Estimation Based on Emission Wavelength of Dabigatran Etexilate Mesylate in Bulk and Capsule Dosage Form

A simple, rapid, specific and highly sensitive spectrofluorimetric method has been developed for the quantification of dabigatran etexilate mesylate in bulk and capsule dosage form. A linear relationship was found between fluorescence intensity and concentration in the range of 0.01-1.0 μg/ml in dim...

Descripción completa

Detalles Bibliográficos
Autores principales: Anumolu, P. D., Satyanarayana, M., Gayatri, T., Praveena, M., Sunitha, G., Subrahmanyam, C.V.S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4852568/
https://www.ncbi.nlm.nih.gov/pubmed/27168697
_version_ 1782429958334840832
author Anumolu, P. D.
Satyanarayana, M.
Gayatri, T.
Praveena, M.
Sunitha, G.
Subrahmanyam, C.V.S.
author_facet Anumolu, P. D.
Satyanarayana, M.
Gayatri, T.
Praveena, M.
Sunitha, G.
Subrahmanyam, C.V.S.
author_sort Anumolu, P. D.
collection PubMed
description A simple, rapid, specific and highly sensitive spectrofluorimetric method has been developed for the quantification of dabigatran etexilate mesylate in bulk and capsule dosage form. A linear relationship was found between fluorescence intensity and concentration in the range of 0.01-1.0 μg/ml in dimethyl sulphoxide as solvent at an emission wavelength of 391 nm after excitation at 334 nm, with a good correlation coefficient (0.989). The detection and quantification limits were found to be 0.005 and 0.015 μg/ml, respectively. The proposed method was applied for dabigatran etexilate mesylate capsules, results reveal with percentage recovery of 102% and percentage relative standard deviation values were found to be less than 2 for accuracy and precision studies. The proposed method was validated for linearity, range, accuracy, precision, limit of detection and quantification according to International Conference on Harmonization guidelines. Statistical analysis of the results revealed high accuracy and good precision. The suggested procedures could be used for the determination of dabigatran etexilate mesylate in bulk and capsule dosage form in quality control laboratories of industries as well as in academic institutions.
format Online
Article
Text
id pubmed-4852568
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-48525682016-05-10 Estimation Based on Emission Wavelength of Dabigatran Etexilate Mesylate in Bulk and Capsule Dosage Form Anumolu, P. D. Satyanarayana, M. Gayatri, T. Praveena, M. Sunitha, G. Subrahmanyam, C.V.S. Indian J Pharm Sci Short Communication A simple, rapid, specific and highly sensitive spectrofluorimetric method has been developed for the quantification of dabigatran etexilate mesylate in bulk and capsule dosage form. A linear relationship was found between fluorescence intensity and concentration in the range of 0.01-1.0 μg/ml in dimethyl sulphoxide as solvent at an emission wavelength of 391 nm after excitation at 334 nm, with a good correlation coefficient (0.989). The detection and quantification limits were found to be 0.005 and 0.015 μg/ml, respectively. The proposed method was applied for dabigatran etexilate mesylate capsules, results reveal with percentage recovery of 102% and percentage relative standard deviation values were found to be less than 2 for accuracy and precision studies. The proposed method was validated for linearity, range, accuracy, precision, limit of detection and quantification according to International Conference on Harmonization guidelines. Statistical analysis of the results revealed high accuracy and good precision. The suggested procedures could be used for the determination of dabigatran etexilate mesylate in bulk and capsule dosage form in quality control laboratories of industries as well as in academic institutions. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC4852568/ /pubmed/27168697 Text en Copyright: © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution NonCommercial ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Short Communication
Anumolu, P. D.
Satyanarayana, M.
Gayatri, T.
Praveena, M.
Sunitha, G.
Subrahmanyam, C.V.S.
Estimation Based on Emission Wavelength of Dabigatran Etexilate Mesylate in Bulk and Capsule Dosage Form
title Estimation Based on Emission Wavelength of Dabigatran Etexilate Mesylate in Bulk and Capsule Dosage Form
title_full Estimation Based on Emission Wavelength of Dabigatran Etexilate Mesylate in Bulk and Capsule Dosage Form
title_fullStr Estimation Based on Emission Wavelength of Dabigatran Etexilate Mesylate in Bulk and Capsule Dosage Form
title_full_unstemmed Estimation Based on Emission Wavelength of Dabigatran Etexilate Mesylate in Bulk and Capsule Dosage Form
title_short Estimation Based on Emission Wavelength of Dabigatran Etexilate Mesylate in Bulk and Capsule Dosage Form
title_sort estimation based on emission wavelength of dabigatran etexilate mesylate in bulk and capsule dosage form
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4852568/
https://www.ncbi.nlm.nih.gov/pubmed/27168697
work_keys_str_mv AT anumolupd estimationbasedonemissionwavelengthofdabigatranetexilatemesylateinbulkandcapsuledosageform
AT satyanarayanam estimationbasedonemissionwavelengthofdabigatranetexilatemesylateinbulkandcapsuledosageform
AT gayatrit estimationbasedonemissionwavelengthofdabigatranetexilatemesylateinbulkandcapsuledosageform
AT praveenam estimationbasedonemissionwavelengthofdabigatranetexilatemesylateinbulkandcapsuledosageform
AT sunithag estimationbasedonemissionwavelengthofdabigatranetexilatemesylateinbulkandcapsuledosageform
AT subrahmanyamcvs estimationbasedonemissionwavelengthofdabigatranetexilatemesylateinbulkandcapsuledosageform