (mean ICC 0.94), measures of UES postrelaxation contractile pressure showed moderate to substantial test-retest agreement (mean Interrater ICC 0.47–0.67), and test-retest agreement of pharyngeal contractile pressure ranged from slight to substantial (mean Interrater ICC 0.15–0.61). Conclusions. Test-retest reliability of HRIM measures depends on the class of variable. Measures of bolus distension pressure and flow timing appear to be more test-retest reliable than measures of contractility.
format Online
Article
Text
id pubmed-4848412
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-48484122016-05-17 The Reliability of Pharyngeal High Resolution Manometry with Impedance for Derivation of Measures of Swallowing Function in Healthy Volunteers Omari, Taher I. Savilampi, Johanna Kokkinn, Karmen Schar, Mistyka Lamvik, Kristin Doeltgen, Sebastian Cock, Charles Int J Otolaryngol Research Article Purpose. We evaluated the intra- and interrater agreement and test-retest reliability of analyst derivation of swallow function variables based on repeated high resolution manometry with impedance measurements. Methods. Five subjects swallowed 10 × 10 mL saline on two occasions one week apart producing a database of 100 swallows. Swallows were repeat-analysed by six observers using software. Swallow variables were indicative of contractility, intrabolus pressure, and flow timing. Results. The average intraclass correlation coefficients (ICC) for intra- and interrater comparisons of all variable means showed substantial to excellent agreement (intrarater ICC 0.85–1.00; mean interrater ICC 0.77–1.00). Test-retest results were less reliable. ICC for test-retest comparisons ranged from slight to excellent depending on the class of variable. Contractility variables differed most in terms of test-retest reliability. Amongst contractility variables, UES basal pressure showed excellent test-retest agreement (mean ICC 0.94), measures of UES postrelaxation contractile pressure showed moderate to substantial test-retest agreement (mean Interrater ICC 0.47–0.67), and test-retest agreement of pharyngeal contractile pressure ranged from slight to substantial (mean Interrater ICC 0.15–0.61). Conclusions. Test-retest reliability of HRIM measures depends on the class of variable. Measures of bolus distension pressure and flow timing appear to be more test-retest reliable than measures of contractility. Hindawi Publishing Corporation 2016 2016-04-14 /pmc/articles/PMC4848412/ /pubmed/27190520 http://dx.doi.org/10.1155/2016/2718482 Text en Copyright © 2016 Taher I. Omari et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Omari, Taher I.
Savilampi, Johanna
Kokkinn, Karmen
Schar, Mistyka
Lamvik, Kristin
Doeltgen, Sebastian
Cock, Charles
The Reliability of Pharyngeal High Resolution Manometry with Impedance for Derivation of Measures of Swallowing Function in Healthy Volunteers
title The Reliability of Pharyngeal High Resolution Manometry with Impedance for Derivation of Measures of Swallowing Function in Healthy Volunteers
title_full The Reliability of Pharyngeal High Resolution Manometry with Impedance for Derivation of Measures of Swallowing Function in Healthy Volunteers
title_fullStr The Reliability of Pharyngeal High Resolution Manometry with Impedance for Derivation of Measures of Swallowing Function in Healthy Volunteers
title_full_unstemmed The Reliability of Pharyngeal High Resolution Manometry with Impedance for Derivation of Measures of Swallowing Function in Healthy Volunteers
title_short The Reliability of Pharyngeal High Resolution Manometry with Impedance for Derivation of Measures of Swallowing Function in Healthy Volunteers
title_sort reliability of pharyngeal high resolution manometry with impedance for derivation of measures of swallowing function in healthy volunteers
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4848412/
https://www.ncbi.nlm.nih.gov/pubmed/27190520
http://dx.doi.org/10.1155/2016/2718482
work_keys_str_mv AT omaritaheri thereliabilityofpharyngealhighresolutionmanometrywithimpedanceforderivationofmeasuresofswallowingfunctioninhealthyvolunteers
AT savilampijohanna thereliabilityofpharyngealhighresolutionmanometrywithimpedanceforderivationofmeasuresofswallowingfunctioninhealthyvolunteers
AT kokkinnkarmen thereliabilityofpharyngealhighresolutionmanometrywithimpedanceforderivationofmeasuresofswallowingfunctioninhealthyvolunteers
AT scharmistyka thereliabilityofpharyngealhighresolutionmanometrywithimpedanceforderivationofmeasuresofswallowingfunctioninhealthyvolunteers
AT lamvikkristin thereliabilityofpharyngealhighresolutionmanometrywithimpedanceforderivationofmeasuresofswallowingfunctioninhealthyvolunteers
AT doeltgensebastian thereliabilityofpharyngealhighresolutionmanometrywithimpedanceforderivationofmeasuresofswallowingfunctioninhealthyvolunteers
AT cockcharles thereliabilityofpharyngealhighresolutionmanometrywithimpedanceforderivationofmeasuresofswallowingfunctioninhealthyvolunteers
AT omaritaheri reliabilityofpharyngealhighresolutionmanometrywithimpedanceforderivationofmeasuresofswallowingfunctioninhealthyvolunteers
AT savilampijohanna reliabilityofpharyngealhighresolutionmanometrywithimpedanceforderivationofmeasuresofswallowingfunctioninhealthyvolunteers
AT kokkinnkarmen reliabilityofpharyngealhighresolutionmanometrywithimpedanceforderivationofmeasuresofswallowingfunctioninhealthyvolunteers
AT scharmistyka reliabilityofpharyngealhighresolutionmanometrywithimpedanceforderivationofmeasuresofswallowingfunctioninhealthyvolunteers
AT lamvikkristin reliabilityofpharyngealhighresolutionmanometrywithimpedanceforderivationofmeasuresofswallowingfunctioninhealthyvolunteers
AT doeltgensebastian reliabilityofpharyngealhighresolutionmanometrywithimpedanceforderivationofmeasuresofswallowingfunctioninhealthyvolunteers
AT cockcharles reliabilityofpharyngealhighresolutionmanometrywithimpedanceforderivationofmeasuresofswallowingfunctioninhealthyvolunteers