Cargando…
Removal of displaced double flanged metal stent in walled-off necrosis by endoscopic ultrasonography
Endoscopic ultrasonography (EUS)-guided walled-off necrosis drainage using a double flanged metal stent was reported for satisfactory drainage and endoscopic necrosectomy. High complication rates related to stent migration are reported. This is the first report of the removal of a displaced, double...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4850793/ https://www.ncbi.nlm.nih.gov/pubmed/27080613 http://dx.doi.org/10.4103/2303-9027.180479 |
_version_ | 1782429718657630208 |
---|---|
author | Guo, Jintao Liu, Zhijun Sun, Siyu Liu, Xiang Wang, Sheng |
author_facet | Guo, Jintao Liu, Zhijun Sun, Siyu Liu, Xiang Wang, Sheng |
author_sort | Guo, Jintao |
collection | PubMed |
description | Endoscopic ultrasonography (EUS)-guided walled-off necrosis drainage using a double flanged metal stent was reported for satisfactory drainage and endoscopic necrosectomy. High complication rates related to stent migration are reported. This is the first report of the removal of a displaced, double flanged metal stent in walled-off necrosis by EUS. The patient was a 62-year-old male who was suffering from mild midepigastric abdominal pain. A double flanged metal stent had been placed in our endoscopy center 8 weeks before presentation. Computed tomography demonstrated complete resolution of the walled-off necrosis; however, the stent migrated into the cyst. We dislodged the stent using forceps with real-time endosonography. In conclusion, Follow-up is important for patients with a double flanged metal stent, specifically with regards to postprocedural stent migration. |
format | Online Article Text |
id | pubmed-4850793 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-48507932016-05-03 Removal of displaced double flanged metal stent in walled-off necrosis by endoscopic ultrasonography Guo, Jintao Liu, Zhijun Sun, Siyu Liu, Xiang Wang, Sheng Endosc Ultrasound Case Report Endoscopic ultrasonography (EUS)-guided walled-off necrosis drainage using a double flanged metal stent was reported for satisfactory drainage and endoscopic necrosectomy. High complication rates related to stent migration are reported. This is the first report of the removal of a displaced, double flanged metal stent in walled-off necrosis by EUS. The patient was a 62-year-old male who was suffering from mild midepigastric abdominal pain. A double flanged metal stent had been placed in our endoscopy center 8 weeks before presentation. Computed tomography demonstrated complete resolution of the walled-off necrosis; however, the stent migrated into the cyst. We dislodged the stent using forceps with real-time endosonography. In conclusion, Follow-up is important for patients with a double flanged metal stent, specifically with regards to postprocedural stent migration. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC4850793/ /pubmed/27080613 http://dx.doi.org/10.4103/2303-9027.180479 Text en Copyright: © 2016 Spring Media Publishing Co. Ltd http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Case Report Guo, Jintao Liu, Zhijun Sun, Siyu Liu, Xiang Wang, Sheng Removal of displaced double flanged metal stent in walled-off necrosis by endoscopic ultrasonography |
title | Removal of displaced double flanged metal stent in walled-off necrosis by endoscopic ultrasonography |
title_full | Removal of displaced double flanged metal stent in walled-off necrosis by endoscopic ultrasonography |
title_fullStr | Removal of displaced double flanged metal stent in walled-off necrosis by endoscopic ultrasonography |
title_full_unstemmed | Removal of displaced double flanged metal stent in walled-off necrosis by endoscopic ultrasonography |
title_short | Removal of displaced double flanged metal stent in walled-off necrosis by endoscopic ultrasonography |
title_sort | removal of displaced double flanged metal stent in walled-off necrosis by endoscopic ultrasonography |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4850793/ https://www.ncbi.nlm.nih.gov/pubmed/27080613 http://dx.doi.org/10.4103/2303-9027.180479 |
work_keys_str_mv | AT guojintao removalofdisplaceddoubleflangedmetalstentinwalledoffnecrosisbyendoscopicultrasonography AT liuzhijun removalofdisplaceddoubleflangedmetalstentinwalledoffnecrosisbyendoscopicultrasonography AT sunsiyu removalofdisplaceddoubleflangedmetalstentinwalledoffnecrosisbyendoscopicultrasonography AT liuxiang removalofdisplaceddoubleflangedmetalstentinwalledoffnecrosisbyendoscopicultrasonography AT wangsheng removalofdisplaceddoubleflangedmetalstentinwalledoffnecrosisbyendoscopicultrasonography |