PURPOSE: Approximately 83 % of patients with bladder cancer have achieved a complete response after undergoing a novel bladder preservation therapy involving balloon-occluded intra-arterial infusion chemotherapy (BOAI) using a four-lumen double-balloon catheter, known as the Osaka Medical College re...

Descripción completa

Detalles Bibliográficos
Autores principales: Yamamoto, Kiyohito, Yamamoto, Kazuhiro, Nakai, Go, Azuma, Haruhito, Narumi, Yoshifumi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4858555/
https://www.ncbi.nlm.nih.gov/pubmed/26817759
http://dx.doi.org/10.1007/s00270-016-1296-3
_version_ 1782430821753290752
author Yamamoto, Kiyohito
Yamamoto, Kazuhiro
Nakai, Go
Azuma, Haruhito
Narumi, Yoshifumi
author_facet Yamamoto, Kiyohito
Yamamoto, Kazuhiro
Nakai, Go
Azuma, Haruhito
Narumi, Yoshifumi
author_sort Yamamoto, Kiyohito
collection PubMed
description PURPOSE: Approximately 83 % of patients with bladder cancer have achieved a complete response after undergoing a novel bladder preservation therapy involving balloon-occluded intra-arterial infusion chemotherapy (BOAI) using a four-lumen double-balloon catheter, known as the Osaka Medical College regimen. This study aimed to show the quantitative difference in hemodynamics of the bladder arteries using syngo iFlow (Siemens Healthcare, Erlangen, Germany), which provides an automatic tool for quantitative blood flow analysis between double BOAI (D-BOAI) and conventional single BOAI (S-BOAI). MATERIALS AND METHODS: Fifty patients were included. The catheters were introduced into both posterior trunks of the internal iliac arteries via contralateral femoral artery access. A side hole between the distal and proximal balloons was placed at the origin of each bladder artery to allow clear visualization of angiographic flow of the injected agent into the urinary bladder. Digital subtraction angiography was used during analysis with the syngo iFlow to evaluate the hemodynamics of the contrast medium in the pelvic arteries during BOAI. The comparative change in the amount of contrast medium in the bladder arteries between D-BOAI and S-BOAI was assessed using syngo iFlow. RESULTS: One-hundred pelvic sides were analyzed. The amount of contrast medium in the bladder arteries using D-BOAI was more than twice that using S-BOAI (right, 3.03-fold; left, 2.81-fold). CONCLUSION: The amount of contrast medium in the bladder arteries using D-BOAI was higher than that using conventional S-BOAI. This may increase the anticancer drug concentration in the affected bladder, leading to a good clinical response.
format Online
Article
Text
id pubmed-4858555
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-48585552016-05-21 Novel Software-Assisted Hemodynamic Evaluation of Pelvic Flow During Chemoperfusion of Pelvic Arteries for Bladder Cancer: Double- Versus Single-Balloon Technique Yamamoto, Kiyohito Yamamoto, Kazuhiro Nakai, Go Azuma, Haruhito Narumi, Yoshifumi Cardiovasc Intervent Radiol Clinical Investigation PURPOSE: Approximately 83 % of patients with bladder cancer have achieved a complete response after undergoing a novel bladder preservation therapy involving balloon-occluded intra-arterial infusion chemotherapy (BOAI) using a four-lumen double-balloon catheter, known as the Osaka Medical College regimen. This study aimed to show the quantitative difference in hemodynamics of the bladder arteries using syngo iFlow (Siemens Healthcare, Erlangen, Germany), which provides an automatic tool for quantitative blood flow analysis between double BOAI (D-BOAI) and conventional single BOAI (S-BOAI). MATERIALS AND METHODS: Fifty patients were included. The catheters were introduced into both posterior trunks of the internal iliac arteries via contralateral femoral artery access. A side hole between the distal and proximal balloons was placed at the origin of each bladder artery to allow clear visualization of angiographic flow of the injected agent into the urinary bladder. Digital subtraction angiography was used during analysis with the syngo iFlow to evaluate the hemodynamics of the contrast medium in the pelvic arteries during BOAI. The comparative change in the amount of contrast medium in the bladder arteries between D-BOAI and S-BOAI was assessed using syngo iFlow. RESULTS: One-hundred pelvic sides were analyzed. The amount of contrast medium in the bladder arteries using D-BOAI was more than twice that using S-BOAI (right, 3.03-fold; left, 2.81-fold). CONCLUSION: The amount of contrast medium in the bladder arteries using D-BOAI was higher than that using conventional S-BOAI. This may increase the anticancer drug concentration in the affected bladder, leading to a good clinical response. Springer US 2016-01-27 2016 /pmc/articles/PMC4858555/ /pubmed/26817759 http://dx.doi.org/10.1007/s00270-016-1296-3 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Clinical Investigation
Yamamoto, Kiyohito
Yamamoto, Kazuhiro
Nakai, Go
Azuma, Haruhito
Narumi, Yoshifumi
Novel Software-Assisted Hemodynamic Evaluation of Pelvic Flow During Chemoperfusion of Pelvic Arteries for Bladder Cancer: Double- Versus Single-Balloon Technique
title Novel Software-Assisted Hemodynamic Evaluation of Pelvic Flow During Chemoperfusion of Pelvic Arteries for Bladder Cancer: Double- Versus Single-Balloon Technique
title_full Novel Software-Assisted Hemodynamic Evaluation of Pelvic Flow During Chemoperfusion of Pelvic Arteries for Bladder Cancer: Double- Versus Single-Balloon Technique
title_fullStr Novel Software-Assisted Hemodynamic Evaluation of Pelvic Flow During Chemoperfusion of Pelvic Arteries for Bladder Cancer: Double- Versus Single-Balloon Technique
title_full_unstemmed Novel Software-Assisted Hemodynamic Evaluation of Pelvic Flow During Chemoperfusion of Pelvic Arteries for Bladder Cancer: Double- Versus Single-Balloon Technique
title_short Novel Software-Assisted Hemodynamic Evaluation of Pelvic Flow During Chemoperfusion of Pelvic Arteries for Bladder Cancer: Double- Versus Single-Balloon Technique
title_sort novel software-assisted hemodynamic evaluation of pelvic flow during chemoperfusion of pelvic arteries for bladder cancer: double- versus single-balloon technique
topic Clinical Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4858555/
https://www.ncbi.nlm.nih.gov/pubmed/26817759
http://dx.doi.org/10.1007/s00270-016-1296-3
work_keys_str_mv AT yamamotokiyohito novelsoftwareassistedhemodynamicevaluationofpelvicflowduringchemoperfusionofpelvicarteriesforbladdercancerdoubleversussingleballoontechnique
AT yamamotokazuhiro novelsoftwareassistedhemodynamicevaluationofpelvicflowduringchemoperfusionofpelvicarteriesforbladdercancerdoubleversussingleballoontechnique
AT nakaigo novelsoftwareassistedhemodynamicevaluationofpelvicflowduringchemoperfusionofpelvicarteriesforbladdercancerdoubleversussingleballoontechnique
AT azumaharuhito novelsoftwareassistedhemodynamicevaluationofpelvicflowduringchemoperfusionofpelvicarteriesforbladdercancerdoubleversussingleballoontechnique
AT narumiyoshifumi novelsoftwareassistedhemodynamicevaluationofpelvicflowduringchemoperfusionofpelvicarteriesforbladdercancerdoubleversussingleballoontechnique