Cargando…
High-sensitivity intravascular photoacoustic imaging of lipid–laden plaque with a collinear catheter design
A highly sensitive catheter probe is critical to catheter-based intravascular photoacoustic imaging. Here, we present a photoacoustic catheter probe design on the basis of collinear alignment of the incident optical wave and the photoacoustically generated sound wave within a miniature catheter hous...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4848524/ https://www.ncbi.nlm.nih.gov/pubmed/27121894 http://dx.doi.org/10.1038/srep25236 |
_version_ | 1782429360316219392 |
---|---|
author | Cao, Yingchun Hui, Jie Kole, Ayeeshik Wang, Pu Yu, Qianhuan Chen, Weibiao Sturek, Michael Cheng, Ji-Xin |
author_facet | Cao, Yingchun Hui, Jie Kole, Ayeeshik Wang, Pu Yu, Qianhuan Chen, Weibiao Sturek, Michael Cheng, Ji-Xin |
author_sort | Cao, Yingchun |
collection | PubMed |
description | A highly sensitive catheter probe is critical to catheter-based intravascular photoacoustic imaging. Here, we present a photoacoustic catheter probe design on the basis of collinear alignment of the incident optical wave and the photoacoustically generated sound wave within a miniature catheter housing for the first time. Such collinear catheter design with an outer diameter of 1.6 mm provided highly efficient overlap between optical and acoustic waves over an imaging depth of >6 mm in D(2)O medium. Intravascular photoacoustic imaging of lipid-laden atherosclerotic plaque and perivascular fat was demonstrated, where a lab-built 500 Hz optical parametric oscillator outputting nanosecond optical pulses at a wavelength of 1.7 μm was used for overtone excitation of C-H bonds. In addition to intravascular imaging, the presented catheter design will benefit other photoacoustic applications such as needle-based intramuscular imaging. |
format | Online Article Text |
id | pubmed-4848524 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-48485242016-05-05 High-sensitivity intravascular photoacoustic imaging of lipid–laden plaque with a collinear catheter design Cao, Yingchun Hui, Jie Kole, Ayeeshik Wang, Pu Yu, Qianhuan Chen, Weibiao Sturek, Michael Cheng, Ji-Xin Sci Rep Article A highly sensitive catheter probe is critical to catheter-based intravascular photoacoustic imaging. Here, we present a photoacoustic catheter probe design on the basis of collinear alignment of the incident optical wave and the photoacoustically generated sound wave within a miniature catheter housing for the first time. Such collinear catheter design with an outer diameter of 1.6 mm provided highly efficient overlap between optical and acoustic waves over an imaging depth of >6 mm in D(2)O medium. Intravascular photoacoustic imaging of lipid-laden atherosclerotic plaque and perivascular fat was demonstrated, where a lab-built 500 Hz optical parametric oscillator outputting nanosecond optical pulses at a wavelength of 1.7 μm was used for overtone excitation of C-H bonds. In addition to intravascular imaging, the presented catheter design will benefit other photoacoustic applications such as needle-based intramuscular imaging. Nature Publishing Group 2016-04-28 /pmc/articles/PMC4848524/ /pubmed/27121894 http://dx.doi.org/10.1038/srep25236 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Cao, Yingchun Hui, Jie Kole, Ayeeshik Wang, Pu Yu, Qianhuan Chen, Weibiao Sturek, Michael Cheng, Ji-Xin High-sensitivity intravascular photoacoustic imaging of lipid–laden plaque with a collinear catheter design |
title | High-sensitivity intravascular photoacoustic imaging of lipid–laden plaque with a collinear catheter design |
title_full | High-sensitivity intravascular photoacoustic imaging of lipid–laden plaque with a collinear catheter design |
title_fullStr | High-sensitivity intravascular photoacoustic imaging of lipid–laden plaque with a collinear catheter design |
title_full_unstemmed | High-sensitivity intravascular photoacoustic imaging of lipid–laden plaque with a collinear catheter design |
title_short | High-sensitivity intravascular photoacoustic imaging of lipid–laden plaque with a collinear catheter design |
title_sort | high-sensitivity intravascular photoacoustic imaging of lipid–laden plaque with a collinear catheter design |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4848524/ https://www.ncbi.nlm.nih.gov/pubmed/27121894 http://dx.doi.org/10.1038/srep25236 |
work_keys_str_mv | AT caoyingchun highsensitivityintravascularphotoacousticimagingoflipidladenplaquewithacollinearcatheterdesign AT huijie highsensitivityintravascularphotoacousticimagingoflipidladenplaquewithacollinearcatheterdesign AT koleayeeshik highsensitivityintravascularphotoacousticimagingoflipidladenplaquewithacollinearcatheterdesign AT wangpu highsensitivityintravascularphotoacousticimagingoflipidladenplaquewithacollinearcatheterdesign AT yuqianhuan highsensitivityintravascularphotoacousticimagingoflipidladenplaquewithacollinearcatheterdesign AT chenweibiao highsensitivityintravascularphotoacousticimagingoflipidladenplaquewithacollinearcatheterdesign AT sturekmichael highsensitivityintravascularphotoacousticimagingoflipidladenplaquewithacollinearcatheterdesign AT chengjixin highsensitivityintravascularphotoacousticimagingoflipidladenplaquewithacollinearcatheterdesign |