Design, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants

BACKGROUND: Laryngo-pharyngeal mechano-sensitivity (LPMS) is involved in dysphagia, sleep apnea, stroke, irritable larynx syndrome and cough hypersensitivity syndrome among other disorders. These conditions are associated with a wide range of airway reflex abnormalities. However, the current device...

Descripción completa

Detalles Bibliográficos
Autores principales: Giraldo-Cadavid, Luis F., Agudelo-Otalora, Luis Mauricio, Burguete, Javier, Arbulu, Mario, Moscoso, William Daniel, Martínez, Fabio, Ortiz, Andrés Felipe, Diaz, Juan, Pantoja, Jaime A., Rueda-Arango, Andrés Felipe, Fernández, Secundino
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4862145/
https://www.ncbi.nlm.nih.gov/pubmed/27160751
http://dx.doi.org/10.1186/s12938-016-0166-1
_version_ 1782431315264536576
author Giraldo-Cadavid, Luis F.
Agudelo-Otalora, Luis Mauricio
Burguete, Javier
Arbulu, Mario
Moscoso, William Daniel
Martínez, Fabio
Ortiz, Andrés Felipe
Diaz, Juan
Pantoja, Jaime A.
Rueda-Arango, Andrés Felipe
Fernández, Secundino
author_facet Giraldo-Cadavid, Luis F.
Agudelo-Otalora, Luis Mauricio
Burguete, Javier
Arbulu, Mario
Moscoso, William Daniel
Martínez, Fabio
Ortiz, Andrés Felipe
Diaz, Juan
Pantoja, Jaime A.
Rueda-Arango, Andrés Felipe
Fernández, Secundino
author_sort Giraldo-Cadavid, Luis F.
collection PubMed
description BACKGROUND: Laryngo-pharyngeal mechano-sensitivity (LPMS) is involved in dysphagia, sleep apnea, stroke, irritable larynx syndrome and cough hypersensitivity syndrome among other disorders. These conditions are associated with a wide range of airway reflex abnormalities. However, the current device for exploring LPMS is limited because it assesses only the laryngeal adductor reflex during fiber-optic endoscopic evaluations of swallowing and requires a high degree of expertise to obtain reliable results, introducing intrinsic expert variability and subjectivity. METHODS: We designed, developed and validated a new air-pulse laryngo-pharyngeal endoscopic esthesiometer with a built-in laser range-finder (LPEER) based on the evaluation and control of air-pulse variability determinants and on intrinsic observer variability and subjectivity determinants of the distance, angle and site of stimulus impact. The LPEER was designed to be capable of delivering precise and accurate stimuli with a wide range of intensities that can explore most laryngo-pharyngeal reflexes. RESULTS: We initially explored the potential factors affecting the reliability of LPMS tests and included these factors in a multiple linear regression model. The following factors significantly affected the precision and accuracy of the test (P < 0.001): the tube conducting the air-pulses, the supply pressure of the system, the duration of the air-pulses, and the distance and angle between the end of the tube conducting the air-pulses and the site of impact. To control all of these factors, an LPEER consisting of an air-pulse generator and an endoscopic laser range-finder was designed and manufactured. We assessed the precision and accuracy of the LPEER’s stimulus and range-finder according to the coefficient of variation (CV) and by looking at the differences between the measured properties and the desired values, and we performed a pilot validation on ten human subjects. The air-pulses and range-finder exhibited good precision and accuracy (CV < 0.06), with differences between the desired and measured properties at <3 % and a range-finder measurement error of <1 mm. The tests in patients demonstrated obtainable and reproducible thresholds for the laryngeal adductor, cough and gag reflexes. CONCLUSIONS: The new LPEER was capable of delivering precise and accurate stimuli for exploring laryngo-pharyngeal reflexes.
format Online
Article
Text
id pubmed-4862145
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-48621452016-05-11 Design, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants Giraldo-Cadavid, Luis F. Agudelo-Otalora, Luis Mauricio Burguete, Javier Arbulu, Mario Moscoso, William Daniel Martínez, Fabio Ortiz, Andrés Felipe Diaz, Juan Pantoja, Jaime A. Rueda-Arango, Andrés Felipe Fernández, Secundino Biomed Eng Online Research BACKGROUND: Laryngo-pharyngeal mechano-sensitivity (LPMS) is involved in dysphagia, sleep apnea, stroke, irritable larynx syndrome and cough hypersensitivity syndrome among other disorders. These conditions are associated with a wide range of airway reflex abnormalities. However, the current device for exploring LPMS is limited because it assesses only the laryngeal adductor reflex during fiber-optic endoscopic evaluations of swallowing and requires a high degree of expertise to obtain reliable results, introducing intrinsic expert variability and subjectivity. METHODS: We designed, developed and validated a new air-pulse laryngo-pharyngeal endoscopic esthesiometer with a built-in laser range-finder (LPEER) based on the evaluation and control of air-pulse variability determinants and on intrinsic observer variability and subjectivity determinants of the distance, angle and site of stimulus impact. The LPEER was designed to be capable of delivering precise and accurate stimuli with a wide range of intensities that can explore most laryngo-pharyngeal reflexes. RESULTS: We initially explored the potential factors affecting the reliability of LPMS tests and included these factors in a multiple linear regression model. The following factors significantly affected the precision and accuracy of the test (P < 0.001): the tube conducting the air-pulses, the supply pressure of the system, the duration of the air-pulses, and the distance and angle between the end of the tube conducting the air-pulses and the site of impact. To control all of these factors, an LPEER consisting of an air-pulse generator and an endoscopic laser range-finder was designed and manufactured. We assessed the precision and accuracy of the LPEER’s stimulus and range-finder according to the coefficient of variation (CV) and by looking at the differences between the measured properties and the desired values, and we performed a pilot validation on ten human subjects. The air-pulses and range-finder exhibited good precision and accuracy (CV < 0.06), with differences between the desired and measured properties at <3 % and a range-finder measurement error of <1 mm. The tests in patients demonstrated obtainable and reproducible thresholds for the laryngeal adductor, cough and gag reflexes. CONCLUSIONS: The new LPEER was capable of delivering precise and accurate stimuli for exploring laryngo-pharyngeal reflexes. BioMed Central 2016-05-10 /pmc/articles/PMC4862145/ /pubmed/27160751 http://dx.doi.org/10.1186/s12938-016-0166-1 Text en © Giraldo-Cadavid et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Giraldo-Cadavid, Luis F.
Agudelo-Otalora, Luis Mauricio
Burguete, Javier
Arbulu, Mario
Moscoso, William Daniel
Martínez, Fabio
Ortiz, Andrés Felipe
Diaz, Juan
Pantoja, Jaime A.
Rueda-Arango, Andrés Felipe
Fernández, Secundino
Design, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants
title Design, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants
title_full Design, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants
title_fullStr Design, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants
title_full_unstemmed Design, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants
title_short Design, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants
title_sort design, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4862145/
https://www.ncbi.nlm.nih.gov/pubmed/27160751
http://dx.doi.org/10.1186/s12938-016-0166-1
work_keys_str_mv AT giraldocadavidluisf designdevelopmentandvalidationofanewlaryngopharyngealendoscopicesthesiometerandrangefinderbasedontheassessmentofairpulsevariabilitydeterminants
AT agudelootaloraluismauricio designdevelopmentandvalidationofanewlaryngopharyngealendoscopicesthesiometerandrangefinderbasedontheassessmentofairpulsevariabilitydeterminants
AT burguetejavier designdevelopmentandvalidationofanewlaryngopharyngealendoscopicesthesiometerandrangefinderbasedontheassessmentofairpulsevariabilitydeterminants
AT arbulumario designdevelopmentandvalidationofanewlaryngopharyngealendoscopicesthesiometerandrangefinderbasedontheassessmentofairpulsevariabilitydeterminants
AT moscosowilliamdaniel designdevelopmentandvalidationofanewlaryngopharyngealendoscopicesthesiometerandrangefinderbasedontheassessmentofairpulsevariabilitydeterminants
AT martinezfabio designdevelopmentandvalidationofanewlaryngopharyngealendoscopicesthesiometerandrangefinderbasedontheassessmentofairpulsevariabilitydeterminants
AT ortizandresfelipe designdevelopmentandvalidationofanewlaryngopharyngealendoscopicesthesiometerandrangefinderbasedontheassessmentofairpulsevariabilitydeterminants
AT diazjuan designdevelopmentandvalidationofanewlaryngopharyngealendoscopicesthesiometerandrangefinderbasedontheassessmentofairpulsevariabilitydeterminants
AT pantojajaimea designdevelopmentandvalidationofanewlaryngopharyngealendoscopicesthesiometerandrangefinderbasedontheassessmentofairpulsevariabilitydeterminants
AT ruedaarangoandresfelipe designdevelopmentandvalidationofanewlaryngopharyngealendoscopicesthesiometerandrangefinderbasedontheassessmentofairpulsevariabilitydeterminants
AT fernandezsecundino designdevelopmentandvalidationofanewlaryngopharyngealendoscopicesthesiometerandrangefinderbasedontheassessmentofairpulsevariabilitydeterminants