Cargando…
Pixel-level plasmonic microcavity infrared photodetector
Recently, plasmonics has been central to the manipulation of photons on the subwavelength scale, and superior infrared imagers have opened novel applications in many fields. Here, we demonstrate the first pixel-level plasmonic microcavity infrared photodetector with a single quantum well integrated...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4867604/ https://www.ncbi.nlm.nih.gov/pubmed/27181111 http://dx.doi.org/10.1038/srep25849 |
_version_ | 1782432051298828288 |
---|---|
author | Jing, You Liang Li, Zhi Feng Li, Qian Chen, Xiao Shuang Chen, Ping Ping Wang, Han Li, Meng Yao Li, Ning Lu, Wei |
author_facet | Jing, You Liang Li, Zhi Feng Li, Qian Chen, Xiao Shuang Chen, Ping Ping Wang, Han Li, Meng Yao Li, Ning Lu, Wei |
author_sort | Jing, You Liang |
collection | PubMed |
description | Recently, plasmonics has been central to the manipulation of photons on the subwavelength scale, and superior infrared imagers have opened novel applications in many fields. Here, we demonstrate the first pixel-level plasmonic microcavity infrared photodetector with a single quantum well integrated between metal patches and a reflection layer. Greater than one order of magnitude enhancement of the peak responsivity has been observed. The significant improvement originates from the highly confined optical mode in the cavity, leading to a strong coupling between photons and the quantum well, resulting in the enhanced photo-electric conversion process. Such strong coupling from the localized surface plasmon mode inside the cavity is independent of incident angles, offering a unique solution to high-performance focal plane array devices. This demonstration paves the way for important infrared optoelectronic devices for sensing and imaging. |
format | Online Article Text |
id | pubmed-4867604 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-48676042016-05-31 Pixel-level plasmonic microcavity infrared photodetector Jing, You Liang Li, Zhi Feng Li, Qian Chen, Xiao Shuang Chen, Ping Ping Wang, Han Li, Meng Yao Li, Ning Lu, Wei Sci Rep Article Recently, plasmonics has been central to the manipulation of photons on the subwavelength scale, and superior infrared imagers have opened novel applications in many fields. Here, we demonstrate the first pixel-level plasmonic microcavity infrared photodetector with a single quantum well integrated between metal patches and a reflection layer. Greater than one order of magnitude enhancement of the peak responsivity has been observed. The significant improvement originates from the highly confined optical mode in the cavity, leading to a strong coupling between photons and the quantum well, resulting in the enhanced photo-electric conversion process. Such strong coupling from the localized surface plasmon mode inside the cavity is independent of incident angles, offering a unique solution to high-performance focal plane array devices. This demonstration paves the way for important infrared optoelectronic devices for sensing and imaging. Nature Publishing Group 2016-05-16 /pmc/articles/PMC4867604/ /pubmed/27181111 http://dx.doi.org/10.1038/srep25849 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Jing, You Liang Li, Zhi Feng Li, Qian Chen, Xiao Shuang Chen, Ping Ping Wang, Han Li, Meng Yao Li, Ning Lu, Wei Pixel-level plasmonic microcavity infrared photodetector |
title | Pixel-level plasmonic microcavity infrared photodetector |
title_full | Pixel-level plasmonic microcavity infrared photodetector |
title_fullStr | Pixel-level plasmonic microcavity infrared photodetector |
title_full_unstemmed | Pixel-level plasmonic microcavity infrared photodetector |
title_short | Pixel-level plasmonic microcavity infrared photodetector |
title_sort | pixel-level plasmonic microcavity infrared photodetector |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4867604/ https://www.ncbi.nlm.nih.gov/pubmed/27181111 http://dx.doi.org/10.1038/srep25849 |
work_keys_str_mv | AT jingyouliang pixellevelplasmonicmicrocavityinfraredphotodetector AT lizhifeng pixellevelplasmonicmicrocavityinfraredphotodetector AT liqian pixellevelplasmonicmicrocavityinfraredphotodetector AT chenxiaoshuang pixellevelplasmonicmicrocavityinfraredphotodetector AT chenpingping pixellevelplasmonicmicrocavityinfraredphotodetector AT wanghan pixellevelplasmonicmicrocavityinfraredphotodetector AT limengyao pixellevelplasmonicmicrocavityinfraredphotodetector AT lining pixellevelplasmonicmicrocavityinfraredphotodetector AT luwei pixellevelplasmonicmicrocavityinfraredphotodetector |