Cargando…

Poor Performance of the Chlamydia Rapid Test Device for the Detection of Asymptomatic Infections in South African Men: A Pilot Study

Background. To the best of our knowledge, there have been no published reports on the diagnostic performance of the Chlamydia Rapid Test (CRT) Device for male urine samples. We evaluated the performance of the CRT Device when compared with that of the BD ProbeTec ET PCR Assay in a population of asym...

Descripción completa

Detalles Bibliográficos
Autores principales: Abbai-Shaik, N. S., Reddy, T., Govender, S., Ramjee, G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4853942/
https://www.ncbi.nlm.nih.gov/pubmed/27195171
http://dx.doi.org/10.1155/2016/8695146
_version_ 1782430148734222336
author Abbai-Shaik, N. S.
Reddy, T.
Govender, S.
Ramjee, G.
author_facet Abbai-Shaik, N. S.
Reddy, T.
Govender, S.
Ramjee, G.
author_sort Abbai-Shaik, N. S.
collection PubMed
description Background. To the best of our knowledge, there have been no published reports on the diagnostic performance of the Chlamydia Rapid Test (CRT) Device for male urine samples. We evaluated the performance of the CRT Device when compared with that of the BD ProbeTec ET PCR Assay in a population of asymptomatic men. Methods. The study enrolled 100 men between June and July 2015. From each consenting male, 20–30 mL of urine was collected. Sensitivity and specificity of the rapid test compared to PCR were calculated. All analysis was performed in STATA version 13. Results. All men had valid rapid and PCR test results. The test showed a low sensitivity against PCR (20%) (95% CI 3.7–6.2%); however, an excellent specificity was observed (100%) (one sided 97.5% CI: 96.0–100). Conclusions. This test was not found to be suitable as a screening tool for genital Chlamydia infections in men. Our findings emphasize the need for more sensitive POC tests to be developed since the current approach for the management of STIs in Africa is confounded by poor sensitivity and specificity resulting in many infected individuals not being treated.
format Online
Article
Text
id pubmed-4853942
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-48539422016-05-18 Poor Performance of the Chlamydia Rapid Test Device for the Detection of Asymptomatic Infections in South African Men: A Pilot Study Abbai-Shaik, N. S. Reddy, T. Govender, S. Ramjee, G. J Sex Transm Dis Research Article Background. To the best of our knowledge, there have been no published reports on the diagnostic performance of the Chlamydia Rapid Test (CRT) Device for male urine samples. We evaluated the performance of the CRT Device when compared with that of the BD ProbeTec ET PCR Assay in a population of asymptomatic men. Methods. The study enrolled 100 men between June and July 2015. From each consenting male, 20–30 mL of urine was collected. Sensitivity and specificity of the rapid test compared to PCR were calculated. All analysis was performed in STATA version 13. Results. All men had valid rapid and PCR test results. The test showed a low sensitivity against PCR (20%) (95% CI 3.7–6.2%); however, an excellent specificity was observed (100%) (one sided 97.5% CI: 96.0–100). Conclusions. This test was not found to be suitable as a screening tool for genital Chlamydia infections in men. Our findings emphasize the need for more sensitive POC tests to be developed since the current approach for the management of STIs in Africa is confounded by poor sensitivity and specificity resulting in many infected individuals not being treated. Hindawi Publishing Corporation 2016 2016-04-19 /pmc/articles/PMC4853942/ /pubmed/27195171 http://dx.doi.org/10.1155/2016/8695146 Text en Copyright © 2016 N. S. Abbai-Shaik et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Abbai-Shaik, N. S.
Reddy, T.
Govender, S.
Ramjee, G.
Poor Performance of the Chlamydia Rapid Test Device for the Detection of Asymptomatic Infections in South African Men: A Pilot Study
title Poor Performance of the Chlamydia Rapid Test Device for the Detection of Asymptomatic Infections in South African Men: A Pilot Study
title_full Poor Performance of the Chlamydia Rapid Test Device for the Detection of Asymptomatic Infections in South African Men: A Pilot Study
title_fullStr Poor Performance of the Chlamydia Rapid Test Device for the Detection of Asymptomatic Infections in South African Men: A Pilot Study
title_full_unstemmed Poor Performance of the Chlamydia Rapid Test Device for the Detection of Asymptomatic Infections in South African Men: A Pilot Study
title_short Poor Performance of the Chlamydia Rapid Test Device for the Detection of Asymptomatic Infections in South African Men: A Pilot Study
title_sort poor performance of the chlamydia rapid test device for the detection of asymptomatic infections in south african men: a pilot study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4853942/
https://www.ncbi.nlm.nih.gov/pubmed/27195171
http://dx.doi.org/10.1155/2016/8695146
work_keys_str_mv AT abbaishaikns poorperformanceofthechlamydiarapidtestdeviceforthedetectionofasymptomaticinfectionsinsouthafricanmenapilotstudy
AT reddyt poorperformanceofthechlamydiarapidtestdeviceforthedetectionofasymptomaticinfectionsinsouthafricanmenapilotstudy
AT govenders poorperformanceofthechlamydiarapidtestdeviceforthedetectionofasymptomaticinfectionsinsouthafricanmenapilotstudy
AT ramjeeg poorperformanceofthechlamydiarapidtestdeviceforthedetectionofasymptomaticinfectionsinsouthafricanmenapilotstudy