Cargando…
The dark art of light measurement: accurate radiometry for low-level light therapy
Lasers and light-emitting diodes are used for a range of biomedical applications with many studies reporting their beneficial effects. However, three main concerns exist regarding much of the low-level light therapy (LLLT) or photobiomodulation literature; (1) incomplete, inaccurate and unverified i...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer London
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4851696/ https://www.ncbi.nlm.nih.gov/pubmed/26964800 http://dx.doi.org/10.1007/s10103-016-1914-y |
_version_ | 1782429846444441600 |
---|---|
author | Hadis, Mohammed A. Zainal, Siti A. Holder, Michelle J. Carroll, James D. Cooper, Paul R. Milward, Michael R. Palin, William M. |
author_facet | Hadis, Mohammed A. Zainal, Siti A. Holder, Michelle J. Carroll, James D. Cooper, Paul R. Milward, Michael R. Palin, William M. |
author_sort | Hadis, Mohammed A. |
collection | PubMed |
description | Lasers and light-emitting diodes are used for a range of biomedical applications with many studies reporting their beneficial effects. However, three main concerns exist regarding much of the low-level light therapy (LLLT) or photobiomodulation literature; (1) incomplete, inaccurate and unverified irradiation parameters, (2) miscalculation of ‘dose,’ and (3) the misuse of appropriate light property terminology. The aim of this systematic review was to assess where, and to what extent, these inadequacies exist and to provide an overview of ‘best practice’ in light measurement methods and importance of correct light measurement. A review of recent relevant literature was performed in PubMed using the terms LLLT and photobiomodulation (March 2014–March 2015) to investigate the contemporary information available in LLLT and photobiomodulation literature in terms of reporting light properties and irradiation parameters. A total of 74 articles formed the basis of this systematic review. Although most articles reported beneficial effects following LLLT, the majority contained no information in terms of how light was measured (73 %) and relied on manufacturer-stated values. For all papers reviewed, missing information for specific light parameters included wavelength (3 %), light source type (8 %), power (41 %), pulse frequency (52 %), beam area (40 %), irradiance (43 %), exposure time (16 %), radiant energy (74 %) and fluence (16 %). Frequent use of incorrect terminology was also observed within the reviewed literature. A poor understanding of photophysics is evident as a significant number of papers neglected to report or misreported important radiometric data. These errors affect repeatability and reliability of studies shared between scientists, manufacturers and clinicians and could degrade efficacy of patient treatments. Researchers need a physicist or appropriately skilled engineer on the team, and manuscript reviewers should reject papers that do not report beam measurement methods and all ten key parameters: wavelength, power, irradiation time, beam area (at the skin or culture surface; this is not necessarily the same size as the aperture), radiant energy, radiant exposure, pulse parameters, number of treatments, interval between treatments and anatomical location. Inclusion of these parameters will improve the information available to compare and contrast study outcomes and improve repeatability, reliability of studies. |
format | Online Article Text |
id | pubmed-4851696 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Springer London |
record_format | MEDLINE/PubMed |
spelling | pubmed-48516962016-05-19 The dark art of light measurement: accurate radiometry for low-level light therapy Hadis, Mohammed A. Zainal, Siti A. Holder, Michelle J. Carroll, James D. Cooper, Paul R. Milward, Michael R. Palin, William M. Lasers Med Sci Review Article Lasers and light-emitting diodes are used for a range of biomedical applications with many studies reporting their beneficial effects. However, three main concerns exist regarding much of the low-level light therapy (LLLT) or photobiomodulation literature; (1) incomplete, inaccurate and unverified irradiation parameters, (2) miscalculation of ‘dose,’ and (3) the misuse of appropriate light property terminology. The aim of this systematic review was to assess where, and to what extent, these inadequacies exist and to provide an overview of ‘best practice’ in light measurement methods and importance of correct light measurement. A review of recent relevant literature was performed in PubMed using the terms LLLT and photobiomodulation (March 2014–March 2015) to investigate the contemporary information available in LLLT and photobiomodulation literature in terms of reporting light properties and irradiation parameters. A total of 74 articles formed the basis of this systematic review. Although most articles reported beneficial effects following LLLT, the majority contained no information in terms of how light was measured (73 %) and relied on manufacturer-stated values. For all papers reviewed, missing information for specific light parameters included wavelength (3 %), light source type (8 %), power (41 %), pulse frequency (52 %), beam area (40 %), irradiance (43 %), exposure time (16 %), radiant energy (74 %) and fluence (16 %). Frequent use of incorrect terminology was also observed within the reviewed literature. A poor understanding of photophysics is evident as a significant number of papers neglected to report or misreported important radiometric data. These errors affect repeatability and reliability of studies shared between scientists, manufacturers and clinicians and could degrade efficacy of patient treatments. Researchers need a physicist or appropriately skilled engineer on the team, and manuscript reviewers should reject papers that do not report beam measurement methods and all ten key parameters: wavelength, power, irradiation time, beam area (at the skin or culture surface; this is not necessarily the same size as the aperture), radiant energy, radiant exposure, pulse parameters, number of treatments, interval between treatments and anatomical location. Inclusion of these parameters will improve the information available to compare and contrast study outcomes and improve repeatability, reliability of studies. Springer London 2016-03-10 2016 /pmc/articles/PMC4851696/ /pubmed/26964800 http://dx.doi.org/10.1007/s10103-016-1914-y Text en © The Author(s) 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Review Article Hadis, Mohammed A. Zainal, Siti A. Holder, Michelle J. Carroll, James D. Cooper, Paul R. Milward, Michael R. Palin, William M. The dark art of light measurement: accurate radiometry for low-level light therapy |
title | The dark art of light measurement: accurate radiometry for low-level light therapy |
title_full | The dark art of light measurement: accurate radiometry for low-level light therapy |
title_fullStr | The dark art of light measurement: accurate radiometry for low-level light therapy |
title_full_unstemmed | The dark art of light measurement: accurate radiometry for low-level light therapy |
title_short | The dark art of light measurement: accurate radiometry for low-level light therapy |
title_sort | dark art of light measurement: accurate radiometry for low-level light therapy |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4851696/ https://www.ncbi.nlm.nih.gov/pubmed/26964800 http://dx.doi.org/10.1007/s10103-016-1914-y |
work_keys_str_mv | AT hadismohammeda thedarkartoflightmeasurementaccurateradiometryforlowlevellighttherapy AT zainalsitia thedarkartoflightmeasurementaccurateradiometryforlowlevellighttherapy AT holdermichellej thedarkartoflightmeasurementaccurateradiometryforlowlevellighttherapy AT carrolljamesd thedarkartoflightmeasurementaccurateradiometryforlowlevellighttherapy AT cooperpaulr thedarkartoflightmeasurementaccurateradiometryforlowlevellighttherapy AT milwardmichaelr thedarkartoflightmeasurementaccurateradiometryforlowlevellighttherapy AT palinwilliamm thedarkartoflightmeasurementaccurateradiometryforlowlevellighttherapy AT hadismohammeda darkartoflightmeasurementaccurateradiometryforlowlevellighttherapy AT zainalsitia darkartoflightmeasurementaccurateradiometryforlowlevellighttherapy AT holdermichellej darkartoflightmeasurementaccurateradiometryforlowlevellighttherapy AT carrolljamesd darkartoflightmeasurementaccurateradiometryforlowlevellighttherapy AT cooperpaulr darkartoflightmeasurementaccurateradiometryforlowlevellighttherapy AT milwardmichaelr darkartoflightmeasurementaccurateradiometryforlowlevellighttherapy AT palinwilliamm darkartoflightmeasurementaccurateradiometryforlowlevellighttherapy |