In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection

Background and Aim. The geometry of implant-abutment interface (IAI) affects the risk of bacterial leakage and invasion into the internal parts of the implant. The aim of this study was to compare the bacterial leakage of an 11-degree Morse taper IAI with that of a butt joint connection. Materials a...

Descripción completa

Detalles Bibliográficos
Autores principales: Khorshidi, Hooman, Raoofi, Saeed, Moattari, Afagh, Bagheri, Atoosa, Kalantari, Mohammad Hassan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4868898/
https://www.ncbi.nlm.nih.gov/pubmed/27242903
http://dx.doi.org/10.1155/2016/8527849
_version_ 1782432223999295488
author Khorshidi, Hooman
Raoofi, Saeed
Moattari, Afagh
Bagheri, Atoosa
Kalantari, Mohammad Hassan
author_facet Khorshidi, Hooman
Raoofi, Saeed
Moattari, Afagh
Bagheri, Atoosa
Kalantari, Mohammad Hassan
author_sort Khorshidi, Hooman
collection PubMed
description Background and Aim. The geometry of implant-abutment interface (IAI) affects the risk of bacterial leakage and invasion into the internal parts of the implant. The aim of this study was to compare the bacterial leakage of an 11-degree Morse taper IAI with that of a butt joint connection. Materials and Methods. Two implants systems were tested (n = 10 per group): CSM (submerged) and TBR (connect). The deepest inner parts of the implants were inoculated with 2 μL of Streptococcus mutans suspension with a concentration of 108 CFU/mL. The abutments were tightened on the implants. The specimens were stored in the incubator at a temperature of 37°C for 14 days and the penetration of the bacterium in the surrounding area was determined by the observation of the solution turbidity and comparison with control specimens. Kaplan-Meier survival curve was traced for the estimation of bacterial leakage and the results between two groups of implants were statistically analyzed by chi-square test. Results. No case of the implant system with the internal conical connection design revealed bacterial leakage in 14 days and no turbidity of the solution was reported for it. In the system with butt joint implant-abutment connection, 1 case showed leakage on the third day, 1 case on the eighth day, and 5 cases on the 13th day. In total, 7 (70%) cases showed bacterial leakage in this system. Significant differences were found between the two groups of implants based on the incidence of bacterial leakage (p < 0.05). Conclusion. The 11-degree Morse taper demonstrated better resistance to microbial leakage than butt joint connection.
format Online
Article
Text
id pubmed-4868898
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-48688982016-05-30 In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection Khorshidi, Hooman Raoofi, Saeed Moattari, Afagh Bagheri, Atoosa Kalantari, Mohammad Hassan Int J Biomater Research Article Background and Aim. The geometry of implant-abutment interface (IAI) affects the risk of bacterial leakage and invasion into the internal parts of the implant. The aim of this study was to compare the bacterial leakage of an 11-degree Morse taper IAI with that of a butt joint connection. Materials and Methods. Two implants systems were tested (n = 10 per group): CSM (submerged) and TBR (connect). The deepest inner parts of the implants were inoculated with 2 μL of Streptococcus mutans suspension with a concentration of 108 CFU/mL. The abutments were tightened on the implants. The specimens were stored in the incubator at a temperature of 37°C for 14 days and the penetration of the bacterium in the surrounding area was determined by the observation of the solution turbidity and comparison with control specimens. Kaplan-Meier survival curve was traced for the estimation of bacterial leakage and the results between two groups of implants were statistically analyzed by chi-square test. Results. No case of the implant system with the internal conical connection design revealed bacterial leakage in 14 days and no turbidity of the solution was reported for it. In the system with butt joint implant-abutment connection, 1 case showed leakage on the third day, 1 case on the eighth day, and 5 cases on the 13th day. In total, 7 (70%) cases showed bacterial leakage in this system. Significant differences were found between the two groups of implants based on the incidence of bacterial leakage (p < 0.05). Conclusion. The 11-degree Morse taper demonstrated better resistance to microbial leakage than butt joint connection. Hindawi Publishing Corporation 2016 2016-05-03 /pmc/articles/PMC4868898/ /pubmed/27242903 http://dx.doi.org/10.1155/2016/8527849 Text en Copyright © 2016 Hooman Khorshidi et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Khorshidi, Hooman
Raoofi, Saeed
Moattari, Afagh
Bagheri, Atoosa
Kalantari, Mohammad Hassan
In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection
title In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection
title_full In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection
title_fullStr In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection
title_full_unstemmed In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection
title_short In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection
title_sort in vitro evaluation of bacterial leakage at implant-abutment connection: an 11-degree morse taper compared to a butt joint connection
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4868898/
https://www.ncbi.nlm.nih.gov/pubmed/27242903
http://dx.doi.org/10.1155/2016/8527849
work_keys_str_mv AT khorshidihooman invitroevaluationofbacterialleakageatimplantabutmentconnectionan11degreemorsetapercomparedtoabuttjointconnection
AT raoofisaeed invitroevaluationofbacterialleakageatimplantabutmentconnectionan11degreemorsetapercomparedtoabuttjointconnection
AT moattariafagh invitroevaluationofbacterialleakageatimplantabutmentconnectionan11degreemorsetapercomparedtoabuttjointconnection
AT bagheriatoosa invitroevaluationofbacterialleakageatimplantabutmentconnectionan11degreemorsetapercomparedtoabuttjointconnection
AT kalantarimohammadhassan invitroevaluationofbacterialleakageatimplantabutmentconnectionan11degreemorsetapercomparedtoabuttjointconnection