Cargando…
Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4865636/ https://www.ncbi.nlm.nih.gov/pubmed/27222824 http://dx.doi.org/10.1016/j.mex.2016.04.006 |
_version_ | 1782431811195895808 |
---|---|
author | Lorenzo, María Campo, Julián Picó, Yolanda |
author_facet | Lorenzo, María Campo, Julián Picó, Yolanda |
author_sort | Lorenzo, María |
collection | PubMed |
description | Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-QqQ-MS/MS) has become the most promising platform, already applied successfully for analysis of selected PFRs in some environmental matrices like water and wastewater. However, the presence of some interferences from the dissolvent, the equipment and the used materials should be taken into account. The procedure involves: • The first determination of PFRs by UHPLC-QqQ-MS/MS using a trap column to distinguish the interferences coming from the instrument and mobile phases. • The optimization of the LC separation to distinguish all target compounds and their interferences. • This method coupled to a solid-phase extraction (SPE) improve the detection and quantification of PFRs. |
format | Online Article Text |
id | pubmed-4865636 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-48656362016-05-24 Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples Lorenzo, María Campo, Julián Picó, Yolanda MethodsX Environmental Science Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-QqQ-MS/MS) has become the most promising platform, already applied successfully for analysis of selected PFRs in some environmental matrices like water and wastewater. However, the presence of some interferences from the dissolvent, the equipment and the used materials should be taken into account. The procedure involves: • The first determination of PFRs by UHPLC-QqQ-MS/MS using a trap column to distinguish the interferences coming from the instrument and mobile phases. • The optimization of the LC separation to distinguish all target compounds and their interferences. • This method coupled to a solid-phase extraction (SPE) improve the detection and quantification of PFRs. Elsevier 2016-04-20 /pmc/articles/PMC4865636/ /pubmed/27222824 http://dx.doi.org/10.1016/j.mex.2016.04.006 Text en © 2016 The Author(s) http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Environmental Science Lorenzo, María Campo, Julián Picó, Yolanda Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples |
title | Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples |
title_full | Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples |
title_fullStr | Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples |
title_full_unstemmed | Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples |
title_short | Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples |
title_sort | ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples |
topic | Environmental Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4865636/ https://www.ncbi.nlm.nih.gov/pubmed/27222824 http://dx.doi.org/10.1016/j.mex.2016.04.006 |
work_keys_str_mv | AT lorenzomaria ultrahighpressureliquidchromatographytandemmassspectrometrymethodforthedeterminationof9organophosphateflameretardantsinwatersamples AT campojulian ultrahighpressureliquidchromatographytandemmassspectrometrymethodforthedeterminationof9organophosphateflameretardantsinwatersamples AT picoyolanda ultrahighpressureliquidchromatographytandemmassspectrometrymethodforthedeterminationof9organophosphateflameretardantsinwatersamples |