The influence of probe level on the tuning of stimulus frequency otoacoustic emissions and behavioral test in human

BACKGROUND: Frequency selectivity (FS) of the auditory system is established at the level of the cochlea and it is important for the perception of complex sounds. Although direct measurements of cochlear FS require surgical preparation, it can also be estimated with the measurements of otoacoustic e...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Yao, Gong, Qin, Zhang, Tao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4862048/
https://www.ncbi.nlm.nih.gov/pubmed/27160830
http://dx.doi.org/10.1186/s12938-016-0167-0
_version_ 1782431297135706112
author Wang, Yao
Gong, Qin
Zhang, Tao
author_facet Wang, Yao
Gong, Qin
Zhang, Tao
author_sort Wang, Yao
collection PubMed
description BACKGROUND: Frequency selectivity (FS) of the auditory system is established at the level of the cochlea and it is important for the perception of complex sounds. Although direct measurements of cochlear FS require surgical preparation, it can also be estimated with the measurements of otoacoustic emissions or behavioral tests, including stimulus frequency otoacoustic emission suppression tuning curves (SFOAE STCs) or psychophysical tuning curves (PTCs). These two methods result in similar estimates of FS at low probe levels. As the compressive nonlinearity of cochlea is strongly dependent on the stimulus intensity, the sharpness of tuning curves which is relevant to the cochlear nonlinearity will change as a function of probe level. The present study aims to investigate the influence of different probe levels on the relationship between SFOAE STCs and PTCs. METHODS: The study included 15 young subjects with normal hearing. SFOAE STCs and PTCs were recorded at low and moderate probe levels for frequencies centred at 1, 2, and 4 kHz. The ratio or the difference of the characteristic parameters between the two methods was calculated at each probe level. The effect of probe level on the ratio or the difference between the parameters of SFOAE STCs and PTCs was then statistically analysed. RESULTS: The tuning of SFOAE STCs was significantly positively correlated with the tuning of the PTCs at both low and moderate probe levels; yet, at the moderate probe level, the SFOAE STCs were consistently broader than the PTCs. The mean ratio of sharpness of tuning at low probe levels was constantly around 1 while around 1.5 at moderate probe levels. CONCLUSIONS: Probe level had a significant effect on the sharpness of tuning between the two methods of estimating FS. SFOAE STC seems a good alternative measurement of PTC for FS assessment at low probe levels. At moderate probe levels, SFOAE STC and PTC were not equivalent measures of the FS in terms of their bandwidths. Because SFOAE STCs are not biased by higher levels auditory processing, they may represent cochlear FS better than PTCs.
format Online
Article
Text
id pubmed-4862048
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-48620482016-05-11 The influence of probe level on the tuning of stimulus frequency otoacoustic emissions and behavioral test in human Wang, Yao Gong, Qin Zhang, Tao Biomed Eng Online Research BACKGROUND: Frequency selectivity (FS) of the auditory system is established at the level of the cochlea and it is important for the perception of complex sounds. Although direct measurements of cochlear FS require surgical preparation, it can also be estimated with the measurements of otoacoustic emissions or behavioral tests, including stimulus frequency otoacoustic emission suppression tuning curves (SFOAE STCs) or psychophysical tuning curves (PTCs). These two methods result in similar estimates of FS at low probe levels. As the compressive nonlinearity of cochlea is strongly dependent on the stimulus intensity, the sharpness of tuning curves which is relevant to the cochlear nonlinearity will change as a function of probe level. The present study aims to investigate the influence of different probe levels on the relationship between SFOAE STCs and PTCs. METHODS: The study included 15 young subjects with normal hearing. SFOAE STCs and PTCs were recorded at low and moderate probe levels for frequencies centred at 1, 2, and 4 kHz. The ratio or the difference of the characteristic parameters between the two methods was calculated at each probe level. The effect of probe level on the ratio or the difference between the parameters of SFOAE STCs and PTCs was then statistically analysed. RESULTS: The tuning of SFOAE STCs was significantly positively correlated with the tuning of the PTCs at both low and moderate probe levels; yet, at the moderate probe level, the SFOAE STCs were consistently broader than the PTCs. The mean ratio of sharpness of tuning at low probe levels was constantly around 1 while around 1.5 at moderate probe levels. CONCLUSIONS: Probe level had a significant effect on the sharpness of tuning between the two methods of estimating FS. SFOAE STC seems a good alternative measurement of PTC for FS assessment at low probe levels. At moderate probe levels, SFOAE STC and PTC were not equivalent measures of the FS in terms of their bandwidths. Because SFOAE STCs are not biased by higher levels auditory processing, they may represent cochlear FS better than PTCs. BioMed Central 2016-05-10 /pmc/articles/PMC4862048/ /pubmed/27160830 http://dx.doi.org/10.1186/s12938-016-0167-0 Text en © Wang et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Wang, Yao
Gong, Qin
Zhang, Tao
The influence of probe level on the tuning of stimulus frequency otoacoustic emissions and behavioral test in human
title The influence of probe level on the tuning of stimulus frequency otoacoustic emissions and behavioral test in human
title_full The influence of probe level on the tuning of stimulus frequency otoacoustic emissions and behavioral test in human
title_fullStr The influence of probe level on the tuning of stimulus frequency otoacoustic emissions and behavioral test in human
title_full_unstemmed The influence of probe level on the tuning of stimulus frequency otoacoustic emissions and behavioral test in human
title_short The influence of probe level on the tuning of stimulus frequency otoacoustic emissions and behavioral test in human
title_sort influence of probe level on the tuning of stimulus frequency otoacoustic emissions and behavioral test in human
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4862048/
https://www.ncbi.nlm.nih.gov/pubmed/27160830
http://dx.doi.org/10.1186/s12938-016-0167-0
work_keys_str_mv AT wangyao theinfluenceofprobelevelonthetuningofstimulusfrequencyotoacousticemissionsandbehavioraltestinhuman
AT gongqin theinfluenceofprobelevelonthetuningofstimulusfrequencyotoacousticemissionsandbehavioraltestinhuman
AT zhangtao theinfluenceofprobelevelonthetuningofstimulusfrequencyotoacousticemissionsandbehavioraltestinhuman
AT wangyao influenceofprobelevelonthetuningofstimulusfrequencyotoacousticemissionsandbehavioraltestinhuman
AT gongqin influenceofprobelevelonthetuningofstimulusfrequencyotoacousticemissionsandbehavioraltestinhuman
AT zhangtao influenceofprobelevelonthetuningofstimulusfrequencyotoacousticemissionsandbehavioraltestinhuman