Reliability of lower leg proximal end and forefoot kinematics during different paces of barefoot racewalking on a treadmill using a motion recorder (MVP-RF8-BC)

[Purpose] This study was performed to investigate the changes in lower leg proximal end and forefoot kinematics, and reliability of measurement during different paces of barefoot racewalking on treadmill. [Subjects] Eleven junior racewalking men participated in this study. [Methods] To identify chan...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Hongzhao, Huo, Ming, An, Xiangde, Li, Yong, Onoda, Ko, Li, Desheng, Huang, Qiuchen, Maruyama, Hitoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Society of Physical Therapy Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4868205/
https://www.ncbi.nlm.nih.gov/pubmed/27190445
http://dx.doi.org/10.1589/jpts.28.1155
_version_ 1782432145342464000
author Wang, Hongzhao
Huo, Ming
An, Xiangde
Li, Yong
Onoda, Ko
Li, Desheng
Huang, Qiuchen
Maruyama, Hitoshi
author_facet Wang, Hongzhao
Huo, Ming
An, Xiangde
Li, Yong
Onoda, Ko
Li, Desheng
Huang, Qiuchen
Maruyama, Hitoshi
author_sort Wang, Hongzhao
collection PubMed
description [Purpose] This study was performed to investigate the changes in lower leg proximal end and forefoot kinematics, and reliability of measurement during different paces of barefoot racewalking on treadmill. [Subjects] Eleven junior racewalking men participated in this study. [Methods] To identify changes in lower leg proximal end and forefoot kinematics, during different paces of barefoot racewalking on a treadmill, a wireless motion recorder (MVP-RF8-BC) was used. Interclass correlation coefficients (ICC 1, 2) were used to estimate reliability. [Results] There were significant differences in the lower leg proximal end and forefoot maximum medial/lateral rotations at a pace of 9 km/h compared with those at a pace of 5 km/h pace. The intra-examiner reliability estimates ranged from 0.82 and 0.89 to 0.87 and 0.93 for lower leg proximal end inversion/eversion rotation and medial/lateral rotation, and from 0.92 and 0.84 to 0.93 and 0.91 for forefoot inversion/eversion rotation and medial/lateral rotation. [Conclusion] We conclude that the lower leg proximal end and forefoot kinematics of barefoot racewalking on a treadmill are influenced by different paces and that assessment of lower leg proximal end and forefoot kinematics by means of the wireless motion recorder (MVP-RF8-BC) is adequately reliable. This information may be useful for determining exercise prescriptions.
format Online
Article
Text
id pubmed-4868205
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Society of Physical Therapy Science
record_format MEDLINE/PubMed
spelling pubmed-48682052016-05-17 Reliability of lower leg proximal end and forefoot kinematics during different paces of barefoot racewalking on a treadmill using a motion recorder (MVP-RF8-BC) Wang, Hongzhao Huo, Ming An, Xiangde Li, Yong Onoda, Ko Li, Desheng Huang, Qiuchen Maruyama, Hitoshi J Phys Ther Sci Original Article [Purpose] This study was performed to investigate the changes in lower leg proximal end and forefoot kinematics, and reliability of measurement during different paces of barefoot racewalking on treadmill. [Subjects] Eleven junior racewalking men participated in this study. [Methods] To identify changes in lower leg proximal end and forefoot kinematics, during different paces of barefoot racewalking on a treadmill, a wireless motion recorder (MVP-RF8-BC) was used. Interclass correlation coefficients (ICC 1, 2) were used to estimate reliability. [Results] There were significant differences in the lower leg proximal end and forefoot maximum medial/lateral rotations at a pace of 9 km/h compared with those at a pace of 5 km/h pace. The intra-examiner reliability estimates ranged from 0.82 and 0.89 to 0.87 and 0.93 for lower leg proximal end inversion/eversion rotation and medial/lateral rotation, and from 0.92 and 0.84 to 0.93 and 0.91 for forefoot inversion/eversion rotation and medial/lateral rotation. [Conclusion] We conclude that the lower leg proximal end and forefoot kinematics of barefoot racewalking on a treadmill are influenced by different paces and that assessment of lower leg proximal end and forefoot kinematics by means of the wireless motion recorder (MVP-RF8-BC) is adequately reliable. This information may be useful for determining exercise prescriptions. The Society of Physical Therapy Science 2016-04-28 2016-04 /pmc/articles/PMC4868205/ /pubmed/27190445 http://dx.doi.org/10.1589/jpts.28.1155 Text en 2016©by the Society of Physical Therapy Science. Published by IPEC Inc. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License.
spellingShingle Original Article
Wang, Hongzhao
Huo, Ming
An, Xiangde
Li, Yong
Onoda, Ko
Li, Desheng
Huang, Qiuchen
Maruyama, Hitoshi
Reliability of lower leg proximal end and forefoot kinematics during different paces of barefoot racewalking on a treadmill using a motion recorder (MVP-RF8-BC)
title Reliability of lower leg proximal end and forefoot kinematics during different paces of barefoot racewalking on a treadmill using a motion recorder (MVP-RF8-BC)
title_full Reliability of lower leg proximal end and forefoot kinematics during different paces of barefoot racewalking on a treadmill using a motion recorder (MVP-RF8-BC)
title_fullStr Reliability of lower leg proximal end and forefoot kinematics during different paces of barefoot racewalking on a treadmill using a motion recorder (MVP-RF8-BC)
title_full_unstemmed Reliability of lower leg proximal end and forefoot kinematics during different paces of barefoot racewalking on a treadmill using a motion recorder (MVP-RF8-BC)
title_short Reliability of lower leg proximal end and forefoot kinematics during different paces of barefoot racewalking on a treadmill using a motion recorder (MVP-RF8-BC)
title_sort reliability of lower leg proximal end and forefoot kinematics during different paces of barefoot racewalking on a treadmill using a motion recorder (mvp-rf8-bc)
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4868205/
https://www.ncbi.nlm.nih.gov/pubmed/27190445
http://dx.doi.org/10.1589/jpts.28.1155
work_keys_str_mv AT wanghongzhao reliabilityoflowerlegproximalendandforefootkinematicsduringdifferentpacesofbarefootracewalkingonatreadmillusingamotionrecordermvprf8bc
AT huoming reliabilityoflowerlegproximalendandforefootkinematicsduringdifferentpacesofbarefootracewalkingonatreadmillusingamotionrecordermvprf8bc
AT anxiangde reliabilityoflowerlegproximalendandforefootkinematicsduringdifferentpacesofbarefootracewalkingonatreadmillusingamotionrecordermvprf8bc
AT liyong reliabilityoflowerlegproximalendandforefootkinematicsduringdifferentpacesofbarefootracewalkingonatreadmillusingamotionrecordermvprf8bc
AT onodako reliabilityoflowerlegproximalendandforefootkinematicsduringdifferentpacesofbarefootracewalkingonatreadmillusingamotionrecordermvprf8bc
AT lidesheng reliabilityoflowerlegproximalendandforefootkinematicsduringdifferentpacesofbarefootracewalkingonatreadmillusingamotionrecordermvprf8bc
AT huangqiuchen reliabilityoflowerlegproximalendandforefootkinematicsduringdifferentpacesofbarefootracewalkingonatreadmillusingamotionrecordermvprf8bc
AT maruyamahitoshi reliabilityoflowerlegproximalendandforefootkinematicsduringdifferentpacesofbarefootracewalkingonatreadmillusingamotionrecordermvprf8bc