Cargando…

The characteristics of circular disposable devices and in situ devices for optimizing male circumcision: a network meta-analysis

In situ device (ISD) and circular disposable device (CDD) are used for optimizing male circumcision (MC), but evidence to explore the characteristics of these two devices is insufficient. In order to explore this issue systematically and provide reliable evidence, ten published randomized controlled...

Descripción completa

Detalles Bibliográficos
Autores principales: Fan, Yu, Cao, Dehong, Wei, Qiang, Tang, Zhuang, Tan, Ping, Yang, Lu, Liu, Liangren, Liu, Zhenhua, Li, Xiang, Xue, Wenbin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4860598/
https://www.ncbi.nlm.nih.gov/pubmed/27156368
http://dx.doi.org/10.1038/srep25514
_version_ 1782431094500491264
author Fan, Yu
Cao, Dehong
Wei, Qiang
Tang, Zhuang
Tan, Ping
Yang, Lu
Liu, Liangren
Liu, Zhenhua
Li, Xiang
Xue, Wenbin
author_facet Fan, Yu
Cao, Dehong
Wei, Qiang
Tang, Zhuang
Tan, Ping
Yang, Lu
Liu, Liangren
Liu, Zhenhua
Li, Xiang
Xue, Wenbin
author_sort Fan, Yu
collection PubMed
description In situ device (ISD) and circular disposable device (CDD) are used for optimizing male circumcision (MC), but evidence to explore the characteristics of these two devices is insufficient. In order to explore this issue systematically and provide reliable evidence, ten published randomized controlled trials (RCTs) exploring the safety and efficacy of ISDs and CDDs were included (involving 4649 men). Moderate quality of the RCTs included was found after assessment. Pairwise meta-analyses and network meta-analyses were processed in stata 13.0 and AIDDS v1.16.6 respectively. According to the outcomes that were statistically significant in both pairwise and network meta-analyses, ISD was found to have less intraoperative blood loss (IB), less operative time (OT) and less incidence of wound bleeding (WB) than conventional circumcision (CC); ISD was found to have less WB but more wound healing time (WHT) than CDD; CDD was found to have less IB and less OT than CC. CDD tended to have the best wound healing condition and least pain experience; ISD tended to have the least IB, least OT, least WB, and highest satisfaction rate. With their own superiorities in many aspects, CDD and ISD are both safe and effective devices for optimizing MC.
format Online
Article
Text
id pubmed-4860598
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-48605982016-05-20 The characteristics of circular disposable devices and in situ devices for optimizing male circumcision: a network meta-analysis Fan, Yu Cao, Dehong Wei, Qiang Tang, Zhuang Tan, Ping Yang, Lu Liu, Liangren Liu, Zhenhua Li, Xiang Xue, Wenbin Sci Rep Article In situ device (ISD) and circular disposable device (CDD) are used for optimizing male circumcision (MC), but evidence to explore the characteristics of these two devices is insufficient. In order to explore this issue systematically and provide reliable evidence, ten published randomized controlled trials (RCTs) exploring the safety and efficacy of ISDs and CDDs were included (involving 4649 men). Moderate quality of the RCTs included was found after assessment. Pairwise meta-analyses and network meta-analyses were processed in stata 13.0 and AIDDS v1.16.6 respectively. According to the outcomes that were statistically significant in both pairwise and network meta-analyses, ISD was found to have less intraoperative blood loss (IB), less operative time (OT) and less incidence of wound bleeding (WB) than conventional circumcision (CC); ISD was found to have less WB but more wound healing time (WHT) than CDD; CDD was found to have less IB and less OT than CC. CDD tended to have the best wound healing condition and least pain experience; ISD tended to have the least IB, least OT, least WB, and highest satisfaction rate. With their own superiorities in many aspects, CDD and ISD are both safe and effective devices for optimizing MC. Nature Publishing Group 2016-05-09 /pmc/articles/PMC4860598/ /pubmed/27156368 http://dx.doi.org/10.1038/srep25514 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Fan, Yu
Cao, Dehong
Wei, Qiang
Tang, Zhuang
Tan, Ping
Yang, Lu
Liu, Liangren
Liu, Zhenhua
Li, Xiang
Xue, Wenbin
The characteristics of circular disposable devices and in situ devices for optimizing male circumcision: a network meta-analysis
title The characteristics of circular disposable devices and in situ devices for optimizing male circumcision: a network meta-analysis
title_full The characteristics of circular disposable devices and in situ devices for optimizing male circumcision: a network meta-analysis
title_fullStr The characteristics of circular disposable devices and in situ devices for optimizing male circumcision: a network meta-analysis
title_full_unstemmed The characteristics of circular disposable devices and in situ devices for optimizing male circumcision: a network meta-analysis
title_short The characteristics of circular disposable devices and in situ devices for optimizing male circumcision: a network meta-analysis
title_sort characteristics of circular disposable devices and in situ devices for optimizing male circumcision: a network meta-analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4860598/
https://www.ncbi.nlm.nih.gov/pubmed/27156368
http://dx.doi.org/10.1038/srep25514
work_keys_str_mv AT fanyu thecharacteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT caodehong thecharacteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT weiqiang thecharacteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT tangzhuang thecharacteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT tanping thecharacteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT yanglu thecharacteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT liuliangren thecharacteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT liuzhenhua thecharacteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT lixiang thecharacteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT xuewenbin thecharacteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT fanyu characteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT caodehong characteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT weiqiang characteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT tangzhuang characteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT tanping characteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT yanglu characteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT liuliangren characteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT liuzhenhua characteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT lixiang characteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis
AT xuewenbin characteristicsofcirculardisposabledevicesandinsitudevicesforoptimizingmalecircumcisionanetworkmetaanalysis