A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis

Indirect calorimetry and oxygen consumption (VO(2)) are accepted tools in human physiology research. It has been shown that indirect calorimetry systems exhibit differential measurement error, where the error of a device is systematically different depending on the volume of gas flow. Moreover, syst...

Descripción completa

Detalles Bibliográficos
Autor principal: Tenan, Matthew S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4863070/
https://www.ncbi.nlm.nih.gov/pubmed/27242546
http://dx.doi.org/10.3389/fphys.2016.00172
_version_ 1782431420997697536
author Tenan, Matthew S.
author_facet Tenan, Matthew S.
author_sort Tenan, Matthew S.
collection PubMed
description Indirect calorimetry and oxygen consumption (VO(2)) are accepted tools in human physiology research. It has been shown that indirect calorimetry systems exhibit differential measurement error, where the error of a device is systematically different depending on the volume of gas flow. Moreover, systems commonly report multiple decimal places of precision, giving the clinician a false sense of device accuracy. The purpose of this manuscript is to demonstrate the use of a novel statistical tool which models the reliability of two specific indirect calorimetry systems, Douglas bag and Parvomedics 2400 TrueOne, as univariate normal distributions and implements the distribution overlapping coefficient to determine the likelihood that two VO(2) measures are the same. A command line implementation of the tool is available for the R programming language as well as a web-based graphical user interface (GUI). This tool is valuable for clinicians performing a single-subject analysis as well as researchers interested in determining if their observed differences exceed the error of the device.
format Online
Article
Text
id pubmed-4863070
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-48630702016-05-30 A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis Tenan, Matthew S. Front Physiol Physiology Indirect calorimetry and oxygen consumption (VO(2)) are accepted tools in human physiology research. It has been shown that indirect calorimetry systems exhibit differential measurement error, where the error of a device is systematically different depending on the volume of gas flow. Moreover, systems commonly report multiple decimal places of precision, giving the clinician a false sense of device accuracy. The purpose of this manuscript is to demonstrate the use of a novel statistical tool which models the reliability of two specific indirect calorimetry systems, Douglas bag and Parvomedics 2400 TrueOne, as univariate normal distributions and implements the distribution overlapping coefficient to determine the likelihood that two VO(2) measures are the same. A command line implementation of the tool is available for the R programming language as well as a web-based graphical user interface (GUI). This tool is valuable for clinicians performing a single-subject analysis as well as researchers interested in determining if their observed differences exceed the error of the device. Frontiers Media S.A. 2016-05-11 /pmc/articles/PMC4863070/ /pubmed/27242546 http://dx.doi.org/10.3389/fphys.2016.00172 Text en Copyright © 2016 Tenan. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Tenan, Matthew S.
A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis
title A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis
title_full A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis
title_fullStr A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis
title_full_unstemmed A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis
title_short A Statistical Method and Tool to Account for Indirect Calorimetry Differential Measurement Error in a Single-Subject Analysis
title_sort statistical method and tool to account for indirect calorimetry differential measurement error in a single-subject analysis
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4863070/
https://www.ncbi.nlm.nih.gov/pubmed/27242546
http://dx.doi.org/10.3389/fphys.2016.00172
work_keys_str_mv AT tenanmatthews astatisticalmethodandtooltoaccountforindirectcalorimetrydifferentialmeasurementerrorinasinglesubjectanalysis
AT tenanmatthews statisticalmethodandtooltoaccountforindirectcalorimetrydifferentialmeasurementerrorinasinglesubjectanalysis