Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study

OBJECTIVES: Hips with metal-on-metal total hip arthroplasty (MoM THA) have a high rate of adverse local tissue reactions (ALTR), often associated with hypersensitivity reactions. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures tissue perfusion with the parameter Ktrans (volum...

Descripción completa

Detalles Bibliográficos
Autores principales: Anwander, H., Cron, G. O., Rakhra, K., Beaule, P. E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4852810/
https://www.ncbi.nlm.nih.gov/pubmed/26935768
http://dx.doi.org/10.1302/2046-3758.53.2000572
_version_ 1782429993272344576
author Anwander, H.
Cron, G. O.
Rakhra, K.
Beaule, P. E.
author_facet Anwander, H.
Cron, G. O.
Rakhra, K.
Beaule, P. E.
author_sort Anwander, H.
collection PubMed
description OBJECTIVES: Hips with metal-on-metal total hip arthroplasty (MoM THA) have a high rate of adverse local tissue reactions (ALTR), often associated with hypersensitivity reactions. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures tissue perfusion with the parameter Ktrans (volume transfer constant of contrast agent). Our purpose was 1) to evaluate the feasibility of DCE-MRI in patients with THA and 2) to compare DCE-MRI in patients with MoM bearings with metal-on-polyethylene (MoP) bearings, hypothesising that the perfusion index Ktrans in hips with MoM THA is higher than in hips with MoP THA. METHODS: In this pilot study, 16 patients with primary THA were recruited (eight MoM, eight MoP). DCE-MRI of the hip was performed at 1.5 Tesla (T). For each patient, Ktrans was computed voxel-by-voxel in all tissue lateral to the bladder. The mean Ktrans for all voxels was then calculated. These values were compared with respect to implant type and gender, and further correlated with clinical parameters. RESULTS: There was no significant difference between the two bearing types with both genders combined. However, dividing patients by THA bearing and gender, women with MoM bearings had the highest Ktrans values, exceeding those of women with MoP bearings (0.067 min(−1) versus 0.053 min(−1); p-value < 0.05) and men with MoM bearings (0.067 min(−1) versus 0.034 min(−1); p-value < 0.001). Considering only the men, patients with MoM bearings had lower Ktrans than those with MoP bearings (0.034 min(−1) versus 0.046 min(−1); p < 0.05). CONCLUSION: DCE-MRI is feasible to perform in tissues surrounding THA. Females with MoM THA show high Ktrans values in DCE-MRI, suggesting altered tissue perfusion kinematics which may reflect relatively greater inflammation. Cite this article: Dr P. E. Beaule. Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot stud. Bone Joint Res 2016;5:73–79. DOI: 10.1302/2046-3758.53.2000572.
format Online
Article
Text
id pubmed-4852810
institution National Center for Biotechnology Information
language English
publishDate 2016
record_format MEDLINE/PubMed
spelling pubmed-48528102016-05-11 Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study Anwander, H. Cron, G. O. Rakhra, K. Beaule, P. E. Bone Joint Res Arthroplasty OBJECTIVES: Hips with metal-on-metal total hip arthroplasty (MoM THA) have a high rate of adverse local tissue reactions (ALTR), often associated with hypersensitivity reactions. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures tissue perfusion with the parameter Ktrans (volume transfer constant of contrast agent). Our purpose was 1) to evaluate the feasibility of DCE-MRI in patients with THA and 2) to compare DCE-MRI in patients with MoM bearings with metal-on-polyethylene (MoP) bearings, hypothesising that the perfusion index Ktrans in hips with MoM THA is higher than in hips with MoP THA. METHODS: In this pilot study, 16 patients with primary THA were recruited (eight MoM, eight MoP). DCE-MRI of the hip was performed at 1.5 Tesla (T). For each patient, Ktrans was computed voxel-by-voxel in all tissue lateral to the bladder. The mean Ktrans for all voxels was then calculated. These values were compared with respect to implant type and gender, and further correlated with clinical parameters. RESULTS: There was no significant difference between the two bearing types with both genders combined. However, dividing patients by THA bearing and gender, women with MoM bearings had the highest Ktrans values, exceeding those of women with MoP bearings (0.067 min(−1) versus 0.053 min(−1); p-value < 0.05) and men with MoM bearings (0.067 min(−1) versus 0.034 min(−1); p-value < 0.001). Considering only the men, patients with MoM bearings had lower Ktrans than those with MoP bearings (0.034 min(−1) versus 0.046 min(−1); p < 0.05). CONCLUSION: DCE-MRI is feasible to perform in tissues surrounding THA. Females with MoM THA show high Ktrans values in DCE-MRI, suggesting altered tissue perfusion kinematics which may reflect relatively greater inflammation. Cite this article: Dr P. E. Beaule. Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot stud. Bone Joint Res 2016;5:73–79. DOI: 10.1302/2046-3758.53.2000572. 2016-04-08 /pmc/articles/PMC4852810/ /pubmed/26935768 http://dx.doi.org/10.1302/2046-3758.53.2000572 Text en © 2016 Beaule et al. This is an open-access article distributed under the terms of the Creative Commons Attributions licence (CC -BY-NC), which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited.
spellingShingle Arthroplasty
Anwander, H.
Cron, G. O.
Rakhra, K.
Beaule, P. E.
Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study
title Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study
title_full Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study
title_fullStr Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study
title_full_unstemmed Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study
title_short Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study
title_sort perfusion mri in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: a pilot study
topic Arthroplasty
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4852810/
https://www.ncbi.nlm.nih.gov/pubmed/26935768
http://dx.doi.org/10.1302/2046-3758.53.2000572
work_keys_str_mv AT anwanderh perfusionmriinhipswithmetalonmetalandmetalonpolyethylenetotalhiparthroplastyapilotstudy
AT crongo perfusionmriinhipswithmetalonmetalandmetalonpolyethylenetotalhiparthroplastyapilotstudy
AT rakhrak perfusionmriinhipswithmetalonmetalandmetalonpolyethylenetotalhiparthroplastyapilotstudy
AT beaulepe perfusionmriinhipswithmetalonmetalandmetalonpolyethylenetotalhiparthroplastyapilotstudy