Cargando…
Optical Riblet Sensor: Beam Parameter Requirements for the Probing Laser Source
Beam parameters of a probing laser source in an optical riblet sensor are studied by considering the high demands on a sensors’ precision and reliability for the determination of deviations of the geometrical shape of a riblet. Mandatory requirements, such as minimum intensity and light polarization...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4850972/ https://www.ncbi.nlm.nih.gov/pubmed/27043567 http://dx.doi.org/10.3390/s16040458 |
_version_ | 1782429747321503744 |
---|---|
author | Tschentscher, Juliane Hochheim, Sven Brüning, Hauke Brune, Kai Voit, Kay-Michael Imlau, Mirco |
author_facet | Tschentscher, Juliane Hochheim, Sven Brüning, Hauke Brune, Kai Voit, Kay-Michael Imlau, Mirco |
author_sort | Tschentscher, Juliane |
collection | PubMed |
description | Beam parameters of a probing laser source in an optical riblet sensor are studied by considering the high demands on a sensors’ precision and reliability for the determination of deviations of the geometrical shape of a riblet. Mandatory requirements, such as minimum intensity and light polarization, are obtained by means of detailed inspection of the optical response of the riblet using ray and wave optics; the impact of wavelength is studied. Novel measures for analyzing the riblet shape without the necessity of a measurement with a reference sample are derived; reference values for an ideal riblet structure obtained with the optical riblet sensor are given. The application of a low-cost, frequency-doubled Nd:YVO [Formula: see text] laser pointer sufficient to serve as a reliable laser source in an appropriate optical riblet sensor is discussed. |
format | Online Article Text |
id | pubmed-4850972 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-48509722016-05-04 Optical Riblet Sensor: Beam Parameter Requirements for the Probing Laser Source Tschentscher, Juliane Hochheim, Sven Brüning, Hauke Brune, Kai Voit, Kay-Michael Imlau, Mirco Sensors (Basel) Article Beam parameters of a probing laser source in an optical riblet sensor are studied by considering the high demands on a sensors’ precision and reliability for the determination of deviations of the geometrical shape of a riblet. Mandatory requirements, such as minimum intensity and light polarization, are obtained by means of detailed inspection of the optical response of the riblet using ray and wave optics; the impact of wavelength is studied. Novel measures for analyzing the riblet shape without the necessity of a measurement with a reference sample are derived; reference values for an ideal riblet structure obtained with the optical riblet sensor are given. The application of a low-cost, frequency-doubled Nd:YVO [Formula: see text] laser pointer sufficient to serve as a reliable laser source in an appropriate optical riblet sensor is discussed. MDPI 2016-03-30 /pmc/articles/PMC4850972/ /pubmed/27043567 http://dx.doi.org/10.3390/s16040458 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Tschentscher, Juliane Hochheim, Sven Brüning, Hauke Brune, Kai Voit, Kay-Michael Imlau, Mirco Optical Riblet Sensor: Beam Parameter Requirements for the Probing Laser Source |
title | Optical Riblet Sensor: Beam Parameter Requirements for the Probing Laser Source |
title_full | Optical Riblet Sensor: Beam Parameter Requirements for the Probing Laser Source |
title_fullStr | Optical Riblet Sensor: Beam Parameter Requirements for the Probing Laser Source |
title_full_unstemmed | Optical Riblet Sensor: Beam Parameter Requirements for the Probing Laser Source |
title_short | Optical Riblet Sensor: Beam Parameter Requirements for the Probing Laser Source |
title_sort | optical riblet sensor: beam parameter requirements for the probing laser source |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4850972/ https://www.ncbi.nlm.nih.gov/pubmed/27043567 http://dx.doi.org/10.3390/s16040458 |
work_keys_str_mv | AT tschentscherjuliane opticalribletsensorbeamparameterrequirementsfortheprobinglasersource AT hochheimsven opticalribletsensorbeamparameterrequirementsfortheprobinglasersource AT bruninghauke opticalribletsensorbeamparameterrequirementsfortheprobinglasersource AT brunekai opticalribletsensorbeamparameterrequirementsfortheprobinglasersource AT voitkaymichael opticalribletsensorbeamparameterrequirementsfortheprobinglasersource AT imlaumirco opticalribletsensorbeamparameterrequirementsfortheprobinglasersource |