Cargando…

Water Calorimetry: A Correction to the Heat Defect Calculations

In a recent publication, we used a reaction model (model III) to calculate the heat defect for the irradiation of aqueous solutions with ionizing radiation at 21 °C. Subsequent work has revealed that the literature value used for one of the rate constants in the model was incorrect. A revised model...

Descripción completa

Detalles Bibliográficos
Autores principales: Klassen, Norman V., Ross, Carl K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2002
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4859257/
https://www.ncbi.nlm.nih.gov/pubmed/27446725
http://dx.doi.org/10.6028/jres.107.015
_version_ 1782430938449313792
author Klassen, Norman V.
Ross, Carl K.
author_facet Klassen, Norman V.
Ross, Carl K.
author_sort Klassen, Norman V.
collection PubMed
description In a recent publication, we used a reaction model (model III) to calculate the heat defect for the irradiation of aqueous solutions with ionizing radiation at 21 °C. Subsequent work has revealed that the literature value used for one of the rate constants in the model was incorrect. A revised model (model IIIR) incorporates the correct rate constant for 21 °C. Versions of models III and IIIR were created for irradiations at 4 °C. For our current water calorimetry protocol, the values of the heat defect for H(2)/O(2)-water (water saturated with a flow of 43 % H(2) and 57 % O(2), by volume) at 21 °C predicted by model III and model IIIR are similar but the value for 4 °C predicted by III is 30 % smaller than the value predicted by IIIR. Model IIIR predicts that the values of the heat defect at 21 °C and 4 °C lie within the range −0.023±0.002, in agreement with the values obtained from our water calorimetry measurements done using pure water and H(2)-saturated water at 21 °C and 4 °C. The yields of hydrogen peroxide in H(2)/O(2)-water at 21 °C and 4 °C were measured and agree with the predictions of model IIIR. Our water calorimetry measurements made with pure water and H(2)-saturated water are now of sufficient quality that they can be used to determine the heat defect for H(2)/O(2)-water better than can be done by simulations. However, consistency between the three systems continues to be an excellent check on water purity which is crucial, especially for the pure water system.
format Online
Article
Text
id pubmed-4859257
institution National Center for Biotechnology Information
language English
publishDate 2002
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-48592572016-07-21 Water Calorimetry: A Correction to the Heat Defect Calculations Klassen, Norman V. Ross, Carl K. J Res Natl Inst Stand Technol Article In a recent publication, we used a reaction model (model III) to calculate the heat defect for the irradiation of aqueous solutions with ionizing radiation at 21 °C. Subsequent work has revealed that the literature value used for one of the rate constants in the model was incorrect. A revised model (model IIIR) incorporates the correct rate constant for 21 °C. Versions of models III and IIIR were created for irradiations at 4 °C. For our current water calorimetry protocol, the values of the heat defect for H(2)/O(2)-water (water saturated with a flow of 43 % H(2) and 57 % O(2), by volume) at 21 °C predicted by model III and model IIIR are similar but the value for 4 °C predicted by III is 30 % smaller than the value predicted by IIIR. Model IIIR predicts that the values of the heat defect at 21 °C and 4 °C lie within the range −0.023±0.002, in agreement with the values obtained from our water calorimetry measurements done using pure water and H(2)-saturated water at 21 °C and 4 °C. The yields of hydrogen peroxide in H(2)/O(2)-water at 21 °C and 4 °C were measured and agree with the predictions of model IIIR. Our water calorimetry measurements made with pure water and H(2)-saturated water are now of sufficient quality that they can be used to determine the heat defect for H(2)/O(2)-water better than can be done by simulations. However, consistency between the three systems continues to be an excellent check on water purity which is crucial, especially for the pure water system. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2002 2002-04-01 /pmc/articles/PMC4859257/ /pubmed/27446725 http://dx.doi.org/10.6028/jres.107.015 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Klassen, Norman V.
Ross, Carl K.
Water Calorimetry: A Correction to the Heat Defect Calculations
title Water Calorimetry: A Correction to the Heat Defect Calculations
title_full Water Calorimetry: A Correction to the Heat Defect Calculations
title_fullStr Water Calorimetry: A Correction to the Heat Defect Calculations
title_full_unstemmed Water Calorimetry: A Correction to the Heat Defect Calculations
title_short Water Calorimetry: A Correction to the Heat Defect Calculations
title_sort water calorimetry: a correction to the heat defect calculations
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4859257/
https://www.ncbi.nlm.nih.gov/pubmed/27446725
http://dx.doi.org/10.6028/jres.107.015
work_keys_str_mv AT klassennormanv watercalorimetryacorrectiontotheheatdefectcalculations
AT rosscarlk watercalorimetryacorrectiontotheheatdefectcalculations