Cargando…
Validation of the Filovirus Plaque Assay for Use in Preclinical Studies
A plaque assay for quantitating filoviruses in virus stocks, prepared viral challenge inocula and samples from research animals has recently been fully characterized and standardized for use across multiple institutions performing Biosafety Level 4 (BSL-4) studies. After standardization studies were...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4848606/ https://www.ncbi.nlm.nih.gov/pubmed/27110807 http://dx.doi.org/10.3390/v8040113 |
_version_ | 1782429378541518848 |
---|---|
author | Shurtleff, Amy C. Bloomfield, Holly A. Mort, Shannon Orr, Steven A. Audet, Brian Whitaker, Thomas Richards, Michelle J. Bavari, Sina |
author_facet | Shurtleff, Amy C. Bloomfield, Holly A. Mort, Shannon Orr, Steven A. Audet, Brian Whitaker, Thomas Richards, Michelle J. Bavari, Sina |
author_sort | Shurtleff, Amy C. |
collection | PubMed |
description | A plaque assay for quantitating filoviruses in virus stocks, prepared viral challenge inocula and samples from research animals has recently been fully characterized and standardized for use across multiple institutions performing Biosafety Level 4 (BSL-4) studies. After standardization studies were completed, Good Laboratory Practices (GLP)-compliant plaque assay method validation studies to demonstrate suitability for reliable and reproducible measurement of the Marburg Virus Angola (MARV) variant and Ebola Virus Kikwit (EBOV) variant commenced at the United States Army Medical Research Institute of Infectious Diseases (USAMRIID). The validation parameters tested included accuracy, precision, linearity, robustness, stability of the virus stocks and system suitability. The MARV and EBOV assays were confirmed to be accurate to ±0.5 log(10) PFU/mL. Repeatability precision, intermediate precision and reproducibility precision were sufficient to return viral titers with a coefficient of variation (%CV) of ≤30%, deemed acceptable variation for a cell-based bioassay. Intraclass correlation statistical techniques for the evaluation of the assay’s precision when the same plaques were quantitated by two analysts returned values passing the acceptance criteria, indicating high agreement between analysts. The assay was shown to be accurate and specific when run on Nonhuman Primates (NHP) serum and plasma samples diluted in plaque assay medium, with negligible matrix effects. Virus stocks demonstrated stability for freeze-thaw cycles typical of normal usage during assay retests. The results demonstrated that the EBOV and MARV plaque assays are accurate, precise and robust for filovirus titration in samples associated with the performance of GLP animal model studies. |
format | Online Article Text |
id | pubmed-4848606 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-48486062016-05-04 Validation of the Filovirus Plaque Assay for Use in Preclinical Studies Shurtleff, Amy C. Bloomfield, Holly A. Mort, Shannon Orr, Steven A. Audet, Brian Whitaker, Thomas Richards, Michelle J. Bavari, Sina Viruses Article A plaque assay for quantitating filoviruses in virus stocks, prepared viral challenge inocula and samples from research animals has recently been fully characterized and standardized for use across multiple institutions performing Biosafety Level 4 (BSL-4) studies. After standardization studies were completed, Good Laboratory Practices (GLP)-compliant plaque assay method validation studies to demonstrate suitability for reliable and reproducible measurement of the Marburg Virus Angola (MARV) variant and Ebola Virus Kikwit (EBOV) variant commenced at the United States Army Medical Research Institute of Infectious Diseases (USAMRIID). The validation parameters tested included accuracy, precision, linearity, robustness, stability of the virus stocks and system suitability. The MARV and EBOV assays were confirmed to be accurate to ±0.5 log(10) PFU/mL. Repeatability precision, intermediate precision and reproducibility precision were sufficient to return viral titers with a coefficient of variation (%CV) of ≤30%, deemed acceptable variation for a cell-based bioassay. Intraclass correlation statistical techniques for the evaluation of the assay’s precision when the same plaques were quantitated by two analysts returned values passing the acceptance criteria, indicating high agreement between analysts. The assay was shown to be accurate and specific when run on Nonhuman Primates (NHP) serum and plasma samples diluted in plaque assay medium, with negligible matrix effects. Virus stocks demonstrated stability for freeze-thaw cycles typical of normal usage during assay retests. The results demonstrated that the EBOV and MARV plaque assays are accurate, precise and robust for filovirus titration in samples associated with the performance of GLP animal model studies. MDPI 2016-04-21 /pmc/articles/PMC4848606/ /pubmed/27110807 http://dx.doi.org/10.3390/v8040113 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Shurtleff, Amy C. Bloomfield, Holly A. Mort, Shannon Orr, Steven A. Audet, Brian Whitaker, Thomas Richards, Michelle J. Bavari, Sina Validation of the Filovirus Plaque Assay for Use in Preclinical Studies |
title | Validation of the Filovirus Plaque Assay for Use in Preclinical Studies |
title_full | Validation of the Filovirus Plaque Assay for Use in Preclinical Studies |
title_fullStr | Validation of the Filovirus Plaque Assay for Use in Preclinical Studies |
title_full_unstemmed | Validation of the Filovirus Plaque Assay for Use in Preclinical Studies |
title_short | Validation of the Filovirus Plaque Assay for Use in Preclinical Studies |
title_sort | validation of the filovirus plaque assay for use in preclinical studies |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4848606/ https://www.ncbi.nlm.nih.gov/pubmed/27110807 http://dx.doi.org/10.3390/v8040113 |
work_keys_str_mv | AT shurtleffamyc validationofthefilovirusplaqueassayforuseinpreclinicalstudies AT bloomfieldhollya validationofthefilovirusplaqueassayforuseinpreclinicalstudies AT mortshannon validationofthefilovirusplaqueassayforuseinpreclinicalstudies AT orrstevena validationofthefilovirusplaqueassayforuseinpreclinicalstudies AT audetbrian validationofthefilovirusplaqueassayforuseinpreclinicalstudies AT whitakerthomas validationofthefilovirusplaqueassayforuseinpreclinicalstudies AT richardsmichellej validationofthefilovirusplaqueassayforuseinpreclinicalstudies AT bavarisina validationofthefilovirusplaqueassayforuseinpreclinicalstudies |