Cargando…

Diagnostic Accuracy of Tissue Doppler Index E/è for Evaluating Left Ventricular Filling Pressure and Diastolic Dysfunction/Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta‐Analysis

BACKGROUND: Tissue Doppler index E/è is used clinically and in multidisciplinary research for estimation of left ventricular filling pressure (LVFP) and diastolic dysfunction (DD)/heart failure with preserved ejection fraction (HFpEF). Its diagnostic accuracy is not well studied. METHODS AND RESULTS...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharifov, Oleg F., Schiros, Chun G., Aban, Inmaculada, Denney, Thomas S., Gupta, Himanshu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4859370/
https://www.ncbi.nlm.nih.gov/pubmed/26811160
http://dx.doi.org/10.1161/JAHA.115.002530
_version_ 1782430953075900416
author Sharifov, Oleg F.
Schiros, Chun G.
Aban, Inmaculada
Denney, Thomas S.
Gupta, Himanshu
author_facet Sharifov, Oleg F.
Schiros, Chun G.
Aban, Inmaculada
Denney, Thomas S.
Gupta, Himanshu
author_sort Sharifov, Oleg F.
collection PubMed
description BACKGROUND: Tissue Doppler index E/è is used clinically and in multidisciplinary research for estimation of left ventricular filling pressure (LVFP) and diastolic dysfunction (DD)/heart failure with preserved ejection fraction (HFpEF). Its diagnostic accuracy is not well studied. METHODS AND RESULTS: From the PubMed, Scopus, Embase, and Cochrane databases, we identified 24 studies reporting E/è and invasive LVFP in preserved EF (≥50%). In random‐effects models, E/è had poor to mediocre linear correlation with LVFP. Summary sensitivity and specificity (with 95% CIs) for the American Society of Echocardiography–recommended E/è cutoffs (lateral, mean, and septal, respectively) to identify elevated LVFP was estimated by using hierarchical summary receiver operating characteristic analysis. Summary sensitivity was 30% (9–48%), 37% (13–61%), and 24% (6–46%), and summary specificity was 92% (82–100%), 91% (80–99%), and 98% (92–100%). Positive likelihood ratio (LR+) was <5 for lateral and mean E/è. LR+ was slightly >10 for septal E/è obtained from 4 studies (cumulative sample size <220). For excluding elevated LVFP, summary sensitivity for E/è (lateral, mean, and septal, respectively) was 64% (38–86%), 36% (3–74%), and 50% (14–81%), while summary specificity was 73% (54–89%), 83% (49–100%), and 89% (66–100%). Because of data set limitations, meaningful inference for identifying HFpEF by using E/è could not be drawn. With the use of quality assessment tool for diagnostic accuracy studies (Quality Assessment of Diagnostic Accuracy Studies questionnaire), we found substantial risks of bias and/or applicability. CONCLUSIONS: There is insufficient evidence to support that E/è can reliably estimate LVFP in preserved EF. The diagnostic accuracy of E/è to identify/exclude elevated LVFP and DD/HFpEF is limited and requires further validation in a well‐designed prospective clinical trial.
format Online
Article
Text
id pubmed-4859370
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-48593702016-05-20 Diagnostic Accuracy of Tissue Doppler Index E/è for Evaluating Left Ventricular Filling Pressure and Diastolic Dysfunction/Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta‐Analysis Sharifov, Oleg F. Schiros, Chun G. Aban, Inmaculada Denney, Thomas S. Gupta, Himanshu J Am Heart Assoc Original Research BACKGROUND: Tissue Doppler index E/è is used clinically and in multidisciplinary research for estimation of left ventricular filling pressure (LVFP) and diastolic dysfunction (DD)/heart failure with preserved ejection fraction (HFpEF). Its diagnostic accuracy is not well studied. METHODS AND RESULTS: From the PubMed, Scopus, Embase, and Cochrane databases, we identified 24 studies reporting E/è and invasive LVFP in preserved EF (≥50%). In random‐effects models, E/è had poor to mediocre linear correlation with LVFP. Summary sensitivity and specificity (with 95% CIs) for the American Society of Echocardiography–recommended E/è cutoffs (lateral, mean, and septal, respectively) to identify elevated LVFP was estimated by using hierarchical summary receiver operating characteristic analysis. Summary sensitivity was 30% (9–48%), 37% (13–61%), and 24% (6–46%), and summary specificity was 92% (82–100%), 91% (80–99%), and 98% (92–100%). Positive likelihood ratio (LR+) was <5 for lateral and mean E/è. LR+ was slightly >10 for septal E/è obtained from 4 studies (cumulative sample size <220). For excluding elevated LVFP, summary sensitivity for E/è (lateral, mean, and septal, respectively) was 64% (38–86%), 36% (3–74%), and 50% (14–81%), while summary specificity was 73% (54–89%), 83% (49–100%), and 89% (66–100%). Because of data set limitations, meaningful inference for identifying HFpEF by using E/è could not be drawn. With the use of quality assessment tool for diagnostic accuracy studies (Quality Assessment of Diagnostic Accuracy Studies questionnaire), we found substantial risks of bias and/or applicability. CONCLUSIONS: There is insufficient evidence to support that E/è can reliably estimate LVFP in preserved EF. The diagnostic accuracy of E/è to identify/exclude elevated LVFP and DD/HFpEF is limited and requires further validation in a well‐designed prospective clinical trial. John Wiley and Sons Inc. 2016-01-25 /pmc/articles/PMC4859370/ /pubmed/26811160 http://dx.doi.org/10.1161/JAHA.115.002530 Text en © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial (http://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Research
Sharifov, Oleg F.
Schiros, Chun G.
Aban, Inmaculada
Denney, Thomas S.
Gupta, Himanshu
Diagnostic Accuracy of Tissue Doppler Index E/è for Evaluating Left Ventricular Filling Pressure and Diastolic Dysfunction/Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta‐Analysis
title Diagnostic Accuracy of Tissue Doppler Index E/è for Evaluating Left Ventricular Filling Pressure and Diastolic Dysfunction/Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta‐Analysis
title_full Diagnostic Accuracy of Tissue Doppler Index E/è for Evaluating Left Ventricular Filling Pressure and Diastolic Dysfunction/Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta‐Analysis
title_fullStr Diagnostic Accuracy of Tissue Doppler Index E/è for Evaluating Left Ventricular Filling Pressure and Diastolic Dysfunction/Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta‐Analysis
title_full_unstemmed Diagnostic Accuracy of Tissue Doppler Index E/è for Evaluating Left Ventricular Filling Pressure and Diastolic Dysfunction/Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta‐Analysis
title_short Diagnostic Accuracy of Tissue Doppler Index E/è for Evaluating Left Ventricular Filling Pressure and Diastolic Dysfunction/Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta‐Analysis
title_sort diagnostic accuracy of tissue doppler index e/è for evaluating left ventricular filling pressure and diastolic dysfunction/heart failure with preserved ejection fraction: a systematic review and meta‐analysis
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4859370/
https://www.ncbi.nlm.nih.gov/pubmed/26811160
http://dx.doi.org/10.1161/JAHA.115.002530
work_keys_str_mv AT sharifovolegf diagnosticaccuracyoftissuedopplerindexeeforevaluatingleftventricularfillingpressureanddiastolicdysfunctionheartfailurewithpreservedejectionfractionasystematicreviewandmetaanalysis
AT schiroschung diagnosticaccuracyoftissuedopplerindexeeforevaluatingleftventricularfillingpressureanddiastolicdysfunctionheartfailurewithpreservedejectionfractionasystematicreviewandmetaanalysis
AT abaninmaculada diagnosticaccuracyoftissuedopplerindexeeforevaluatingleftventricularfillingpressureanddiastolicdysfunctionheartfailurewithpreservedejectionfractionasystematicreviewandmetaanalysis
AT denneythomass diagnosticaccuracyoftissuedopplerindexeeforevaluatingleftventricularfillingpressureanddiastolicdysfunctionheartfailurewithpreservedejectionfractionasystematicreviewandmetaanalysis
AT guptahimanshu diagnosticaccuracyoftissuedopplerindexeeforevaluatingleftventricularfillingpressureanddiastolicdysfunctionheartfailurewithpreservedejectionfractionasystematicreviewandmetaanalysis