Cargando…

Towards Real-Time Detection of Freezing of Gait Using Wavelet Transform on Wireless Accelerometer Data

Injuries associated with fall incidences continue to pose a significant burden to persons with Parkinson’s disease (PD) both in terms of human suffering and economic loss. Freezing of gait (FOG), which is one of the symptoms of PD, is a common cause of falls in this population. Although a significan...

Descripción completa

Detalles Bibliográficos
Autores principales: Rezvanian, Saba, Lockhart, Thurmon E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4850989/
https://www.ncbi.nlm.nih.gov/pubmed/27049389
http://dx.doi.org/10.3390/s16040475
_version_ 1782429751164534784
author Rezvanian, Saba
Lockhart, Thurmon E.
author_facet Rezvanian, Saba
Lockhart, Thurmon E.
author_sort Rezvanian, Saba
collection PubMed
description Injuries associated with fall incidences continue to pose a significant burden to persons with Parkinson’s disease (PD) both in terms of human suffering and economic loss. Freezing of gait (FOG), which is one of the symptoms of PD, is a common cause of falls in this population. Although a significant amount of work has been performed to characterize/detect FOG using both qualitative and quantitative methods, there remains paucity of data regarding real-time detection of FOG, such as the requirements for minimum sensor nodes, sensor placement locations, and appropriate sampling period and update time. Here, the continuous wavelet transform (CWT) is employed to define an index for correctly identifying FOG. Since the CWT method uses both time and frequency components of a waveform in comparison to other methods utilizing only the frequency component, we hypothesized that using this method could lead to a significant improvement in the accuracy of FOG detection. We tested the proposed index on the data of 10 PD patients who experience FOG. Two hundred and thirty seven (237) FOG events were identified by the physiotherapists. The results show that the index could discriminate FOG in the anterior–posterior axis better than other two axes, and is robust to the update time variability. These results suggest that real time detection of FOG may be realized by using CWT of a single shank sensor with window size of 2 s and update time of 1 s (82.1% and 77.1% for the sensitivity and specificity, respectively). Although implicated, future studies should examine the utility of this method in real-time detection of FOG.
format Online
Article
Text
id pubmed-4850989
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-48509892016-05-04 Towards Real-Time Detection of Freezing of Gait Using Wavelet Transform on Wireless Accelerometer Data Rezvanian, Saba Lockhart, Thurmon E. Sensors (Basel) Article Injuries associated with fall incidences continue to pose a significant burden to persons with Parkinson’s disease (PD) both in terms of human suffering and economic loss. Freezing of gait (FOG), which is one of the symptoms of PD, is a common cause of falls in this population. Although a significant amount of work has been performed to characterize/detect FOG using both qualitative and quantitative methods, there remains paucity of data regarding real-time detection of FOG, such as the requirements for minimum sensor nodes, sensor placement locations, and appropriate sampling period and update time. Here, the continuous wavelet transform (CWT) is employed to define an index for correctly identifying FOG. Since the CWT method uses both time and frequency components of a waveform in comparison to other methods utilizing only the frequency component, we hypothesized that using this method could lead to a significant improvement in the accuracy of FOG detection. We tested the proposed index on the data of 10 PD patients who experience FOG. Two hundred and thirty seven (237) FOG events were identified by the physiotherapists. The results show that the index could discriminate FOG in the anterior–posterior axis better than other two axes, and is robust to the update time variability. These results suggest that real time detection of FOG may be realized by using CWT of a single shank sensor with window size of 2 s and update time of 1 s (82.1% and 77.1% for the sensitivity and specificity, respectively). Although implicated, future studies should examine the utility of this method in real-time detection of FOG. MDPI 2016-04-02 /pmc/articles/PMC4850989/ /pubmed/27049389 http://dx.doi.org/10.3390/s16040475 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Rezvanian, Saba
Lockhart, Thurmon E.
Towards Real-Time Detection of Freezing of Gait Using Wavelet Transform on Wireless Accelerometer Data
title Towards Real-Time Detection of Freezing of Gait Using Wavelet Transform on Wireless Accelerometer Data
title_full Towards Real-Time Detection of Freezing of Gait Using Wavelet Transform on Wireless Accelerometer Data
title_fullStr Towards Real-Time Detection of Freezing of Gait Using Wavelet Transform on Wireless Accelerometer Data
title_full_unstemmed Towards Real-Time Detection of Freezing of Gait Using Wavelet Transform on Wireless Accelerometer Data
title_short Towards Real-Time Detection of Freezing of Gait Using Wavelet Transform on Wireless Accelerometer Data
title_sort towards real-time detection of freezing of gait using wavelet transform on wireless accelerometer data
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4850989/
https://www.ncbi.nlm.nih.gov/pubmed/27049389
http://dx.doi.org/10.3390/s16040475
work_keys_str_mv AT rezvaniansaba towardsrealtimedetectionoffreezingofgaitusingwavelettransformonwirelessaccelerometerdata
AT lockhartthurmone towardsrealtimedetectionoffreezingofgaitusingwavelettransformonwirelessaccelerometerdata