Cargando…

Multiple endovascular aortic aneurysm repair graft failures and re-interventions over 15 years

Re-intervention on abdominal aortic aneurysm treated by endovascular aortic aneurysm repair for complications such as endoleak, graft migration, and graft failure is relatively common. However, re-do endovascular aortic aneurysm repair can be complex, as the failed graft still resides within the ves...

Descripción completa

Detalles Bibliográficos
Autores principales: Belchos, Jessica, Wheatcroft, Mark, Moloney, Tony
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4857307/
https://www.ncbi.nlm.nih.gov/pubmed/27489701
http://dx.doi.org/10.1177/2050313X15608558
Descripción
Sumario:Re-intervention on abdominal aortic aneurysm treated by endovascular aortic aneurysm repair for complications such as endoleak, graft migration, and graft failure is relatively common. However, re-do endovascular aortic aneurysm repair can be complex, as the failed graft still resides within the vessel. In addition, some re-do endovascular aortic aneurysm repairs call for an advanced custom graft, which can further increase the complexity and technical skill required. We describe a case of a 15-year-old endovascular aortic aneurysm repair originally implanted in a 71-year-old man, followed by three separate complications requiring intervention. We describe important procedural decisions taken into consideration when presented with failure of an older graft.