Cargando…

The dark art of light measurement: accurate radiometry for low-level light therapy

Lasers and light-emitting diodes are used for a range of biomedical applications with many studies reporting their beneficial effects. However, three main concerns exist regarding much of the low-level light therapy (LLLT) or photobiomodulation literature; (1) incomplete, inaccurate and unverified i...

Descripción completa

Detalles Bibliográficos
Autores principales: Hadis, Mohammed A., Zainal, Siti A., Holder, Michelle J., Carroll, James D., Cooper, Paul R., Milward, Michael R., Palin, William M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer London 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4851696/
https://www.ncbi.nlm.nih.gov/pubmed/26964800
http://dx.doi.org/10.1007/s10103-016-1914-y
_version_ 1782429846444441600
author Hadis, Mohammed A.
Zainal, Siti A.
Holder, Michelle J.
Carroll, James D.
Cooper, Paul R.
Milward, Michael R.
Palin, William M.
author_facet Hadis, Mohammed A.
Zainal, Siti A.
Holder, Michelle J.
Carroll, James D.
Cooper, Paul R.
Milward, Michael R.
Palin, William M.
author_sort Hadis, Mohammed A.
collection PubMed
description Lasers and light-emitting diodes are used for a range of biomedical applications with many studies reporting their beneficial effects. However, three main concerns exist regarding much of the low-level light therapy (LLLT) or photobiomodulation literature; (1) incomplete, inaccurate and unverified irradiation parameters, (2) miscalculation of ‘dose,’ and (3) the misuse of appropriate light property terminology. The aim of this systematic review was to assess where, and to what extent, these inadequacies exist and to provide an overview of ‘best practice’ in light measurement methods and importance of correct light measurement. A review of recent relevant literature was performed in PubMed using the terms LLLT and photobiomodulation (March 2014–March 2015) to investigate the contemporary information available in LLLT and photobiomodulation literature in terms of reporting light properties and irradiation parameters. A total of 74 articles formed the basis of this systematic review. Although most articles reported beneficial effects following LLLT, the majority contained no information in terms of how light was measured (73 %) and relied on manufacturer-stated values. For all papers reviewed, missing information for specific light parameters included wavelength (3 %), light source type (8 %), power (41 %), pulse frequency (52 %), beam area (40 %), irradiance (43 %), exposure time (16 %), radiant energy (74 %) and fluence (16 %). Frequent use of incorrect terminology was also observed within the reviewed literature. A poor understanding of photophysics is evident as a significant number of papers neglected to report or misreported important radiometric data. These errors affect repeatability and reliability of studies shared between scientists, manufacturers and clinicians and could degrade efficacy of patient treatments. Researchers need a physicist or appropriately skilled engineer on the team, and manuscript reviewers should reject papers that do not report beam measurement methods and all ten key parameters: wavelength, power, irradiation time, beam area (at the skin or culture surface; this is not necessarily the same size as the aperture), radiant energy, radiant exposure, pulse parameters, number of treatments, interval between treatments and anatomical location. Inclusion of these parameters will improve the information available to compare and contrast study outcomes and improve repeatability, reliability of studies.
format Online
Article
Text
id pubmed-4851696
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer London
record_format MEDLINE/PubMed
spelling pubmed-48516962016-05-19 The dark art of light measurement: accurate radiometry for low-level light therapy Hadis, Mohammed A. Zainal, Siti A. Holder, Michelle J. Carroll, James D. Cooper, Paul R. Milward, Michael R. Palin, William M. Lasers Med Sci Review Article Lasers and light-emitting diodes are used for a range of biomedical applications with many studies reporting their beneficial effects. However, three main concerns exist regarding much of the low-level light therapy (LLLT) or photobiomodulation literature; (1) incomplete, inaccurate and unverified irradiation parameters, (2) miscalculation of ‘dose,’ and (3) the misuse of appropriate light property terminology. The aim of this systematic review was to assess where, and to what extent, these inadequacies exist and to provide an overview of ‘best practice’ in light measurement methods and importance of correct light measurement. A review of recent relevant literature was performed in PubMed using the terms LLLT and photobiomodulation (March 2014–March 2015) to investigate the contemporary information available in LLLT and photobiomodulation literature in terms of reporting light properties and irradiation parameters. A total of 74 articles formed the basis of this systematic review. Although most articles reported beneficial effects following LLLT, the majority contained no information in terms of how light was measured (73 %) and relied on manufacturer-stated values. For all papers reviewed, missing information for specific light parameters included wavelength (3 %), light source type (8 %), power (41 %), pulse frequency (52 %), beam area (40 %), irradiance (43 %), exposure time (16 %), radiant energy (74 %) and fluence (16 %). Frequent use of incorrect terminology was also observed within the reviewed literature. A poor understanding of photophysics is evident as a significant number of papers neglected to report or misreported important radiometric data. These errors affect repeatability and reliability of studies shared between scientists, manufacturers and clinicians and could degrade efficacy of patient treatments. Researchers need a physicist or appropriately skilled engineer on the team, and manuscript reviewers should reject papers that do not report beam measurement methods and all ten key parameters: wavelength, power, irradiation time, beam area (at the skin or culture surface; this is not necessarily the same size as the aperture), radiant energy, radiant exposure, pulse parameters, number of treatments, interval between treatments and anatomical location. Inclusion of these parameters will improve the information available to compare and contrast study outcomes and improve repeatability, reliability of studies. Springer London 2016-03-10 2016 /pmc/articles/PMC4851696/ /pubmed/26964800 http://dx.doi.org/10.1007/s10103-016-1914-y Text en © The Author(s) 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Review Article
Hadis, Mohammed A.
Zainal, Siti A.
Holder, Michelle J.
Carroll, James D.
Cooper, Paul R.
Milward, Michael R.
Palin, William M.
The dark art of light measurement: accurate radiometry for low-level light therapy
title The dark art of light measurement: accurate radiometry for low-level light therapy
title_full The dark art of light measurement: accurate radiometry for low-level light therapy
title_fullStr The dark art of light measurement: accurate radiometry for low-level light therapy
title_full_unstemmed The dark art of light measurement: accurate radiometry for low-level light therapy
title_short The dark art of light measurement: accurate radiometry for low-level light therapy
title_sort dark art of light measurement: accurate radiometry for low-level light therapy
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4851696/
https://www.ncbi.nlm.nih.gov/pubmed/26964800
http://dx.doi.org/10.1007/s10103-016-1914-y
work_keys_str_mv AT hadismohammeda thedarkartoflightmeasurementaccurateradiometryforlowlevellighttherapy
AT zainalsitia thedarkartoflightmeasurementaccurateradiometryforlowlevellighttherapy
AT holdermichellej thedarkartoflightmeasurementaccurateradiometryforlowlevellighttherapy
AT carrolljamesd thedarkartoflightmeasurementaccurateradiometryforlowlevellighttherapy
AT cooperpaulr thedarkartoflightmeasurementaccurateradiometryforlowlevellighttherapy
AT milwardmichaelr thedarkartoflightmeasurementaccurateradiometryforlowlevellighttherapy
AT palinwilliamm thedarkartoflightmeasurementaccurateradiometryforlowlevellighttherapy
AT hadismohammeda darkartoflightmeasurementaccurateradiometryforlowlevellighttherapy
AT zainalsitia darkartoflightmeasurementaccurateradiometryforlowlevellighttherapy
AT holdermichellej darkartoflightmeasurementaccurateradiometryforlowlevellighttherapy
AT carrolljamesd darkartoflightmeasurementaccurateradiometryforlowlevellighttherapy
AT cooperpaulr darkartoflightmeasurementaccurateradiometryforlowlevellighttherapy
AT milwardmichaelr darkartoflightmeasurementaccurateradiometryforlowlevellighttherapy
AT palinwilliamm darkartoflightmeasurementaccurateradiometryforlowlevellighttherapy