Cargando…

Measurement of the Coherent Neutron Scattering Length of (3)He

By means of neutron interferometry the s-wave neutron scattering length of the (3)He nucleus was re-measured at the Institut Laue-Langevin (ILL). Using a skew symmetrical perfect crystal Si-interferometer and a linear twin chamber cell, false phase shifts due to sample misalignment were reduced to a...

Descripción completa

Detalles Bibliográficos
Autores principales: Ketter, W., Heil, W., Badurek, G., Baron, M., Loidl, R., Rauch, H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2005
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4849595/
https://www.ncbi.nlm.nih.gov/pubmed/27308129
_version_ 1782429558103867392
author Ketter, W.
Heil, W.
Badurek, G.
Baron, M.
Loidl, R.
Rauch, H.
author_facet Ketter, W.
Heil, W.
Badurek, G.
Baron, M.
Loidl, R.
Rauch, H.
author_sort Ketter, W.
collection PubMed
description By means of neutron interferometry the s-wave neutron scattering length of the (3)He nucleus was re-measured at the Institut Laue-Langevin (ILL). Using a skew symmetrical perfect crystal Si-interferometer and a linear twin chamber cell, false phase shifts due to sample misalignment were reduced to a negligible level. Simulation calculations suggest an asymmetrically alternating measuring sequence in order to compensate for systematic errors caused by thermal phase drifts. There is evidence in the experiment’s data that this procedure is indeed effective. The neutron refractive index in terms of Sears’ exact expression for the scattering amplitude has been analyzed in order to evaluate the measured phase shifts. The result of our measurement, b′(c) = (6.000 ± 0.009) fm, shows a deviation towards a greater value compared to the presently accepted value of b′(c) = (5.74 ± 0.07) fm, confirming the observation of the partner experiment at NIST. On the other hand, the results of both precision measurements at NIST and ILL exhibit a serious 12σ (12 standard uncertainties) deviation, the reason for which is not clear yet.
format Online
Article
Text
id pubmed-4849595
institution National Center for Biotechnology Information
language English
publishDate 2005
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-48495952016-06-15 Measurement of the Coherent Neutron Scattering Length of (3)He Ketter, W. Heil, W. Badurek, G. Baron, M. Loidl, R. Rauch, H. J Res Natl Inst Stand Technol Article By means of neutron interferometry the s-wave neutron scattering length of the (3)He nucleus was re-measured at the Institut Laue-Langevin (ILL). Using a skew symmetrical perfect crystal Si-interferometer and a linear twin chamber cell, false phase shifts due to sample misalignment were reduced to a negligible level. Simulation calculations suggest an asymmetrically alternating measuring sequence in order to compensate for systematic errors caused by thermal phase drifts. There is evidence in the experiment’s data that this procedure is indeed effective. The neutron refractive index in terms of Sears’ exact expression for the scattering amplitude has been analyzed in order to evaluate the measured phase shifts. The result of our measurement, b′(c) = (6.000 ± 0.009) fm, shows a deviation towards a greater value compared to the presently accepted value of b′(c) = (5.74 ± 0.07) fm, confirming the observation of the partner experiment at NIST. On the other hand, the results of both precision measurements at NIST and ILL exhibit a serious 12σ (12 standard uncertainties) deviation, the reason for which is not clear yet. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2005 2005-06-01 /pmc/articles/PMC4849595/ /pubmed/27308129 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Ketter, W.
Heil, W.
Badurek, G.
Baron, M.
Loidl, R.
Rauch, H.
Measurement of the Coherent Neutron Scattering Length of (3)He
title Measurement of the Coherent Neutron Scattering Length of (3)He
title_full Measurement of the Coherent Neutron Scattering Length of (3)He
title_fullStr Measurement of the Coherent Neutron Scattering Length of (3)He
title_full_unstemmed Measurement of the Coherent Neutron Scattering Length of (3)He
title_short Measurement of the Coherent Neutron Scattering Length of (3)He
title_sort measurement of the coherent neutron scattering length of (3)he
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4849595/
https://www.ncbi.nlm.nih.gov/pubmed/27308129
work_keys_str_mv AT ketterw measurementofthecoherentneutronscatteringlengthof3he
AT heilw measurementofthecoherentneutronscatteringlengthof3he
AT badurekg measurementofthecoherentneutronscatteringlengthof3he
AT baronm measurementofthecoherentneutronscatteringlengthof3he
AT loidlr measurementofthecoherentneutronscatteringlengthof3he
AT rauchh measurementofthecoherentneutronscatteringlengthof3he