Cargando…

Assessment of aortic valve in regard to its anatomical variants morphology in 2053 patients using 64-slice CT retrospective coronary angiography

BACKGROUND: Bicuspid aortic valve (BAV) is the most common congenital cardiac anomaly. Other aortic valve variants are rare but are associated with an increased incidence of various pathologies of the aortic valve (AV). The aim of this study was to assess the AV function in regard to its anatomical...

Descripción completa

Detalles Bibliográficos
Autores principales: Szymczyk, Konrad, Polguj, Michał, Szymczyk, Ewa, Bakoń, Leopold, Pacho, Ryszard, Stefańczyk, Ludomir
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4862224/
https://www.ncbi.nlm.nih.gov/pubmed/27165721
http://dx.doi.org/10.1186/s12872-016-0261-z
_version_ 1782431331478667264
author Szymczyk, Konrad
Polguj, Michał
Szymczyk, Ewa
Bakoń, Leopold
Pacho, Ryszard
Stefańczyk, Ludomir
author_facet Szymczyk, Konrad
Polguj, Michał
Szymczyk, Ewa
Bakoń, Leopold
Pacho, Ryszard
Stefańczyk, Ludomir
author_sort Szymczyk, Konrad
collection PubMed
description BACKGROUND: Bicuspid aortic valve (BAV) is the most common congenital cardiac anomaly. Other aortic valve variants are rare but are associated with an increased incidence of various pathologies of the aortic valve (AV). The aim of this study was to assess the AV function in regard to its anatomical variants morphology in patients who underwent 64-slice coronary computed tomography angiography (CCTA) for suspected or known coronary artery disease. METHODS: The results of 64-detector retrospective ECG-gated CCTA of 2053 patients (mean age 58 years; 1265 males) were analyzed retrospectively by experienced cardiovascular radiologist. Coronary anatomy (with coronary artery dominance) and the extent of occlusion in the coronary arteries were assessed. Furthermore morphological and functional status of AV variants were analyzed. Among measured parameters were area at the level of AV annulus, orifice and tubular portion of the ascending aorta. RESULTS: The AV was visualized in all CCTA studies and the analysis of its morphology and function was done in all patients. BAV was found in 19 patients (0.9 %), from which type 0 was diagnosed in five patients (0.2 %) and type 1 in 14 patients (0.7 %) - there was no patient with BAV type 2. Unicuspid (UAV) and quadricuspid (QAV) variant were both observed each in one patient (0.05 %). In rest of the patients from the study group tricuspid AV variant was recognized. Function of AV variants was mostly affected in BAV0 and UAV. Among patients with BAV1 there were patients with normal and abnormal function of AV. QAV variant did not deteriorate AV function. There was no difference in coronary artery disease and dominancy between different anatomical variants of AV. CONCLUSIONS: During CCTA different valve variants can be detected and detailed analysis of valvular function can be proceeded. Larger values of annulus area, wider diameters of ascending aorta and more stenotic profile were observed in BAV 0, BAV 1 and UAV. Among AV variants morphology and function was mostly affected in patients with BAV 0 and UAV variants, while subjects with BAV1 had normal or abnormal function of the AV. Moreover, we noticed that QAV variant did not deteriorate AV function. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12872-016-0261-z) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4862224
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-48622242016-05-11 Assessment of aortic valve in regard to its anatomical variants morphology in 2053 patients using 64-slice CT retrospective coronary angiography Szymczyk, Konrad Polguj, Michał Szymczyk, Ewa Bakoń, Leopold Pacho, Ryszard Stefańczyk, Ludomir BMC Cardiovasc Disord Research Article BACKGROUND: Bicuspid aortic valve (BAV) is the most common congenital cardiac anomaly. Other aortic valve variants are rare but are associated with an increased incidence of various pathologies of the aortic valve (AV). The aim of this study was to assess the AV function in regard to its anatomical variants morphology in patients who underwent 64-slice coronary computed tomography angiography (CCTA) for suspected or known coronary artery disease. METHODS: The results of 64-detector retrospective ECG-gated CCTA of 2053 patients (mean age 58 years; 1265 males) were analyzed retrospectively by experienced cardiovascular radiologist. Coronary anatomy (with coronary artery dominance) and the extent of occlusion in the coronary arteries were assessed. Furthermore morphological and functional status of AV variants were analyzed. Among measured parameters were area at the level of AV annulus, orifice and tubular portion of the ascending aorta. RESULTS: The AV was visualized in all CCTA studies and the analysis of its morphology and function was done in all patients. BAV was found in 19 patients (0.9 %), from which type 0 was diagnosed in five patients (0.2 %) and type 1 in 14 patients (0.7 %) - there was no patient with BAV type 2. Unicuspid (UAV) and quadricuspid (QAV) variant were both observed each in one patient (0.05 %). In rest of the patients from the study group tricuspid AV variant was recognized. Function of AV variants was mostly affected in BAV0 and UAV. Among patients with BAV1 there were patients with normal and abnormal function of AV. QAV variant did not deteriorate AV function. There was no difference in coronary artery disease and dominancy between different anatomical variants of AV. CONCLUSIONS: During CCTA different valve variants can be detected and detailed analysis of valvular function can be proceeded. Larger values of annulus area, wider diameters of ascending aorta and more stenotic profile were observed in BAV 0, BAV 1 and UAV. Among AV variants morphology and function was mostly affected in patients with BAV 0 and UAV variants, while subjects with BAV1 had normal or abnormal function of the AV. Moreover, we noticed that QAV variant did not deteriorate AV function. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12872-016-0261-z) contains supplementary material, which is available to authorized users. BioMed Central 2016-05-10 /pmc/articles/PMC4862224/ /pubmed/27165721 http://dx.doi.org/10.1186/s12872-016-0261-z Text en © Szymczyk et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Szymczyk, Konrad
Polguj, Michał
Szymczyk, Ewa
Bakoń, Leopold
Pacho, Ryszard
Stefańczyk, Ludomir
Assessment of aortic valve in regard to its anatomical variants morphology in 2053 patients using 64-slice CT retrospective coronary angiography
title Assessment of aortic valve in regard to its anatomical variants morphology in 2053 patients using 64-slice CT retrospective coronary angiography
title_full Assessment of aortic valve in regard to its anatomical variants morphology in 2053 patients using 64-slice CT retrospective coronary angiography
title_fullStr Assessment of aortic valve in regard to its anatomical variants morphology in 2053 patients using 64-slice CT retrospective coronary angiography
title_full_unstemmed Assessment of aortic valve in regard to its anatomical variants morphology in 2053 patients using 64-slice CT retrospective coronary angiography
title_short Assessment of aortic valve in regard to its anatomical variants morphology in 2053 patients using 64-slice CT retrospective coronary angiography
title_sort assessment of aortic valve in regard to its anatomical variants morphology in 2053 patients using 64-slice ct retrospective coronary angiography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4862224/
https://www.ncbi.nlm.nih.gov/pubmed/27165721
http://dx.doi.org/10.1186/s12872-016-0261-z
work_keys_str_mv AT szymczykkonrad assessmentofaorticvalveinregardtoitsanatomicalvariantsmorphologyin2053patientsusing64slicectretrospectivecoronaryangiography
AT polgujmichał assessmentofaorticvalveinregardtoitsanatomicalvariantsmorphologyin2053patientsusing64slicectretrospectivecoronaryangiography
AT szymczykewa assessmentofaorticvalveinregardtoitsanatomicalvariantsmorphologyin2053patientsusing64slicectretrospectivecoronaryangiography
AT bakonleopold assessmentofaorticvalveinregardtoitsanatomicalvariantsmorphologyin2053patientsusing64slicectretrospectivecoronaryangiography
AT pachoryszard assessmentofaorticvalveinregardtoitsanatomicalvariantsmorphologyin2053patientsusing64slicectretrospectivecoronaryangiography
AT stefanczykludomir assessmentofaorticvalveinregardtoitsanatomicalvariantsmorphologyin2053patientsusing64slicectretrospectivecoronaryangiography