Cargando…

Quality Control of Motor Unit Number Index (MUNIX) Measurements in 6 Muscles in a Single-Subject “Round-Robin” Setup

BACKGROUND: Motor Unit Number Index (MUNIX) is a neurophysiological measure that provides an index of the number of lower motor neurons in a muscle. Its performance across centres in healthy subjects and patients with Amyotrophic Lateral Sclerosis (ALS) has been established, but inter-rater variabil...

Descripción completa

Detalles Bibliográficos
Autores principales: Neuwirth, Christoph, Burkhardt, Christian, Alix, James, Castro, José, de Carvalho, Mamede, Gawel, Malgorzata, Goedee, Stephan, Grosskreutz, Julian, Lenglet, Timothée, Moglia, Cristina, Omer, Taha, Schrooten, Maarten, Weber, Markus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4852906/
https://www.ncbi.nlm.nih.gov/pubmed/27135747
http://dx.doi.org/10.1371/journal.pone.0153948
_version_ 1782430005574238208
author Neuwirth, Christoph
Burkhardt, Christian
Alix, James
Castro, José
de Carvalho, Mamede
Gawel, Malgorzata
Goedee, Stephan
Grosskreutz, Julian
Lenglet, Timothée
Moglia, Cristina
Omer, Taha
Schrooten, Maarten
Weber, Markus
author_facet Neuwirth, Christoph
Burkhardt, Christian
Alix, James
Castro, José
de Carvalho, Mamede
Gawel, Malgorzata
Goedee, Stephan
Grosskreutz, Julian
Lenglet, Timothée
Moglia, Cristina
Omer, Taha
Schrooten, Maarten
Weber, Markus
author_sort Neuwirth, Christoph
collection PubMed
description BACKGROUND: Motor Unit Number Index (MUNIX) is a neurophysiological measure that provides an index of the number of lower motor neurons in a muscle. Its performance across centres in healthy subjects and patients with Amyotrophic Lateral Sclerosis (ALS) has been established, but inter-rater variability between multiple raters in one single subject has not been investigated. OBJECTIVE: To assess reliability in a set of 6 muscles in a single subject among 12 examiners (6 experienced with MUNIX, 6 less experienced) and to determine variables associated with variability of measurements. METHODS: Twelve raters applied MUNIX in six different muscles (abductor pollicis brevis (APB), abductor digiti minimi (ADM), biceps brachii (BB), tibialis anterior (TA), extensor dig. brevis (EDB), abductor hallucis (AH)) twice in one single volunteer on consecutive days. All raters visited at least one training course prior to measurements. Intra- and inter-rater variability as determined by the coefficient of variation (COV) between different raters and their levels of experience with MUNIX were compared. RESULTS: Mean intra-rater COV of MUNIX was 14.0% (±6.4) ranging from 5.8 (APB) to 30.3% (EDB). Mean inter-rater COV was 18.1 (±5.4) ranging from 8.0 (BB) to 31.7 (AH). No significant differences of variability between experienced and less experienced raters were detected. CONCLUSION: We provide evidence that quality control for neurophysiological methods can be performed with similar standards as in laboratory medicine. Intra- and inter-rater variability of MUNIX is muscle-dependent and mainly below 20%. Experienced neurophysiologists can easily adopt MUNIX and adequate teaching ensures reliable utilization of this method.
format Online
Article
Text
id pubmed-4852906
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-48529062016-05-13 Quality Control of Motor Unit Number Index (MUNIX) Measurements in 6 Muscles in a Single-Subject “Round-Robin” Setup Neuwirth, Christoph Burkhardt, Christian Alix, James Castro, José de Carvalho, Mamede Gawel, Malgorzata Goedee, Stephan Grosskreutz, Julian Lenglet, Timothée Moglia, Cristina Omer, Taha Schrooten, Maarten Weber, Markus PLoS One Research Article BACKGROUND: Motor Unit Number Index (MUNIX) is a neurophysiological measure that provides an index of the number of lower motor neurons in a muscle. Its performance across centres in healthy subjects and patients with Amyotrophic Lateral Sclerosis (ALS) has been established, but inter-rater variability between multiple raters in one single subject has not been investigated. OBJECTIVE: To assess reliability in a set of 6 muscles in a single subject among 12 examiners (6 experienced with MUNIX, 6 less experienced) and to determine variables associated with variability of measurements. METHODS: Twelve raters applied MUNIX in six different muscles (abductor pollicis brevis (APB), abductor digiti minimi (ADM), biceps brachii (BB), tibialis anterior (TA), extensor dig. brevis (EDB), abductor hallucis (AH)) twice in one single volunteer on consecutive days. All raters visited at least one training course prior to measurements. Intra- and inter-rater variability as determined by the coefficient of variation (COV) between different raters and their levels of experience with MUNIX were compared. RESULTS: Mean intra-rater COV of MUNIX was 14.0% (±6.4) ranging from 5.8 (APB) to 30.3% (EDB). Mean inter-rater COV was 18.1 (±5.4) ranging from 8.0 (BB) to 31.7 (AH). No significant differences of variability between experienced and less experienced raters were detected. CONCLUSION: We provide evidence that quality control for neurophysiological methods can be performed with similar standards as in laboratory medicine. Intra- and inter-rater variability of MUNIX is muscle-dependent and mainly below 20%. Experienced neurophysiologists can easily adopt MUNIX and adequate teaching ensures reliable utilization of this method. Public Library of Science 2016-05-02 /pmc/articles/PMC4852906/ /pubmed/27135747 http://dx.doi.org/10.1371/journal.pone.0153948 Text en © 2016 Neuwirth et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Neuwirth, Christoph
Burkhardt, Christian
Alix, James
Castro, José
de Carvalho, Mamede
Gawel, Malgorzata
Goedee, Stephan
Grosskreutz, Julian
Lenglet, Timothée
Moglia, Cristina
Omer, Taha
Schrooten, Maarten
Weber, Markus
Quality Control of Motor Unit Number Index (MUNIX) Measurements in 6 Muscles in a Single-Subject “Round-Robin” Setup
title Quality Control of Motor Unit Number Index (MUNIX) Measurements in 6 Muscles in a Single-Subject “Round-Robin” Setup
title_full Quality Control of Motor Unit Number Index (MUNIX) Measurements in 6 Muscles in a Single-Subject “Round-Robin” Setup
title_fullStr Quality Control of Motor Unit Number Index (MUNIX) Measurements in 6 Muscles in a Single-Subject “Round-Robin” Setup
title_full_unstemmed Quality Control of Motor Unit Number Index (MUNIX) Measurements in 6 Muscles in a Single-Subject “Round-Robin” Setup
title_short Quality Control of Motor Unit Number Index (MUNIX) Measurements in 6 Muscles in a Single-Subject “Round-Robin” Setup
title_sort quality control of motor unit number index (munix) measurements in 6 muscles in a single-subject “round-robin” setup
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4852906/
https://www.ncbi.nlm.nih.gov/pubmed/27135747
http://dx.doi.org/10.1371/journal.pone.0153948
work_keys_str_mv AT neuwirthchristoph qualitycontrolofmotorunitnumberindexmunixmeasurementsin6musclesinasinglesubjectroundrobinsetup
AT burkhardtchristian qualitycontrolofmotorunitnumberindexmunixmeasurementsin6musclesinasinglesubjectroundrobinsetup
AT alixjames qualitycontrolofmotorunitnumberindexmunixmeasurementsin6musclesinasinglesubjectroundrobinsetup
AT castrojose qualitycontrolofmotorunitnumberindexmunixmeasurementsin6musclesinasinglesubjectroundrobinsetup
AT decarvalhomamede qualitycontrolofmotorunitnumberindexmunixmeasurementsin6musclesinasinglesubjectroundrobinsetup
AT gawelmalgorzata qualitycontrolofmotorunitnumberindexmunixmeasurementsin6musclesinasinglesubjectroundrobinsetup
AT goedeestephan qualitycontrolofmotorunitnumberindexmunixmeasurementsin6musclesinasinglesubjectroundrobinsetup
AT grosskreutzjulian qualitycontrolofmotorunitnumberindexmunixmeasurementsin6musclesinasinglesubjectroundrobinsetup
AT lenglettimothee qualitycontrolofmotorunitnumberindexmunixmeasurementsin6musclesinasinglesubjectroundrobinsetup
AT mogliacristina qualitycontrolofmotorunitnumberindexmunixmeasurementsin6musclesinasinglesubjectroundrobinsetup
AT omertaha qualitycontrolofmotorunitnumberindexmunixmeasurementsin6musclesinasinglesubjectroundrobinsetup
AT schrootenmaarten qualitycontrolofmotorunitnumberindexmunixmeasurementsin6musclesinasinglesubjectroundrobinsetup
AT webermarkus qualitycontrolofmotorunitnumberindexmunixmeasurementsin6musclesinasinglesubjectroundrobinsetup