Cargando…
ZOOM or Non-ZOOM? Assessing Spinal Cord Diffusion Tensor Imaging Protocols for Multi-Centre Studies
The purpose of this study was to develop and evaluate two spinal cord (SC) diffusion tensor imaging (DTI) protocols, implemented at multiple sites (using scanners from two different manufacturers), one available on any clinical scanner, and one using more advanced options currently available in the...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4865165/ https://www.ncbi.nlm.nih.gov/pubmed/27171194 http://dx.doi.org/10.1371/journal.pone.0155557 |
_version_ | 1782431743119196160 |
---|---|
author | Samson, Rebecca S. Lévy, Simon Schneider, Torben Smith, Alex K. Smith, Seth A. Cohen-Adad, Julien Gandini Wheeler-Kingshott, Claudia A. M. |
author_facet | Samson, Rebecca S. Lévy, Simon Schneider, Torben Smith, Alex K. Smith, Seth A. Cohen-Adad, Julien Gandini Wheeler-Kingshott, Claudia A. M. |
author_sort | Samson, Rebecca S. |
collection | PubMed |
description | The purpose of this study was to develop and evaluate two spinal cord (SC) diffusion tensor imaging (DTI) protocols, implemented at multiple sites (using scanners from two different manufacturers), one available on any clinical scanner, and one using more advanced options currently available in the research setting, and to use an automated processing method for unbiased quantification. DTI parameters are sensitive to changes in the diseased SC. However, imaging the cord can be technically challenging due to various factors including its small size, patient-related and physiological motion, and field inhomogeneities. Rapid acquisition sequences such as Echo Planar Imaging (EPI) are desirable but may suffer from image distortions. We present a multi-centre comparison of two acquisition protocols implemented on scanners from two different vendors (Siemens and Philips), one using a reduced field-of-view (rFOV) EPI sequence, and one only using options available on standard clinical scanners such as outer volume suppression (OVS). Automatic analysis was performed with the Spinal Cord Toolbox for unbiased and reproducible quantification of DTI metrics in the white matter. Images acquired using the rFOV sequence appear less distorted than those acquired using OVS alone. SC DTI parameter values obtained using both sequences at all sites were consistent with previous measurements made at 3T. For the same scanner manufacturer, DTI parameter inter-site SDs were smaller for the rFOV sequence compared to the OVS sequence. The higher inter-site reproducibility (for the same manufacturer and acquisition details, i.e. ZOOM data acquired at the two Philips sites) of rFOV compared to the OVS sequence supports the idea that making research options such as rFOV more widely available would improve accuracy of measurements obtained in multi-centre clinical trials. Future multi-centre studies should also aim to match the rFOV technique and signal-to-noise ratios in all sequences from different manufacturers/sites in order to avoid any bias in measured DTI parameters and ensure similar sensitivity to pathological changes. |
format | Online Article Text |
id | pubmed-4865165 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-48651652016-05-26 ZOOM or Non-ZOOM? Assessing Spinal Cord Diffusion Tensor Imaging Protocols for Multi-Centre Studies Samson, Rebecca S. Lévy, Simon Schneider, Torben Smith, Alex K. Smith, Seth A. Cohen-Adad, Julien Gandini Wheeler-Kingshott, Claudia A. M. PLoS One Research Article The purpose of this study was to develop and evaluate two spinal cord (SC) diffusion tensor imaging (DTI) protocols, implemented at multiple sites (using scanners from two different manufacturers), one available on any clinical scanner, and one using more advanced options currently available in the research setting, and to use an automated processing method for unbiased quantification. DTI parameters are sensitive to changes in the diseased SC. However, imaging the cord can be technically challenging due to various factors including its small size, patient-related and physiological motion, and field inhomogeneities. Rapid acquisition sequences such as Echo Planar Imaging (EPI) are desirable but may suffer from image distortions. We present a multi-centre comparison of two acquisition protocols implemented on scanners from two different vendors (Siemens and Philips), one using a reduced field-of-view (rFOV) EPI sequence, and one only using options available on standard clinical scanners such as outer volume suppression (OVS). Automatic analysis was performed with the Spinal Cord Toolbox for unbiased and reproducible quantification of DTI metrics in the white matter. Images acquired using the rFOV sequence appear less distorted than those acquired using OVS alone. SC DTI parameter values obtained using both sequences at all sites were consistent with previous measurements made at 3T. For the same scanner manufacturer, DTI parameter inter-site SDs were smaller for the rFOV sequence compared to the OVS sequence. The higher inter-site reproducibility (for the same manufacturer and acquisition details, i.e. ZOOM data acquired at the two Philips sites) of rFOV compared to the OVS sequence supports the idea that making research options such as rFOV more widely available would improve accuracy of measurements obtained in multi-centre clinical trials. Future multi-centre studies should also aim to match the rFOV technique and signal-to-noise ratios in all sequences from different manufacturers/sites in order to avoid any bias in measured DTI parameters and ensure similar sensitivity to pathological changes. Public Library of Science 2016-05-12 /pmc/articles/PMC4865165/ /pubmed/27171194 http://dx.doi.org/10.1371/journal.pone.0155557 Text en © 2016 Samson et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Samson, Rebecca S. Lévy, Simon Schneider, Torben Smith, Alex K. Smith, Seth A. Cohen-Adad, Julien Gandini Wheeler-Kingshott, Claudia A. M. ZOOM or Non-ZOOM? Assessing Spinal Cord Diffusion Tensor Imaging Protocols for Multi-Centre Studies |
title | ZOOM or Non-ZOOM? Assessing Spinal Cord Diffusion Tensor Imaging Protocols for Multi-Centre Studies |
title_full | ZOOM or Non-ZOOM? Assessing Spinal Cord Diffusion Tensor Imaging Protocols for Multi-Centre Studies |
title_fullStr | ZOOM or Non-ZOOM? Assessing Spinal Cord Diffusion Tensor Imaging Protocols for Multi-Centre Studies |
title_full_unstemmed | ZOOM or Non-ZOOM? Assessing Spinal Cord Diffusion Tensor Imaging Protocols for Multi-Centre Studies |
title_short | ZOOM or Non-ZOOM? Assessing Spinal Cord Diffusion Tensor Imaging Protocols for Multi-Centre Studies |
title_sort | zoom or non-zoom? assessing spinal cord diffusion tensor imaging protocols for multi-centre studies |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4865165/ https://www.ncbi.nlm.nih.gov/pubmed/27171194 http://dx.doi.org/10.1371/journal.pone.0155557 |
work_keys_str_mv | AT samsonrebeccas zoomornonzoomassessingspinalcorddiffusiontensorimagingprotocolsformulticentrestudies AT levysimon zoomornonzoomassessingspinalcorddiffusiontensorimagingprotocolsformulticentrestudies AT schneidertorben zoomornonzoomassessingspinalcorddiffusiontensorimagingprotocolsformulticentrestudies AT smithalexk zoomornonzoomassessingspinalcorddiffusiontensorimagingprotocolsformulticentrestudies AT smithsetha zoomornonzoomassessingspinalcorddiffusiontensorimagingprotocolsformulticentrestudies AT cohenadadjulien zoomornonzoomassessingspinalcorddiffusiontensorimagingprotocolsformulticentrestudies AT gandiniwheelerkingshottclaudiaam zoomornonzoomassessingspinalcorddiffusiontensorimagingprotocolsformulticentrestudies |