Cargando…

Atheroembolization and potential air embolization during aortic declamping in open repair of a pararenal aortic aneurysm: A case report

INTRODUCTION: When ischemic events ascribable to microembolization occur during open repair of proximal abdominal aortic aneurysms, a likely origin of atheroembolism is not always found. PRESENTATION OF CASE: A 78-year old man with enlargement of the entire aorta underwent open repair for a pararena...

Descripción completa

Detalles Bibliográficos
Autores principales: Dregelid, Einar Børre, Lilleng, Peer Kåre
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4855746/
https://www.ncbi.nlm.nih.gov/pubmed/27100956
http://dx.doi.org/10.1016/j.ijscr.2016.04.017
_version_ 1782430405035556864
author Dregelid, Einar Børre
Lilleng, Peer Kåre
author_facet Dregelid, Einar Børre
Lilleng, Peer Kåre
author_sort Dregelid, Einar Børre
collection PubMed
description INTRODUCTION: When ischemic events ascribable to microembolization occur during open repair of proximal abdominal aortic aneurysms, a likely origin of atheroembolism is not always found. PRESENTATION OF CASE: A 78-year old man with enlargement of the entire aorta underwent open repair for a pararenal abdominal aortic aneurysm using supraceliac aortic clamping for 20 min. Then the graft was clamped, the supraceliac clamp was removed, and the distal and right renal anastomoses were also completed. The patient was stable throughout the operation with only transient drop in blood pressure on reperfusion. Postoperatively the patient developed ischemia, attributable to microembolization, in legs, small intestine, gall bladder and kidneys. He underwent fasciotomy, small bowel and gall bladder resections. Intestinal absorptive function did not recover adequately and he died after 4 months. Microscopic examination of hundreds of intestinal, juxtaintestinal mesenteric, and gall bladder arteries showed a few ones containing cholesterol emboli. DISCUSSION: It is unsure whether a few occluded small arteries out of several hundred could have caused the ischemic injury alone. There had been only moderate backbleeding from aortic branches above the proximal anastomosis while it was sutured. Inadvertently, remaining air in the graft, aorta, and aortic branches may have been whipped into the pulsating blood, resulting in air microbubbles, when the aortic clamp was removed. CONCLUSION: Although both atheromatous particles and air microbubbles are well-known causes of iatrogenic microembolization, the importance of air microembolization in open repair of pararenal aortic aneurysms is not known and need to be studied.
format Online
Article
Text
id pubmed-4855746
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-48557462016-05-24 Atheroembolization and potential air embolization during aortic declamping in open repair of a pararenal aortic aneurysm: A case report Dregelid, Einar Børre Lilleng, Peer Kåre Int J Surg Case Rep Case Report INTRODUCTION: When ischemic events ascribable to microembolization occur during open repair of proximal abdominal aortic aneurysms, a likely origin of atheroembolism is not always found. PRESENTATION OF CASE: A 78-year old man with enlargement of the entire aorta underwent open repair for a pararenal abdominal aortic aneurysm using supraceliac aortic clamping for 20 min. Then the graft was clamped, the supraceliac clamp was removed, and the distal and right renal anastomoses were also completed. The patient was stable throughout the operation with only transient drop in blood pressure on reperfusion. Postoperatively the patient developed ischemia, attributable to microembolization, in legs, small intestine, gall bladder and kidneys. He underwent fasciotomy, small bowel and gall bladder resections. Intestinal absorptive function did not recover adequately and he died after 4 months. Microscopic examination of hundreds of intestinal, juxtaintestinal mesenteric, and gall bladder arteries showed a few ones containing cholesterol emboli. DISCUSSION: It is unsure whether a few occluded small arteries out of several hundred could have caused the ischemic injury alone. There had been only moderate backbleeding from aortic branches above the proximal anastomosis while it was sutured. Inadvertently, remaining air in the graft, aorta, and aortic branches may have been whipped into the pulsating blood, resulting in air microbubbles, when the aortic clamp was removed. CONCLUSION: Although both atheromatous particles and air microbubbles are well-known causes of iatrogenic microembolization, the importance of air microembolization in open repair of pararenal aortic aneurysms is not known and need to be studied. Elsevier 2016-04-13 /pmc/articles/PMC4855746/ /pubmed/27100956 http://dx.doi.org/10.1016/j.ijscr.2016.04.017 Text en © 2016 Published by Elsevier Ltd. on behalf of IJS Publishing Group Ltd. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Dregelid, Einar Børre
Lilleng, Peer Kåre
Atheroembolization and potential air embolization during aortic declamping in open repair of a pararenal aortic aneurysm: A case report
title Atheroembolization and potential air embolization during aortic declamping in open repair of a pararenal aortic aneurysm: A case report
title_full Atheroembolization and potential air embolization during aortic declamping in open repair of a pararenal aortic aneurysm: A case report
title_fullStr Atheroembolization and potential air embolization during aortic declamping in open repair of a pararenal aortic aneurysm: A case report
title_full_unstemmed Atheroembolization and potential air embolization during aortic declamping in open repair of a pararenal aortic aneurysm: A case report
title_short Atheroembolization and potential air embolization during aortic declamping in open repair of a pararenal aortic aneurysm: A case report
title_sort atheroembolization and potential air embolization during aortic declamping in open repair of a pararenal aortic aneurysm: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4855746/
https://www.ncbi.nlm.nih.gov/pubmed/27100956
http://dx.doi.org/10.1016/j.ijscr.2016.04.017
work_keys_str_mv AT dregelideinarbørre atheroembolizationandpotentialairembolizationduringaorticdeclampinginopenrepairofapararenalaorticaneurysmacasereport
AT lillengpeerkare atheroembolizationandpotentialairembolizationduringaorticdeclampinginopenrepairofapararenalaorticaneurysmacasereport