Cargando…
A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis
Indirect calorimetry and oxygen consumption (VO(2)) are accepted tools in human physiology research. It has been shown that indirect calorimetry systems exhibit differential measurement error, where the error of a device is systematically different depending on the volume of gas flow. Moreover, syst...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4863070/ https://www.ncbi.nlm.nih.gov/pubmed/27242546 http://dx.doi.org/10.3389/fphys.2016.00172 |
_version_ | 1782431420997697536 |
---|---|
author | Tenan, Matthew S. |
author_facet | Tenan, Matthew S. |
author_sort | Tenan, Matthew S. |
collection | PubMed |
description | Indirect calorimetry and oxygen consumption (VO(2)) are accepted tools in human physiology research. It has been shown that indirect calorimetry systems exhibit differential measurement error, where the error of a device is systematically different depending on the volume of gas flow. Moreover, systems commonly report multiple decimal places of precision, giving the clinician a false sense of device accuracy. The purpose of this manuscript is to demonstrate the use of a novel statistical tool which models the reliability of two specific indirect calorimetry systems, Douglas bag and Parvomedics 2400 TrueOne, as univariate normal distributions and implements the distribution overlapping coefficient to determine the likelihood that two VO(2) measures are the same. A command line implementation of the tool is available for the R programming language as well as a web-based graphical user interface (GUI). This tool is valuable for clinicians performing a single-subject analysis as well as researchers interested in determining if their observed differences exceed the error of the device. |
format | Online Article Text |
id | pubmed-4863070 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-48630702016-05-30 A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis Tenan, Matthew S. Front Physiol Physiology Indirect calorimetry and oxygen consumption (VO(2)) are accepted tools in human physiology research. It has been shown that indirect calorimetry systems exhibit differential measurement error, where the error of a device is systematically different depending on the volume of gas flow. Moreover, systems commonly report multiple decimal places of precision, giving the clinician a false sense of device accuracy. The purpose of this manuscript is to demonstrate the use of a novel statistical tool which models the reliability of two specific indirect calorimetry systems, Douglas bag and Parvomedics 2400 TrueOne, as univariate normal distributions and implements the distribution overlapping coefficient to determine the likelihood that two VO(2) measures are the same. A command line implementation of the tool is available for the R programming language as well as a web-based graphical user interface (GUI). This tool is valuable for clinicians performing a single-subject analysis as well as researchers interested in determining if their observed differences exceed the error of the device. Frontiers Media S.A. 2016-05-11 /pmc/articles/PMC4863070/ /pubmed/27242546 http://dx.doi.org/10.3389/fphys.2016.00172 Text en Copyright © 2016 Tenan. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Tenan, Matthew S. A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis |
title | A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis |
title_full | A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis |
title_fullStr | A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis |
title_full_unstemmed | A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis |
title_short | A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis |
title_sort | statistical method and tool to account for indirect calorimetry differential measurement error in a single-subject analysis |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4863070/ https://www.ncbi.nlm.nih.gov/pubmed/27242546 http://dx.doi.org/10.3389/fphys.2016.00172 |
work_keys_str_mv | AT tenanmatthews astatisticalmethodandtooltoaccountforindirectcalorimetrydifferentialmeasurementerrorinasinglesubjectanalysis AT tenanmatthews statisticalmethodandtooltoaccountforindirectcalorimetrydifferentialmeasurementerrorinasinglesubjectanalysis |