Cargando…

Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

PURPOSE: Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evo...

Descripción completa

Detalles Bibliográficos
Autores principales: KleinJan, Gijs H., van den Berg, Nynke S., de Jong, Jeroen, Wit, Esther M., Thygessen, Helene, Vegt, Erik, van der Poel, Henk G., van Leeuwen, Fijs W. B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4865539/
https://www.ncbi.nlm.nih.gov/pubmed/26768422
http://dx.doi.org/10.1007/s00259-015-3292-2
_version_ 1782431798882467840
author KleinJan, Gijs H.
van den Berg, Nynke S.
de Jong, Jeroen
Wit, Esther M.
Thygessen, Helene
Vegt, Erik
van der Poel, Henk G.
van Leeuwen, Fijs W. B.
author_facet KleinJan, Gijs H.
van den Berg, Nynke S.
de Jong, Jeroen
Wit, Esther M.
Thygessen, Helene
Vegt, Erik
van der Poel, Henk G.
van Leeuwen, Fijs W. B.
author_sort KleinJan, Gijs H.
collection PubMed
description PURPOSE: Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-(99m)Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. METHODS: The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-(99m)Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. RESULTS: Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs were tumour-positive in 25.4 % of patients (14/55; false-negative rate 7 %, 1/14 patients). In ten patients, the SN was the only tumour-positive LN. Surgical complications were minimal. CONCLUSION: Directly linking 3D preoperative nuclear imaging information on SNs to a robot-integrated fluorescence laparoscope improved the surgeon’s use of the technology and did not influence the sensitivity or morbidity of the procedure. To our surprise, however, the detection rates with the current fluorescence camera did not improve.
format Online
Article
Text
id pubmed-4865539
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-48655392016-05-25 Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery KleinJan, Gijs H. van den Berg, Nynke S. de Jong, Jeroen Wit, Esther M. Thygessen, Helene Vegt, Erik van der Poel, Henk G. van Leeuwen, Fijs W. B. Eur J Nucl Med Mol Imaging Original Article PURPOSE: Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-(99m)Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. METHODS: The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-(99m)Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. RESULTS: Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs were tumour-positive in 25.4 % of patients (14/55; false-negative rate 7 %, 1/14 patients). In ten patients, the SN was the only tumour-positive LN. Surgical complications were minimal. CONCLUSION: Directly linking 3D preoperative nuclear imaging information on SNs to a robot-integrated fluorescence laparoscope improved the surgeon’s use of the technology and did not influence the sensitivity or morbidity of the procedure. To our surprise, however, the detection rates with the current fluorescence camera did not improve. Springer Berlin Heidelberg 2016-01-15 2016 /pmc/articles/PMC4865539/ /pubmed/26768422 http://dx.doi.org/10.1007/s00259-015-3292-2 Text en © The Author(s) 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
KleinJan, Gijs H.
van den Berg, Nynke S.
de Jong, Jeroen
Wit, Esther M.
Thygessen, Helene
Vegt, Erik
van der Poel, Henk G.
van Leeuwen, Fijs W. B.
Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery
title Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery
title_full Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery
title_fullStr Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery
title_full_unstemmed Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery
title_short Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery
title_sort multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4865539/
https://www.ncbi.nlm.nih.gov/pubmed/26768422
http://dx.doi.org/10.1007/s00259-015-3292-2
work_keys_str_mv AT kleinjangijsh multimodalhybridimagingagentsforsentinelnodemappingasameanstoreconnectnuclearmedicinetoadvancesmadeinrobotassistedsurgery
AT vandenbergnynkes multimodalhybridimagingagentsforsentinelnodemappingasameanstoreconnectnuclearmedicinetoadvancesmadeinrobotassistedsurgery
AT dejongjeroen multimodalhybridimagingagentsforsentinelnodemappingasameanstoreconnectnuclearmedicinetoadvancesmadeinrobotassistedsurgery
AT witestherm multimodalhybridimagingagentsforsentinelnodemappingasameanstoreconnectnuclearmedicinetoadvancesmadeinrobotassistedsurgery
AT thygessenhelene multimodalhybridimagingagentsforsentinelnodemappingasameanstoreconnectnuclearmedicinetoadvancesmadeinrobotassistedsurgery
AT vegterik multimodalhybridimagingagentsforsentinelnodemappingasameanstoreconnectnuclearmedicinetoadvancesmadeinrobotassistedsurgery
AT vanderpoelhenkg multimodalhybridimagingagentsforsentinelnodemappingasameanstoreconnectnuclearmedicinetoadvancesmadeinrobotassistedsurgery
AT vanleeuwenfijswb multimodalhybridimagingagentsforsentinelnodemappingasameanstoreconnectnuclearmedicinetoadvancesmadeinrobotassistedsurgery