Cargando…

Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio

Purpose The aim of this paper is to demonstrate fundamental photographic techniques and standardized views in oculoplastic disease and surgery outside of a photographic studio. Methods A Canon EOS 60D digital single lens reflex (DSLR) camera, which was fitted with a Canon EF-S 60 mm USM macro lens,...

Descripción completa

Detalles Bibliográficos
Autores principales: Ong, Chin T, Kalantzis, George, Yap, Jun Fai, Chang, Bernard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4866870/
https://www.ncbi.nlm.nih.gov/pubmed/27186451
http://dx.doi.org/10.7759/cureus.569
_version_ 1782431981823328256
author Ong, Chin T
Kalantzis, George
Yap, Jun Fai
Chang, Bernard
author_facet Ong, Chin T
Kalantzis, George
Yap, Jun Fai
Chang, Bernard
author_sort Ong, Chin T
collection PubMed
description Purpose The aim of this paper is to demonstrate fundamental photographic techniques and standardized views in oculoplastic disease and surgery outside of a photographic studio. Methods A Canon EOS 60D digital single lens reflex (DSLR) camera, which was fitted with a Canon EF-S 60 mm USM macro lens, was used to photograph the subject. A Canon MR-14EX Macro Ringlite was used to illuminate the subject. Informed written consent was obtained for publication of the photographs used in this study. The photographs were taken in an ophthalmology clinic using standardized photographic settings at various magnification ratios. The magnification ratios were recalibrated and adjusted to accommodate the smaller sensor size in-line with standardized medical photography guidelines. Results We present a series of core views for various oculoplastic and orbital disease presentations. Conclusions It is possible to capture quality standardized digital photographs in a busy clinical environment without the need for a dedicated photographic studio.
format Online
Article
Text
id pubmed-4866870
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-48668702016-05-16 Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio Ong, Chin T Kalantzis, George Yap, Jun Fai Chang, Bernard Cureus Ophthalmology Purpose The aim of this paper is to demonstrate fundamental photographic techniques and standardized views in oculoplastic disease and surgery outside of a photographic studio. Methods A Canon EOS 60D digital single lens reflex (DSLR) camera, which was fitted with a Canon EF-S 60 mm USM macro lens, was used to photograph the subject. A Canon MR-14EX Macro Ringlite was used to illuminate the subject. Informed written consent was obtained for publication of the photographs used in this study. The photographs were taken in an ophthalmology clinic using standardized photographic settings at various magnification ratios. The magnification ratios were recalibrated and adjusted to accommodate the smaller sensor size in-line with standardized medical photography guidelines. Results We present a series of core views for various oculoplastic and orbital disease presentations. Conclusions It is possible to capture quality standardized digital photographs in a busy clinical environment without the need for a dedicated photographic studio. Cureus 2016-04-13 /pmc/articles/PMC4866870/ /pubmed/27186451 http://dx.doi.org/10.7759/cureus.569 Text en Copyright © 2016, Ong et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Ophthalmology
Ong, Chin T
Kalantzis, George
Yap, Jun Fai
Chang, Bernard
Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio
title Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio
title_full Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio
title_fullStr Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio
title_full_unstemmed Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio
title_short Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio
title_sort standardized photographic views in oculoplastic surgery: how to capture quality images outside a photographic studio
topic Ophthalmology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4866870/
https://www.ncbi.nlm.nih.gov/pubmed/27186451
http://dx.doi.org/10.7759/cureus.569
work_keys_str_mv AT ongchint standardizedphotographicviewsinoculoplasticsurgeryhowtocapturequalityimagesoutsideaphotographicstudio
AT kalantzisgeorge standardizedphotographicviewsinoculoplasticsurgeryhowtocapturequalityimagesoutsideaphotographicstudio
AT yapjunfai standardizedphotographicviewsinoculoplasticsurgeryhowtocapturequalityimagesoutsideaphotographicstudio
AT changbernard standardizedphotographicviewsinoculoplasticsurgeryhowtocapturequalityimagesoutsideaphotographicstudio