Cargando…

Dosimetric evaluation of X-ray examinations of paranasal sinuses in pediatric patients

OBJECTIVE: To estimate the entrance surface air kerma (K(a,e)) and air kerma in the region of radiosensitive organs in radiographs of pediatric paranasal sinuses. MATERIALS AND METHODS: Patient data and irradiation parameters were collected in examinations of the paranasal sinuses in children from 0...

Descripción completa

Detalles Bibliográficos
Autores principales: Cantalupo, Beatriz de Lucena Villa-Chan, Xavier, Aline Carvalho da Silva, da Silva, Clemanzy Mariano Leandro, Andrade, Marcos Ely Almeida, de Barros, Vinícius Saito Monteiro, Khoury, Helen Jamil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Colégio Brasileiro de Radiologia e Diagnóstico por Imagem 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4851475/
https://www.ncbi.nlm.nih.gov/pubmed/27141129
http://dx.doi.org/10.1590/0100-3984.2015.0081
_version_ 1782429820900081664
author Cantalupo, Beatriz de Lucena Villa-Chan
Xavier, Aline Carvalho da Silva
da Silva, Clemanzy Mariano Leandro
Andrade, Marcos Ely Almeida
de Barros, Vinícius Saito Monteiro
Khoury, Helen Jamil
author_facet Cantalupo, Beatriz de Lucena Villa-Chan
Xavier, Aline Carvalho da Silva
da Silva, Clemanzy Mariano Leandro
Andrade, Marcos Ely Almeida
de Barros, Vinícius Saito Monteiro
Khoury, Helen Jamil
author_sort Cantalupo, Beatriz de Lucena Villa-Chan
collection PubMed
description OBJECTIVE: To estimate the entrance surface air kerma (K(a,e)) and air kerma in the region of radiosensitive organs in radiographs of pediatric paranasal sinuses. MATERIALS AND METHODS: Patient data and irradiation parameters were collected in examinations of the paranasal sinuses in children from 0 to 15 years of age at two children's hospitals in the city of Recife, PE, Brazil. We estimated the K(a,e) using the X-ray tube outputs and selected parameters. To estimate the air kerma values in the regions of the eyes and thyroid, we used thermoluminescent dosimeters. RESULTS: The K(a,e) values ranged from 0.065 to 1.446 mGy in cavum radiographs, from 0.104 to 7.298 mGy in Caldwell views, and from 0.113 to 7.824 mGy in Waters views. Air kerma values in the region of the eyes ranged from 0.001 to 0.968 mGy in cavum radiographs and from 0.011 to 0.422 mGy in Caldwell and Waters views . In the thyroid region, air kerma values ranged from 0.005 to 0.932 mGy in cavum radiographs and from 0.002 to 0.972 mGy in Caldwell and Waters views. CONCLUSION: The radiation levels used at the institutions under study were higher than those recommended in international protocols. We recommend that interventions be initiated in order to reduce patient exposure to radiation and therefore the risks associated with radiological examination of the paranasal sinuses.
format Online
Article
Text
id pubmed-4851475
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
record_format MEDLINE/PubMed
spelling pubmed-48514752016-05-02 Dosimetric evaluation of X-ray examinations of paranasal sinuses in pediatric patients Cantalupo, Beatriz de Lucena Villa-Chan Xavier, Aline Carvalho da Silva da Silva, Clemanzy Mariano Leandro Andrade, Marcos Ely Almeida de Barros, Vinícius Saito Monteiro Khoury, Helen Jamil Radiol Bras Artigos Originais OBJECTIVE: To estimate the entrance surface air kerma (K(a,e)) and air kerma in the region of radiosensitive organs in radiographs of pediatric paranasal sinuses. MATERIALS AND METHODS: Patient data and irradiation parameters were collected in examinations of the paranasal sinuses in children from 0 to 15 years of age at two children's hospitals in the city of Recife, PE, Brazil. We estimated the K(a,e) using the X-ray tube outputs and selected parameters. To estimate the air kerma values in the regions of the eyes and thyroid, we used thermoluminescent dosimeters. RESULTS: The K(a,e) values ranged from 0.065 to 1.446 mGy in cavum radiographs, from 0.104 to 7.298 mGy in Caldwell views, and from 0.113 to 7.824 mGy in Waters views. Air kerma values in the region of the eyes ranged from 0.001 to 0.968 mGy in cavum radiographs and from 0.011 to 0.422 mGy in Caldwell and Waters views . In the thyroid region, air kerma values ranged from 0.005 to 0.932 mGy in cavum radiographs and from 0.002 to 0.972 mGy in Caldwell and Waters views. CONCLUSION: The radiation levels used at the institutions under study were higher than those recommended in international protocols. We recommend that interventions be initiated in order to reduce patient exposure to radiation and therefore the risks associated with radiological examination of the paranasal sinuses. Colégio Brasileiro de Radiologia e Diagnóstico por Imagem 2016 /pmc/articles/PMC4851475/ /pubmed/27141129 http://dx.doi.org/10.1590/0100-3984.2015.0081 Text en
spellingShingle Artigos Originais
Cantalupo, Beatriz de Lucena Villa-Chan
Xavier, Aline Carvalho da Silva
da Silva, Clemanzy Mariano Leandro
Andrade, Marcos Ely Almeida
de Barros, Vinícius Saito Monteiro
Khoury, Helen Jamil
Dosimetric evaluation of X-ray examinations of paranasal sinuses in pediatric patients
title Dosimetric evaluation of X-ray examinations of paranasal sinuses in pediatric patients
title_full Dosimetric evaluation of X-ray examinations of paranasal sinuses in pediatric patients
title_fullStr Dosimetric evaluation of X-ray examinations of paranasal sinuses in pediatric patients
title_full_unstemmed Dosimetric evaluation of X-ray examinations of paranasal sinuses in pediatric patients
title_short Dosimetric evaluation of X-ray examinations of paranasal sinuses in pediatric patients
title_sort dosimetric evaluation of x-ray examinations of paranasal sinuses in pediatric patients
topic Artigos Originais
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4851475/
https://www.ncbi.nlm.nih.gov/pubmed/27141129
http://dx.doi.org/10.1590/0100-3984.2015.0081
work_keys_str_mv AT cantalupobeatrizdelucenavillachan dosimetricevaluationofxrayexaminationsofparanasalsinusesinpediatricpatients
AT xavieralinecarvalhodasilva dosimetricevaluationofxrayexaminationsofparanasalsinusesinpediatricpatients
AT dasilvaclemanzymarianoleandro dosimetricevaluationofxrayexaminationsofparanasalsinusesinpediatricpatients
AT andrademarcoselyalmeida dosimetricevaluationofxrayexaminationsofparanasalsinusesinpediatricpatients
AT debarrosviniciussaitomonteiro dosimetricevaluationofxrayexaminationsofparanasalsinusesinpediatricpatients
AT khouryhelenjamil dosimetricevaluationofxrayexaminationsofparanasalsinusesinpediatricpatients