Cargando…
Design and Performance of Laser-Pumped Cs-Magnetometers for the Planned UCN EDM Experiment at PSI
We designed laser-pumped cesium vapor magnetometers in the M(x) configuration for the control and stabilization of magnetic field fluctuations and gradients in a new experiment searching for a permanent electric dipole moment of the neutron. The intrinsic sensitivity of the device was determined to...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
2005
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4849593/ https://www.ncbi.nlm.nih.gov/pubmed/27308118 |
_version_ | 1782429557659271168 |
---|---|
author | Groeger, S. Bison, G. Weis, A. |
author_facet | Groeger, S. Bison, G. Weis, A. |
author_sort | Groeger, S. |
collection | PubMed |
description | We designed laser-pumped cesium vapor magnetometers in the M(x) configuration for the control and stabilization of magnetic field fluctuations and gradients in a new experiment searching for a permanent electric dipole moment of the neutron. The intrinsic sensitivity of the device was determined to be 30 fT in a measurement bandwidth of 1 Hz, limited by laser noise. In the shot noise limit the magnetometer can reach a sensitivity of 7 fT for 1 s integration time. Test measurements of the stability of a 2 µT magnetic field in a threefold magnetic shield have revealed fluctuations on the order of 200 fT to 300 fT with integration times in the range of 2 s to 100 s. Those fluctuations were traced back to the stability of the power supply used to generate the magnetic field. The laser-pumped magnetometer fulfills the requirements set by the planned neutron electric dipole moment experiment. |
format | Online Article Text |
id | pubmed-4849593 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2005 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-48495932016-06-15 Design and Performance of Laser-Pumped Cs-Magnetometers for the Planned UCN EDM Experiment at PSI Groeger, S. Bison, G. Weis, A. J Res Natl Inst Stand Technol Article We designed laser-pumped cesium vapor magnetometers in the M(x) configuration for the control and stabilization of magnetic field fluctuations and gradients in a new experiment searching for a permanent electric dipole moment of the neutron. The intrinsic sensitivity of the device was determined to be 30 fT in a measurement bandwidth of 1 Hz, limited by laser noise. In the shot noise limit the magnetometer can reach a sensitivity of 7 fT for 1 s integration time. Test measurements of the stability of a 2 µT magnetic field in a threefold magnetic shield have revealed fluctuations on the order of 200 fT to 300 fT with integration times in the range of 2 s to 100 s. Those fluctuations were traced back to the stability of the power supply used to generate the magnetic field. The laser-pumped magnetometer fulfills the requirements set by the planned neutron electric dipole moment experiment. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2005 2005-06-01 /pmc/articles/PMC4849593/ /pubmed/27308118 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Groeger, S. Bison, G. Weis, A. Design and Performance of Laser-Pumped Cs-Magnetometers for the Planned UCN EDM Experiment at PSI |
title | Design and Performance of Laser-Pumped Cs-Magnetometers for the Planned UCN EDM Experiment at PSI |
title_full | Design and Performance of Laser-Pumped Cs-Magnetometers for the Planned UCN EDM Experiment at PSI |
title_fullStr | Design and Performance of Laser-Pumped Cs-Magnetometers for the Planned UCN EDM Experiment at PSI |
title_full_unstemmed | Design and Performance of Laser-Pumped Cs-Magnetometers for the Planned UCN EDM Experiment at PSI |
title_short | Design and Performance of Laser-Pumped Cs-Magnetometers for the Planned UCN EDM Experiment at PSI |
title_sort | design and performance of laser-pumped cs-magnetometers for the planned ucn edm experiment at psi |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4849593/ https://www.ncbi.nlm.nih.gov/pubmed/27308118 |
work_keys_str_mv | AT groegers designandperformanceoflaserpumpedcsmagnetometersfortheplanneducnedmexperimentatpsi AT bisong designandperformanceoflaserpumpedcsmagnetometersfortheplanneducnedmexperimentatpsi AT weisa designandperformanceoflaserpumpedcsmagnetometersfortheplanneducnedmexperimentatpsi |