Cargando…

Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples

Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-...

Descripción completa

Detalles Bibliográficos
Autores principales: Lorenzo, María, Campo, Julián, Picó, Yolanda
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4865636/
https://www.ncbi.nlm.nih.gov/pubmed/27222824
http://dx.doi.org/10.1016/j.mex.2016.04.006
_version_ 1782431811195895808
author Lorenzo, María
Campo, Julián
Picó, Yolanda
author_facet Lorenzo, María
Campo, Julián
Picó, Yolanda
author_sort Lorenzo, María
collection PubMed
description Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-QqQ-MS/MS) has become the most promising platform, already applied successfully for analysis of selected PFRs in some environmental matrices like water and wastewater. However, the presence of some interferences from the dissolvent, the equipment and the used materials should be taken into account. The procedure involves: • The first determination of PFRs by UHPLC-QqQ-MS/MS using a trap column to distinguish the interferences coming from the instrument and mobile phases. • The optimization of the LC separation to distinguish all target compounds and their interferences. • This method coupled to a solid-phase extraction (SPE) improve the detection and quantification of PFRs.
format Online
Article
Text
id pubmed-4865636
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-48656362016-05-24 Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples Lorenzo, María Campo, Julián Picó, Yolanda MethodsX Environmental Science Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-QqQ-MS/MS) has become the most promising platform, already applied successfully for analysis of selected PFRs in some environmental matrices like water and wastewater. However, the presence of some interferences from the dissolvent, the equipment and the used materials should be taken into account. The procedure involves: • The first determination of PFRs by UHPLC-QqQ-MS/MS using a trap column to distinguish the interferences coming from the instrument and mobile phases. • The optimization of the LC separation to distinguish all target compounds and their interferences. • This method coupled to a solid-phase extraction (SPE) improve the detection and quantification of PFRs. Elsevier 2016-04-20 /pmc/articles/PMC4865636/ /pubmed/27222824 http://dx.doi.org/10.1016/j.mex.2016.04.006 Text en © 2016 The Author(s) http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Environmental Science
Lorenzo, María
Campo, Julián
Picó, Yolanda
Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
title Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
title_full Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
title_fullStr Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
title_full_unstemmed Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
title_short Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
title_sort ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
topic Environmental Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4865636/
https://www.ncbi.nlm.nih.gov/pubmed/27222824
http://dx.doi.org/10.1016/j.mex.2016.04.006
work_keys_str_mv AT lorenzomaria ultrahighpressureliquidchromatographytandemmassspectrometrymethodforthedeterminationof9organophosphateflameretardantsinwatersamples
AT campojulian ultrahighpressureliquidchromatographytandemmassspectrometrymethodforthedeterminationof9organophosphateflameretardantsinwatersamples
AT picoyolanda ultrahighpressureliquidchromatographytandemmassspectrometrymethodforthedeterminationof9organophosphateflameretardantsinwatersamples