Cargando…
Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio
Purpose The aim of this paper is to demonstrate fundamental photographic techniques and standardized views in oculoplastic disease and surgery outside of a photographic studio. Methods A Canon EOS 60D digital single lens reflex (DSLR) camera, which was fitted with a Canon EF-S 60 mm USM macro lens,...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4866870/ https://www.ncbi.nlm.nih.gov/pubmed/27186451 http://dx.doi.org/10.7759/cureus.569 |
_version_ | 1782431981823328256 |
---|---|
author | Ong, Chin T Kalantzis, George Yap, Jun Fai Chang, Bernard |
author_facet | Ong, Chin T Kalantzis, George Yap, Jun Fai Chang, Bernard |
author_sort | Ong, Chin T |
collection | PubMed |
description | Purpose The aim of this paper is to demonstrate fundamental photographic techniques and standardized views in oculoplastic disease and surgery outside of a photographic studio. Methods A Canon EOS 60D digital single lens reflex (DSLR) camera, which was fitted with a Canon EF-S 60 mm USM macro lens, was used to photograph the subject. A Canon MR-14EX Macro Ringlite was used to illuminate the subject. Informed written consent was obtained for publication of the photographs used in this study. The photographs were taken in an ophthalmology clinic using standardized photographic settings at various magnification ratios. The magnification ratios were recalibrated and adjusted to accommodate the smaller sensor size in-line with standardized medical photography guidelines. Results We present a series of core views for various oculoplastic and orbital disease presentations. Conclusions It is possible to capture quality standardized digital photographs in a busy clinical environment without the need for a dedicated photographic studio. |
format | Online Article Text |
id | pubmed-4866870 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-48668702016-05-16 Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio Ong, Chin T Kalantzis, George Yap, Jun Fai Chang, Bernard Cureus Ophthalmology Purpose The aim of this paper is to demonstrate fundamental photographic techniques and standardized views in oculoplastic disease and surgery outside of a photographic studio. Methods A Canon EOS 60D digital single lens reflex (DSLR) camera, which was fitted with a Canon EF-S 60 mm USM macro lens, was used to photograph the subject. A Canon MR-14EX Macro Ringlite was used to illuminate the subject. Informed written consent was obtained for publication of the photographs used in this study. The photographs were taken in an ophthalmology clinic using standardized photographic settings at various magnification ratios. The magnification ratios were recalibrated and adjusted to accommodate the smaller sensor size in-line with standardized medical photography guidelines. Results We present a series of core views for various oculoplastic and orbital disease presentations. Conclusions It is possible to capture quality standardized digital photographs in a busy clinical environment without the need for a dedicated photographic studio. Cureus 2016-04-13 /pmc/articles/PMC4866870/ /pubmed/27186451 http://dx.doi.org/10.7759/cureus.569 Text en Copyright © 2016, Ong et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Ophthalmology Ong, Chin T Kalantzis, George Yap, Jun Fai Chang, Bernard Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio |
title | Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio |
title_full | Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio |
title_fullStr | Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio |
title_full_unstemmed | Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio |
title_short | Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio |
title_sort | standardized photographic views in oculoplastic surgery: how to capture quality images outside a photographic studio |
topic | Ophthalmology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4866870/ https://www.ncbi.nlm.nih.gov/pubmed/27186451 http://dx.doi.org/10.7759/cureus.569 |
work_keys_str_mv | AT ongchint standardizedphotographicviewsinoculoplasticsurgeryhowtocapturequalityimagesoutsideaphotographicstudio AT kalantzisgeorge standardizedphotographicviewsinoculoplasticsurgeryhowtocapturequalityimagesoutsideaphotographicstudio AT yapjunfai standardizedphotographicviewsinoculoplasticsurgeryhowtocapturequalityimagesoutsideaphotographicstudio AT changbernard standardizedphotographicviewsinoculoplasticsurgeryhowtocapturequalityimagesoutsideaphotographicstudio |