Reproducibility of image-based computational models of intracranial aneurysm: a comparison between 3D rotational angiography, CT angiography and MR angiography

BACKGROUND: Reconstruction of patient-specific biomechanical model of intracranial aneurysm has been based on different imaging modalities. However, different imaging techniques may influence the model geometry and the computational fluid dynamics (CFD) simulation. The aim of this study is to evalua...

Descripción completa

Detalles Bibliográficos
Autores principales: Ren, Yuan, Chen, Guo-Zhong, Liu, Zhen, Cai, Yan, Lu, Guang-Ming, Li, Zhi-Yong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4858827/
https://www.ncbi.nlm.nih.gov/pubmed/27150439
http://dx.doi.org/10.1186/s12938-016-0163-4
_version_ 1782430862354153472
author Ren, Yuan
Chen, Guo-Zhong
Liu, Zhen
Cai, Yan
Lu, Guang-Ming
Li, Zhi-Yong
author_facet Ren, Yuan
Chen, Guo-Zhong
Liu, Zhen
Cai, Yan
Lu, Guang-Ming
Li, Zhi-Yong
author_sort Ren, Yuan
collection PubMed
description BACKGROUND: Reconstruction of patient-specific biomechanical model of intracranial aneurysm has been based on different imaging modalities. However, different imaging techniques may influence the model geometry and the computational fluid dynamics (CFD) simulation. The aim of this study is to evaluate the differences of the morphological and hemodynamic parameters in the computational models reconstructed from computed tomography angiography (CTA), magnetic resonance angiography (MRA) and 3D rotational angiography (3DRA). METHODS: Ten patients with cerebral aneurysms were enrolled in the study. MRA, CTA and 3DRA were performed on all patients. For each patient, three patient-specific models were reconstructed respectively based on the three sets of imaging data of the patient. CFD simulations were performed on each model. Model geometry and hemodynamic parameters were compared between the three models. RESULTS: In terms of morphological parameters, by comparing CTA based models (CM) and 3DRA based models (DM) which were treated as the “standard models”, the aspect ratio had the minimum difference (Δ = 8.3 ± 1.72 %, P = 0.953) and the surface distance was 0.25 ± 0.07 mm. Meanwhile, by comparing MRA based models (MM) and DM, the size had the minimum difference (Δ = 6.6 ± 1.85 %, P = 0.683) and the surface distance was 0.36 ± 0.1 mm. In respect of hemodynamic parameters, all three models showed a similar distribution: low average WSS at the sack, high OSI at the body and high average WSSG at the neck. However, there was a large variation in the average WSS (Δ = 34 ± 5.13 % for CM, Δ = 40.6 ± 9.21 % for MM). CONCLUSION: CTA and MRA have no significant differences in reproducing intracranial aneurysm geometry. The CFD results suggests there might be some significant differences in hemodynamic parameters between the three imaging-based models and this needs to be considered when interpreting the CFD results of different imaging-based models. If we only need to study the main flow patterns, three types of image-based model might be all suitable for patient-specific computational modeling studies.
format Online
Article
Text
id pubmed-4858827
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-48588272016-05-07 Reproducibility of image-based computational models of intracranial aneurysm: a comparison between 3D rotational angiography, CT angiography and MR angiography Ren, Yuan Chen, Guo-Zhong Liu, Zhen Cai, Yan Lu, Guang-Ming Li, Zhi-Yong Biomed Eng Online Research BACKGROUND: Reconstruction of patient-specific biomechanical model of intracranial aneurysm has been based on different imaging modalities. However, different imaging techniques may influence the model geometry and the computational fluid dynamics (CFD) simulation. The aim of this study is to evaluate the differences of the morphological and hemodynamic parameters in the computational models reconstructed from computed tomography angiography (CTA), magnetic resonance angiography (MRA) and 3D rotational angiography (3DRA). METHODS: Ten patients with cerebral aneurysms were enrolled in the study. MRA, CTA and 3DRA were performed on all patients. For each patient, three patient-specific models were reconstructed respectively based on the three sets of imaging data of the patient. CFD simulations were performed on each model. Model geometry and hemodynamic parameters were compared between the three models. RESULTS: In terms of morphological parameters, by comparing CTA based models (CM) and 3DRA based models (DM) which were treated as the “standard models”, the aspect ratio had the minimum difference (Δ = 8.3 ± 1.72 %, P = 0.953) and the surface distance was 0.25 ± 0.07 mm. Meanwhile, by comparing MRA based models (MM) and DM, the size had the minimum difference (Δ = 6.6 ± 1.85 %, P = 0.683) and the surface distance was 0.36 ± 0.1 mm. In respect of hemodynamic parameters, all three models showed a similar distribution: low average WSS at the sack, high OSI at the body and high average WSSG at the neck. However, there was a large variation in the average WSS (Δ = 34 ± 5.13 % for CM, Δ = 40.6 ± 9.21 % for MM). CONCLUSION: CTA and MRA have no significant differences in reproducing intracranial aneurysm geometry. The CFD results suggests there might be some significant differences in hemodynamic parameters between the three imaging-based models and this needs to be considered when interpreting the CFD results of different imaging-based models. If we only need to study the main flow patterns, three types of image-based model might be all suitable for patient-specific computational modeling studies. BioMed Central 2016-05-06 /pmc/articles/PMC4858827/ /pubmed/27150439 http://dx.doi.org/10.1186/s12938-016-0163-4 Text en © Ren et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Ren, Yuan
Chen, Guo-Zhong
Liu, Zhen
Cai, Yan
Lu, Guang-Ming
Li, Zhi-Yong
Reproducibility of image-based computational models of intracranial aneurysm: a comparison between 3D rotational angiography, CT angiography and MR angiography
title Reproducibility of image-based computational models of intracranial aneurysm: a comparison between 3D rotational angiography, CT angiography and MR angiography
title_full Reproducibility of image-based computational models of intracranial aneurysm: a comparison between 3D rotational angiography, CT angiography and MR angiography
title_fullStr Reproducibility of image-based computational models of intracranial aneurysm: a comparison between 3D rotational angiography, CT angiography and MR angiography
title_full_unstemmed Reproducibility of image-based computational models of intracranial aneurysm: a comparison between 3D rotational angiography, CT angiography and MR angiography
title_short Reproducibility of image-based computational models of intracranial aneurysm: a comparison between 3D rotational angiography, CT angiography and MR angiography
title_sort reproducibility of image-based computational models of intracranial aneurysm: a comparison between 3d rotational angiography, ct angiography and mr angiography
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4858827/
https://www.ncbi.nlm.nih.gov/pubmed/27150439
http://dx.doi.org/10.1186/s12938-016-0163-4
work_keys_str_mv AT renyuan reproducibilityofimagebasedcomputationalmodelsofintracranialaneurysmacomparisonbetween3drotationalangiographyctangiographyandmrangiography
AT chenguozhong reproducibilityofimagebasedcomputationalmodelsofintracranialaneurysmacomparisonbetween3drotationalangiographyctangiographyandmrangiography
AT liuzhen reproducibilityofimagebasedcomputationalmodelsofintracranialaneurysmacomparisonbetween3drotationalangiographyctangiographyandmrangiography
AT caiyan reproducibilityofimagebasedcomputationalmodelsofintracranialaneurysmacomparisonbetween3drotationalangiographyctangiographyandmrangiography
AT luguangming reproducibilityofimagebasedcomputationalmodelsofintracranialaneurysmacomparisonbetween3drotationalangiographyctangiographyandmrangiography
AT lizhiyong reproducibilityofimagebasedcomputationalmodelsofintracranialaneurysmacomparisonbetween3drotationalangiographyctangiographyandmrangiography