Cargando…
Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study
OBJECTIVES: Hips with metal-on-metal total hip arthroplasty (MoM THA) have a high rate of adverse local tissue reactions (ALTR), often associated with hypersensitivity reactions. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures tissue perfusion with the parameter Ktrans (volum...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4852810/ https://www.ncbi.nlm.nih.gov/pubmed/26935768 http://dx.doi.org/10.1302/2046-3758.53.2000572 |
_version_ | 1782429993272344576 |
---|---|
author | Anwander, H. Cron, G. O. Rakhra, K. Beaule, P. E. |
author_facet | Anwander, H. Cron, G. O. Rakhra, K. Beaule, P. E. |
author_sort | Anwander, H. |
collection | PubMed |
description | OBJECTIVES: Hips with metal-on-metal total hip arthroplasty (MoM THA) have a high rate of adverse local tissue reactions (ALTR), often associated with hypersensitivity reactions. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures tissue perfusion with the parameter Ktrans (volume transfer constant of contrast agent). Our purpose was 1) to evaluate the feasibility of DCE-MRI in patients with THA and 2) to compare DCE-MRI in patients with MoM bearings with metal-on-polyethylene (MoP) bearings, hypothesising that the perfusion index Ktrans in hips with MoM THA is higher than in hips with MoP THA. METHODS: In this pilot study, 16 patients with primary THA were recruited (eight MoM, eight MoP). DCE-MRI of the hip was performed at 1.5 Tesla (T). For each patient, Ktrans was computed voxel-by-voxel in all tissue lateral to the bladder. The mean Ktrans for all voxels was then calculated. These values were compared with respect to implant type and gender, and further correlated with clinical parameters. RESULTS: There was no significant difference between the two bearing types with both genders combined. However, dividing patients by THA bearing and gender, women with MoM bearings had the highest Ktrans values, exceeding those of women with MoP bearings (0.067 min(−1) versus 0.053 min(−1); p-value < 0.05) and men with MoM bearings (0.067 min(−1) versus 0.034 min(−1); p-value < 0.001). Considering only the men, patients with MoM bearings had lower Ktrans than those with MoP bearings (0.034 min(−1) versus 0.046 min(−1); p < 0.05). CONCLUSION: DCE-MRI is feasible to perform in tissues surrounding THA. Females with MoM THA show high Ktrans values in DCE-MRI, suggesting altered tissue perfusion kinematics which may reflect relatively greater inflammation. Cite this article: Dr P. E. Beaule. Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot stud. Bone Joint Res 2016;5:73–79. DOI: 10.1302/2046-3758.53.2000572. |
format | Online Article Text |
id | pubmed-4852810 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
record_format | MEDLINE/PubMed |
spelling | pubmed-48528102016-05-11 Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study Anwander, H. Cron, G. O. Rakhra, K. Beaule, P. E. Bone Joint Res Arthroplasty OBJECTIVES: Hips with metal-on-metal total hip arthroplasty (MoM THA) have a high rate of adverse local tissue reactions (ALTR), often associated with hypersensitivity reactions. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures tissue perfusion with the parameter Ktrans (volume transfer constant of contrast agent). Our purpose was 1) to evaluate the feasibility of DCE-MRI in patients with THA and 2) to compare DCE-MRI in patients with MoM bearings with metal-on-polyethylene (MoP) bearings, hypothesising that the perfusion index Ktrans in hips with MoM THA is higher than in hips with MoP THA. METHODS: In this pilot study, 16 patients with primary THA were recruited (eight MoM, eight MoP). DCE-MRI of the hip was performed at 1.5 Tesla (T). For each patient, Ktrans was computed voxel-by-voxel in all tissue lateral to the bladder. The mean Ktrans for all voxels was then calculated. These values were compared with respect to implant type and gender, and further correlated with clinical parameters. RESULTS: There was no significant difference between the two bearing types with both genders combined. However, dividing patients by THA bearing and gender, women with MoM bearings had the highest Ktrans values, exceeding those of women with MoP bearings (0.067 min(−1) versus 0.053 min(−1); p-value < 0.05) and men with MoM bearings (0.067 min(−1) versus 0.034 min(−1); p-value < 0.001). Considering only the men, patients with MoM bearings had lower Ktrans than those with MoP bearings (0.034 min(−1) versus 0.046 min(−1); p < 0.05). CONCLUSION: DCE-MRI is feasible to perform in tissues surrounding THA. Females with MoM THA show high Ktrans values in DCE-MRI, suggesting altered tissue perfusion kinematics which may reflect relatively greater inflammation. Cite this article: Dr P. E. Beaule. Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot stud. Bone Joint Res 2016;5:73–79. DOI: 10.1302/2046-3758.53.2000572. 2016-04-08 /pmc/articles/PMC4852810/ /pubmed/26935768 http://dx.doi.org/10.1302/2046-3758.53.2000572 Text en © 2016 Beaule et al. This is an open-access article distributed under the terms of the Creative Commons Attributions licence (CC -BY-NC), which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited. |
spellingShingle | Arthroplasty Anwander, H. Cron, G. O. Rakhra, K. Beaule, P. E. Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study |
title | Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study |
title_full | Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study |
title_fullStr | Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study |
title_full_unstemmed | Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study |
title_short | Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study |
title_sort | perfusion mri in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: a pilot study |
topic | Arthroplasty |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4852810/ https://www.ncbi.nlm.nih.gov/pubmed/26935768 http://dx.doi.org/10.1302/2046-3758.53.2000572 |
work_keys_str_mv | AT anwanderh perfusionmriinhipswithmetalonmetalandmetalonpolyethylenetotalhiparthroplastyapilotstudy AT crongo perfusionmriinhipswithmetalonmetalandmetalonpolyethylenetotalhiparthroplastyapilotstudy AT rakhrak perfusionmriinhipswithmetalonmetalandmetalonpolyethylenetotalhiparthroplastyapilotstudy AT beaulepe perfusionmriinhipswithmetalonmetalandmetalonpolyethylenetotalhiparthroplastyapilotstudy |